Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo

Abstract Background Laryngeal paralysis is a disease process most commonly seen in older, large breed dogs. When both arytenoid cartilages are affected dogs can develop life-threatening respiratory compromise, therefore surgical intervention is recommended. While there are multiple surgical procedur...

Full description

Bibliographic Details
Main Authors: Katelyn E. MacGillivray, Sean D. Bellefeuille, Daniel E. Hoffmann, Lindsay L. St. Germaine
Format: Article
Language:English
Published: BMC 2022-05-01
Series:BMC Veterinary Research
Subjects:
Online Access:https://doi.org/10.1186/s12917-022-03263-y
_version_ 1811250904825856000
author Katelyn E. MacGillivray
Sean D. Bellefeuille
Daniel E. Hoffmann
Lindsay L. St. Germaine
author_facet Katelyn E. MacGillivray
Sean D. Bellefeuille
Daniel E. Hoffmann
Lindsay L. St. Germaine
author_sort Katelyn E. MacGillivray
collection DOAJ
description Abstract Background Laryngeal paralysis is a disease process most commonly seen in older, large breed dogs. When both arytenoid cartilages are affected dogs can develop life-threatening respiratory compromise, therefore surgical intervention is recommended. While there are multiple surgical procedures that have been described to treat laryngeal paralysis, there remains a considerable risk for postoperative complications, most commonly aspiration pneumonia. The objective of this ex vivo experimental study was to evaluate the effects of a novel, 3D printed bilateral arytenoid abductor on laryngeal airway resistance in canine cadaver larynges. Laryngeal airway resistance was calculated for each specimen before (control) and after placement of a 3D printed, bilateral arytenoid abductor. The airway resistance was measured at an airflow of 10 L/min with the epiglottis closed and at airflows ranging from 15 L/min to 60 L/min with the epiglottis open. The effects of the bilateral arytenoid abductor on laryngeal airway resistance were evaluated statistically. Results With the epiglottis open, median laryngeal airway resistance in all larynges with a bilateral arytenoid abductor were significantly decreased at airflows of 15 L/min (0.0cmH2O/L/sec), 30 L/min (0.2cmH2O/L/sec), and 45 L/min (0.2cmH2O/L/sec) compared to the controls 15 L/min (0.4cmH2O/L/sec; P = 0.04), 30 L/min (0.9cmH2O/L/sec; P = 0.04), and 45 L/min (1.2cmH2O/L/sec; P = 0.04). When the epiglottis was closed, there was no significant difference in laryngeal resistance between the control (18.8cmH2O/L/sec) and the abducted larynges (18.1cmH2O/L/sec; P = 0.83). Conclusions Placement of a bilateral arytenoid abductor reduced laryngeal resistance in canine cadaver larynges compared to the controls when the epiglottis was open. With the epiglottis closed, there was no loss of laryngeal resistance while the device abducted the arytenoid cartilages. The results of this ex vivo study is encouraging for consideration of further evaluation of the bilateral arytenoid abductor to determine an appropriate material and tolerance of this device in vivo.
first_indexed 2024-04-12T16:11:44Z
format Article
id doaj.art-4bea5feac108419e83f86df0466d1d9c
institution Directory Open Access Journal
issn 1746-6148
language English
last_indexed 2024-04-12T16:11:44Z
publishDate 2022-05-01
publisher BMC
record_format Article
series BMC Veterinary Research
spelling doaj.art-4bea5feac108419e83f86df0466d1d9c2022-12-22T03:25:52ZengBMCBMC Veterinary Research1746-61482022-05-011811710.1186/s12917-022-03263-yEffects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivoKatelyn E. MacGillivray0Sean D. Bellefeuille1Daniel E. Hoffmann2Lindsay L. St. Germaine3Veterinary Specialists and Emergency ServicesDepartment of Biomedical Engineering, Rochester Institute of TechnologyVeterinary Specialists and Emergency ServicesVeterinary Specialists and Emergency ServicesAbstract Background Laryngeal paralysis is a disease process most commonly seen in older, large breed dogs. When both arytenoid cartilages are affected dogs can develop life-threatening respiratory compromise, therefore surgical intervention is recommended. While there are multiple surgical procedures that have been described to treat laryngeal paralysis, there remains a considerable risk for postoperative complications, most commonly aspiration pneumonia. The objective of this ex vivo experimental study was to evaluate the effects of a novel, 3D printed bilateral arytenoid abductor on laryngeal airway resistance in canine cadaver larynges. Laryngeal airway resistance was calculated for each specimen before (control) and after placement of a 3D printed, bilateral arytenoid abductor. The airway resistance was measured at an airflow of 10 L/min with the epiglottis closed and at airflows ranging from 15 L/min to 60 L/min with the epiglottis open. The effects of the bilateral arytenoid abductor on laryngeal airway resistance were evaluated statistically. Results With the epiglottis open, median laryngeal airway resistance in all larynges with a bilateral arytenoid abductor were significantly decreased at airflows of 15 L/min (0.0cmH2O/L/sec), 30 L/min (0.2cmH2O/L/sec), and 45 L/min (0.2cmH2O/L/sec) compared to the controls 15 L/min (0.4cmH2O/L/sec; P = 0.04), 30 L/min (0.9cmH2O/L/sec; P = 0.04), and 45 L/min (1.2cmH2O/L/sec; P = 0.04). When the epiglottis was closed, there was no significant difference in laryngeal resistance between the control (18.8cmH2O/L/sec) and the abducted larynges (18.1cmH2O/L/sec; P = 0.83). Conclusions Placement of a bilateral arytenoid abductor reduced laryngeal resistance in canine cadaver larynges compared to the controls when the epiglottis was open. With the epiglottis closed, there was no loss of laryngeal resistance while the device abducted the arytenoid cartilages. The results of this ex vivo study is encouraging for consideration of further evaluation of the bilateral arytenoid abductor to determine an appropriate material and tolerance of this device in vivo.https://doi.org/10.1186/s12917-022-03263-yLaryngeal paralysisLaryngeal airway resistanceArytenoid abductor
spellingShingle Katelyn E. MacGillivray
Sean D. Bellefeuille
Daniel E. Hoffmann
Lindsay L. St. Germaine
Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
BMC Veterinary Research
Laryngeal paralysis
Laryngeal airway resistance
Arytenoid abductor
title Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
title_full Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
title_fullStr Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
title_full_unstemmed Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
title_short Effects of a novel, 3D printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
title_sort effects of a novel 3d printed bilateral arytenoid abductor on canine laryngeal airway resistance ex vivo
topic Laryngeal paralysis
Laryngeal airway resistance
Arytenoid abductor
url https://doi.org/10.1186/s12917-022-03263-y
work_keys_str_mv AT katelynemacgillivray effectsofanovel3dprintedbilateralarytenoidabductoroncaninelaryngealairwayresistanceexvivo
AT seandbellefeuille effectsofanovel3dprintedbilateralarytenoidabductoroncaninelaryngealairwayresistanceexvivo
AT danielehoffmann effectsofanovel3dprintedbilateralarytenoidabductoroncaninelaryngealairwayresistanceexvivo
AT lindsaylstgermaine effectsofanovel3dprintedbilateralarytenoidabductoroncaninelaryngealairwayresistanceexvivo