Development and validation of an HPLC method for stability evaluation of nystatin

A liquid chromatography method for evaluating the stability of Nystatin (Nys) in an ointment was developed and validated, since the traditional pharmacopeial microbiological methods are unable to indicate stability. The stress experiments showed that Nys was found to significantly degrade in alkalin...

Full description

Bibliographic Details
Main Authors: Ana Paola Prata Cione, Márcio José Liberale, Paulo Marcos da Silva
Format: Article
Language:English
Published: Universidade de São Paulo 2010-06-01
Series:Brazilian Journal of Pharmaceutical Sciences
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000200018
_version_ 1811330257308876800
author Ana Paola Prata Cione
Márcio José Liberale
Paulo Marcos da Silva
author_facet Ana Paola Prata Cione
Márcio José Liberale
Paulo Marcos da Silva
author_sort Ana Paola Prata Cione
collection DOAJ
description A liquid chromatography method for evaluating the stability of Nystatin (Nys) in an ointment was developed and validated, since the traditional pharmacopeial microbiological methods are unable to indicate stability. The stress experiments showed that Nys was found to significantly degrade in alkaline and acidic conditions and also under oxidative stress. Lower levels of degradation were detected under heat and with the sample exposed to Xenon light. Resolutions higher than 2 for Nys and degradation products (DP) chromatographic peaks were achieved by using an Inerstil ODS-3 column, isocratic elution with methanol:water and UV detection at 305 nm. The system was found to be linear over a range of 102 to 310 IU mL-1 and proved precise, since the RSD(%) was 0.24% for the six replicates tested. The method also exhibited good levels of recovery (from 98.24% to 100.74%). Therefore, the validation fulfilled pharmacopeial requirements and the procedure was found to be reliable, precise, accurate and selective for determination of Nys and its degradation products.<br>Um método indicador de estabilidade por cromatografia líquida foi desenvolvido e validado para a análise de Nistatina (Nys) em uma pomada, uma vez que os métodos microbiológicos tradicionais não têm a habilidade de serem indicadores de estabilidade. A nistatina degradou significativamente em condições alcalinas e ácidas e também em meio oxidante. Quando a amostra foi exposta a luz de xenônio, foram observados menores níveis de degradação. A resolução entre os picos cromatográficos de Nys e seus produtos de degradação (PD) foi maior que 2, utilizando-se uma coluna Inerstil ODS-3, eluição isocrática com metanol: água e detecção no UV em 305 nm. O sistema foi linear entre a faixa de 102 a 310 UI mL-1 e preciso uma vez que o DPR(%) foi de 0,24% entre as seis replicatas testadas. Além disso, o método exibiu bons níveis de recuperação (de 98,24% a 100,74%). Consequentemente, considera-se que a validação atendeu a todos os requisitos farmacopêicos e o método pode ser considerado confiável, preciso, exato e seletivo para determinação de Nys e seus produtos de degradação.
first_indexed 2024-04-13T15:59:21Z
format Article
id doaj.art-4b91a8ebe33b48369c6ac8c0401246d3
institution Directory Open Access Journal
issn 1984-8250
2175-9790
language English
last_indexed 2024-04-13T15:59:21Z
publishDate 2010-06-01
publisher Universidade de São Paulo
record_format Article
series Brazilian Journal of Pharmaceutical Sciences
spelling doaj.art-4b91a8ebe33b48369c6ac8c0401246d32022-12-22T02:40:35ZengUniversidade de São PauloBrazilian Journal of Pharmaceutical Sciences1984-82502175-97902010-06-0146230531010.1590/S1984-82502010000200018Development and validation of an HPLC method for stability evaluation of nystatinAna Paola Prata CioneMárcio José LiberalePaulo Marcos da SilvaA liquid chromatography method for evaluating the stability of Nystatin (Nys) in an ointment was developed and validated, since the traditional pharmacopeial microbiological methods are unable to indicate stability. The stress experiments showed that Nys was found to significantly degrade in alkaline and acidic conditions and also under oxidative stress. Lower levels of degradation were detected under heat and with the sample exposed to Xenon light. Resolutions higher than 2 for Nys and degradation products (DP) chromatographic peaks were achieved by using an Inerstil ODS-3 column, isocratic elution with methanol:water and UV detection at 305 nm. The system was found to be linear over a range of 102 to 310 IU mL-1 and proved precise, since the RSD(%) was 0.24% for the six replicates tested. The method also exhibited good levels of recovery (from 98.24% to 100.74%). Therefore, the validation fulfilled pharmacopeial requirements and the procedure was found to be reliable, precise, accurate and selective for determination of Nys and its degradation products.<br>Um método indicador de estabilidade por cromatografia líquida foi desenvolvido e validado para a análise de Nistatina (Nys) em uma pomada, uma vez que os métodos microbiológicos tradicionais não têm a habilidade de serem indicadores de estabilidade. A nistatina degradou significativamente em condições alcalinas e ácidas e também em meio oxidante. Quando a amostra foi exposta a luz de xenônio, foram observados menores níveis de degradação. A resolução entre os picos cromatográficos de Nys e seus produtos de degradação (PD) foi maior que 2, utilizando-se uma coluna Inerstil ODS-3, eluição isocrática com metanol: água e detecção no UV em 305 nm. O sistema foi linear entre a faixa de 102 a 310 UI mL-1 e preciso uma vez que o DPR(%) foi de 0,24% entre as seis replicatas testadas. Além disso, o método exibiu bons níveis de recuperação (de 98,24% a 100,74%). Consequentemente, considera-se que a validação atendeu a todos os requisitos farmacopêicos e o método pode ser considerado confiável, preciso, exato e seletivo para determinação de Nys e seus produtos de degradação.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000200018NistatinaDegradação forçadaCromatografia líquida de alta eficiênciaNystatinForced degradationHigh performance liquid chromatography
spellingShingle Ana Paola Prata Cione
Márcio José Liberale
Paulo Marcos da Silva
Development and validation of an HPLC method for stability evaluation of nystatin
Brazilian Journal of Pharmaceutical Sciences
Nistatina
Degradação forçada
Cromatografia líquida de alta eficiência
Nystatin
Forced degradation
High performance liquid chromatography
title Development and validation of an HPLC method for stability evaluation of nystatin
title_full Development and validation of an HPLC method for stability evaluation of nystatin
title_fullStr Development and validation of an HPLC method for stability evaluation of nystatin
title_full_unstemmed Development and validation of an HPLC method for stability evaluation of nystatin
title_short Development and validation of an HPLC method for stability evaluation of nystatin
title_sort development and validation of an hplc method for stability evaluation of nystatin
topic Nistatina
Degradação forçada
Cromatografia líquida de alta eficiência
Nystatin
Forced degradation
High performance liquid chromatography
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000200018
work_keys_str_mv AT anapaolapratacione developmentandvalidationofanhplcmethodforstabilityevaluationofnystatin
AT marciojoseliberale developmentandvalidationofanhplcmethodforstabilityevaluationofnystatin
AT paulomarcosdasilva developmentandvalidationofanhplcmethodforstabilityevaluationofnystatin