Application of wireless thoracoscopy in thoracic surgery

AbstractTo explore the safety and feasibility of wireless thoracoscope in thoracic surgery. A retrospective analysis was made of all the clinical data of 90 patients with thoracoscope lung resection, from April to August 2021, Shanghai changzheng hospital thoracic minimally invasive center. Compared...

Full description

Bibliographic Details
Main Authors: Ning Xin, Xiaoyu Wu, Junjie Hu, Rongqiang Wei, Zihao Chen, Zhifei Xu, Kenan Huang, Hua Tang
Format: Article
Language:English
Published: Taylor & Francis Group 2023-12-01
Series:Computer Assisted Surgery
Subjects:
Online Access:https://www.tandfonline.com/doi/10.1080/24699322.2022.2162969
_version_ 1797389808820027392
author Ning Xin
Xiaoyu Wu
Junjie Hu
Rongqiang Wei
Zihao Chen
Zhifei Xu
Kenan Huang
Hua Tang
author_facet Ning Xin
Xiaoyu Wu
Junjie Hu
Rongqiang Wei
Zihao Chen
Zhifei Xu
Kenan Huang
Hua Tang
author_sort Ning Xin
collection DOAJ
description AbstractTo explore the safety and feasibility of wireless thoracoscope in thoracic surgery. A retrospective analysis was made of all the clinical data of 90 patients with thoracoscope lung resection, from April to August 2021, Shanghai changzheng hospital thoracic minimally invasive center. Compared the thoracoscope preparation time, picture resolution, picture delay, surgeon comfort level, assistant comfort level between the wireless thoracoscope group and wired thoracoscope group. The thoracoscopic preparation time of the wireless thoracoscope group was significantly shorter than that of the wired group (26.66 ± 6.04 vs 62.14 ± 10.07, p < 0.0001). Comfort level of the surgeon (4.64 ± 0.48 vs 3.77 ± 0.42, p < 0.001) and the comfort level of the assistant (4.85 ± 0.36 vs 3.88 ± 0.32, p < 0.001) of the wireless thoracoscope group were higher than that of the wired thoracoscope group. There were no statistically significant differences in video sharpness (4.64 ± 0.48 vs 4.74 ± 0.44, p = 0.31). Although there was one case picture delay in wireless group, it was caused by low power which could be dealt with by a good charge before surgery. The wireless thoracoscope has the advantages of short preparation time, high comfort for the surgeon and the assistant, no less than the wired thoracoscope in picture resolution and picture delay. Wireless connection is more convenient and portability, which is worthy of further application in clinical practice.
first_indexed 2024-03-08T23:02:25Z
format Article
id doaj.art-4c518853cb8646239bbb02ecec56dccb
institution Directory Open Access Journal
issn 2469-9322
language English
last_indexed 2024-03-08T23:02:25Z
publishDate 2023-12-01
publisher Taylor & Francis Group
record_format Article
series Computer Assisted Surgery
spelling doaj.art-4c518853cb8646239bbb02ecec56dccb2023-12-15T16:06:58ZengTaylor & Francis GroupComputer Assisted Surgery2469-93222023-12-0128110.1080/24699322.2022.2162969Application of wireless thoracoscopy in thoracic surgeryNing Xin0Xiaoyu Wu1Junjie Hu2Rongqiang Wei3Zihao Chen4Zhifei Xu5Kenan Huang6Hua Tang7Department of Thoracic Surgery, Shanghai Changzheng Hospital, Navy Military Medical University, Shanghai, ChinaSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China5th Group of Undergraduates, Naval Medical University, Shanghai, ChinaDepartment of Thoracic Surgery, Shanghai Changzheng Hospital, Navy Military Medical University, Shanghai, ChinaDepartment of Thoracic Surgery, Shanghai Changzheng Hospital, Navy Military Medical University, Shanghai, ChinaDepartment of Thoracic Surgery, Shanghai Changzheng Hospital, Navy Military Medical University, Shanghai, ChinaDepartment of Thoracic Surgery, Shanghai Changzheng Hospital, Navy Military Medical University, Shanghai, ChinaDepartment of Thoracic Surgery, Shanghai Changzheng Hospital, Navy Military Medical University, Shanghai, ChinaAbstractTo explore the safety and feasibility of wireless thoracoscope in thoracic surgery. A retrospective analysis was made of all the clinical data of 90 patients with thoracoscope lung resection, from April to August 2021, Shanghai changzheng hospital thoracic minimally invasive center. Compared the thoracoscope preparation time, picture resolution, picture delay, surgeon comfort level, assistant comfort level between the wireless thoracoscope group and wired thoracoscope group. The thoracoscopic preparation time of the wireless thoracoscope group was significantly shorter than that of the wired group (26.66 ± 6.04 vs 62.14 ± 10.07, p < 0.0001). Comfort level of the surgeon (4.64 ± 0.48 vs 3.77 ± 0.42, p < 0.001) and the comfort level of the assistant (4.85 ± 0.36 vs 3.88 ± 0.32, p < 0.001) of the wireless thoracoscope group were higher than that of the wired thoracoscope group. There were no statistically significant differences in video sharpness (4.64 ± 0.48 vs 4.74 ± 0.44, p = 0.31). Although there was one case picture delay in wireless group, it was caused by low power which could be dealt with by a good charge before surgery. The wireless thoracoscope has the advantages of short preparation time, high comfort for the surgeon and the assistant, no less than the wired thoracoscope in picture resolution and picture delay. Wireless connection is more convenient and portability, which is worthy of further application in clinical practice.https://www.tandfonline.com/doi/10.1080/24699322.2022.2162969Wirelessthoracoscopeminimally invasive
spellingShingle Ning Xin
Xiaoyu Wu
Junjie Hu
Rongqiang Wei
Zihao Chen
Zhifei Xu
Kenan Huang
Hua Tang
Application of wireless thoracoscopy in thoracic surgery
Computer Assisted Surgery
Wireless
thoracoscope
minimally invasive
title Application of wireless thoracoscopy in thoracic surgery
title_full Application of wireless thoracoscopy in thoracic surgery
title_fullStr Application of wireless thoracoscopy in thoracic surgery
title_full_unstemmed Application of wireless thoracoscopy in thoracic surgery
title_short Application of wireless thoracoscopy in thoracic surgery
title_sort application of wireless thoracoscopy in thoracic surgery
topic Wireless
thoracoscope
minimally invasive
url https://www.tandfonline.com/doi/10.1080/24699322.2022.2162969
work_keys_str_mv AT ningxin applicationofwirelessthoracoscopyinthoracicsurgery
AT xiaoyuwu applicationofwirelessthoracoscopyinthoracicsurgery
AT junjiehu applicationofwirelessthoracoscopyinthoracicsurgery
AT rongqiangwei applicationofwirelessthoracoscopyinthoracicsurgery
AT zihaochen applicationofwirelessthoracoscopyinthoracicsurgery
AT zhifeixu applicationofwirelessthoracoscopyinthoracicsurgery
AT kenanhuang applicationofwirelessthoracoscopyinthoracicsurgery
AT huatang applicationofwirelessthoracoscopyinthoracicsurgery