Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare

Objective: In this paper, we aim to report our experience in percutaneous ureteral stent retrieval using a loop snare under fluoroscopic guidance and to assess the efficacy and safety of the method. Materials and Methods: Between February 2009 and December 2016, electronic records of the patients wh...

Full description

Bibliographic Details
Main Authors: Güven Kahriman, Nevzat Özcan, Aytaç Doğan
Format: Article
Language:English
Published: KARE Publishing 2019-11-01
Series:Erciyes Medical Journal
Subjects:
Online Access:https://jag.journalagent.com/z4/download_fulltext.asp?pdir=erciyesmedj&un=EMJ-24654
_version_ 1797923964065939456
author Güven Kahriman
Nevzat Özcan
Aytaç Doğan
author_facet Güven Kahriman
Nevzat Özcan
Aytaç Doğan
author_sort Güven Kahriman
collection DOAJ
description Objective: In this paper, we aim to report our experience in percutaneous ureteral stent retrieval using a loop snare under fluoroscopic guidance and to assess the efficacy and safety of the method. Materials and Methods: Between February 2009 and December 2016, electronic records of the patients who underwent percutaneous ureteral stent retrieval were reviewed. A total of 12 patients (8 males, 4 females; age range, 6 months–75 years; mean age, 39.71+-32.3 [standard deviation] years) were included in the study. A loop snare was used to retrieve the ureteral stent from the calyx, renal pelvis, and upper or distal ureters via the vascular sheath. The stent retrieval was performed for endoscopic failure (n=5), proximal stent migration (n=3), early occlusion of the stent (n=2), and stent fragmentation (n=2). A complete percutaneous removal of the ureteral stent with the snare was considered a technical success. Results: Our technical success rate was 100%. There were no major complications. One patient (8.3%) had minor hematuria that resolved spontaneously. Conclusion: Percutaneous ureteral stent retrieval using a loop snare under fluoroscopic guidance is a safe and effective procedure, especially when the cystoscopic removal has failed and stent-related complications occurred.
first_indexed 2024-04-10T14:54:19Z
format Article
id doaj.art-4b877fb7dfb742f3a436e4e3ab114ebf
institution Directory Open Access Journal
issn 2149-2247
language English
last_indexed 2024-04-10T14:54:19Z
publishDate 2019-11-01
publisher KARE Publishing
record_format Article
series Erciyes Medical Journal
spelling doaj.art-4b877fb7dfb742f3a436e4e3ab114ebf2023-02-15T16:07:26ZengKARE PublishingErciyes Medical Journal2149-22472019-11-0141444044310.14744/etd.2019.24654EMJ-24654Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a SnareGüven Kahriman0Nevzat Özcan1Aytaç Doğan2Department of Radiology, Erciyes University Faculty of Medicine, Gevher Nesibe Hospital, Kayseri, TurkeyDepartment of Radiology, Erciyes University Faculty of Medicine, Gevher Nesibe Hospital, Kayseri, TurkeyDepartment of Radiology, Erciyes University Faculty of Medicine, Gevher Nesibe Hospital, Kayseri, TurkeyObjective: In this paper, we aim to report our experience in percutaneous ureteral stent retrieval using a loop snare under fluoroscopic guidance and to assess the efficacy and safety of the method. Materials and Methods: Between February 2009 and December 2016, electronic records of the patients who underwent percutaneous ureteral stent retrieval were reviewed. A total of 12 patients (8 males, 4 females; age range, 6 months–75 years; mean age, 39.71+-32.3 [standard deviation] years) were included in the study. A loop snare was used to retrieve the ureteral stent from the calyx, renal pelvis, and upper or distal ureters via the vascular sheath. The stent retrieval was performed for endoscopic failure (n=5), proximal stent migration (n=3), early occlusion of the stent (n=2), and stent fragmentation (n=2). A complete percutaneous removal of the ureteral stent with the snare was considered a technical success. Results: Our technical success rate was 100%. There were no major complications. One patient (8.3%) had minor hematuria that resolved spontaneously. Conclusion: Percutaneous ureteral stent retrieval using a loop snare under fluoroscopic guidance is a safe and effective procedure, especially when the cystoscopic removal has failed and stent-related complications occurred.https://jag.journalagent.com/z4/download_fulltext.asp?pdir=erciyesmedj&un=EMJ-24654stentsureterfluoroscopypercutaneous nephrostomy.
spellingShingle Güven Kahriman
Nevzat Özcan
Aytaç Doğan
Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare
Erciyes Medical Journal
stents
ureter
fluoroscopy
percutaneous nephrostomy.
title Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare
title_full Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare
title_fullStr Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare
title_full_unstemmed Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare
title_short Percutaneous Retrieval of Internal Double-J Ureteral Stents Using a Snare
title_sort percutaneous retrieval of internal double j ureteral stents using a snare
topic stents
ureter
fluoroscopy
percutaneous nephrostomy.
url https://jag.journalagent.com/z4/download_fulltext.asp?pdir=erciyesmedj&un=EMJ-24654
work_keys_str_mv AT guvenkahriman percutaneousretrievalofinternaldoublejureteralstentsusingasnare
AT nevzatozcan percutaneousretrievalofinternaldoublejureteralstentsusingasnare
AT aytacdogan percutaneousretrievalofinternaldoublejureteralstentsusingasnare