The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.

Syringepump and Infuspump function to provide drugs or fluids that are carried out directly and continuously for a certain period of time through a blood vessel. Often encountered problems of blockage or occlusion in the use of infusion pumps and syringe pumps. Occlusion in the infusion device cause...

Full description

Bibliographic Details
Main Authors: Ach Jiddan Asrori', Endro Yulianto, Triana Rahmawati
Format: Article
Language:English
Published: Jurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes Surabaya 2023-08-01
Series:Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
Subjects:
Online Access:http://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/300
_version_ 1797649852760326144
author Ach Jiddan Asrori'
Endro Yulianto
Triana Rahmawati
author_facet Ach Jiddan Asrori'
Endro Yulianto
Triana Rahmawati
author_sort Ach Jiddan Asrori'
collection DOAJ
description Syringepump and Infuspump function to provide drugs or fluids that are carried out directly and continuously for a certain period of time through a blood vessel. Often encountered problems of blockage or occlusion in the use of infusion pumps and syringe pumps. Occlusion in the infusion device causes the incoming drug fluid to not flow constantly. Occlusion limit set at 20 Psi according to ECRI. To ensure this, proper calibration is required at least once a year. The purpose of this research is to analyze the accuracy of the pressure sensor on the Occlusion measurement on the Infusion Device Analyzer 2 Channel showing TFT. This study has 2 channels so that it can calibrate 2 tools simultaneously. The design of this module uses a Water Pressure Sensor to measure occlusion and a solenoid valve for pressure simulation. When the sensor is depressed, the sensor detects the pressure and is processed by the Arduino. The pressure results are then displayed on a 7-inch TFT LCD in the form of graphs and numbers in real time and stored on the SD card.
first_indexed 2024-03-11T15:52:52Z
format Article
id doaj.art-4c7285c944484f3286fc7d359295d5e6
institution Directory Open Access Journal
issn 2656-8624
language English
last_indexed 2024-03-11T15:52:52Z
publishDate 2023-08-01
publisher Jurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes Surabaya
record_format Article
series Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
spelling doaj.art-4c7285c944484f3286fc7d359295d5e62023-10-25T15:32:43ZengJurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes SurabayaIndonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics2656-86242023-08-015315816410.35882/ijeeemi.v5i3.300300The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.Ach Jiddan Asrori'0Endro Yulianto1Triana Rahmawati2Department of Medical Electronic Engineering Technology, Poltekkes Kemenkes SurabayaDepartment of Electromedical Engineering, Poltekkes Kemenkes Surabaya, Jl. Pucang Jajar Timur No. 10, Surabaya, 60245, IndonesiaDepartment of Electromedical Engineering, Poltekkes Kemenkes Surabaya, Jl. Pucang Jajar Timur No. 10, Surabaya, 60245, IndonesiaSyringepump and Infuspump function to provide drugs or fluids that are carried out directly and continuously for a certain period of time through a blood vessel. Often encountered problems of blockage or occlusion in the use of infusion pumps and syringe pumps. Occlusion in the infusion device causes the incoming drug fluid to not flow constantly. Occlusion limit set at 20 Psi according to ECRI. To ensure this, proper calibration is required at least once a year. The purpose of this research is to analyze the accuracy of the pressure sensor on the Occlusion measurement on the Infusion Device Analyzer 2 Channel showing TFT. This study has 2 channels so that it can calibrate 2 tools simultaneously. The design of this module uses a Water Pressure Sensor to measure occlusion and a solenoid valve for pressure simulation. When the sensor is depressed, the sensor detects the pressure and is processed by the Arduino. The pressure results are then displayed on a 7-inch TFT LCD in the form of graphs and numbers in real time and stored on the SD card.http://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/300calibration, occlusion, syringepump,infuspumpcalibrationocclusionsyringepumpinfuspump
spellingShingle Ach Jiddan Asrori'
Endro Yulianto
Triana Rahmawati
The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
calibration, occlusion, syringepump,infuspump
calibration
occlusion
syringepump
infuspump
title The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.
title_full The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.
title_fullStr The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.
title_full_unstemmed The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.
title_short The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions.
title_sort sensor occlusion sen0257 on the infusion device analyzer 2 channel with tft display ensures high accuracy in detecting occlusions
topic calibration, occlusion, syringepump,infuspump
calibration
occlusion
syringepump
infuspump
url http://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/300
work_keys_str_mv AT achjiddanasrori thesensorocclusionsen0257ontheinfusiondeviceanalyzer2channelwithtftdisplayensureshighaccuracyindetectingocclusions
AT endroyulianto thesensorocclusionsen0257ontheinfusiondeviceanalyzer2channelwithtftdisplayensureshighaccuracyindetectingocclusions
AT trianarahmawati thesensorocclusionsen0257ontheinfusiondeviceanalyzer2channelwithtftdisplayensureshighaccuracyindetectingocclusions
AT achjiddanasrori sensorocclusionsen0257ontheinfusiondeviceanalyzer2channelwithtftdisplayensureshighaccuracyindetectingocclusions
AT endroyulianto sensorocclusionsen0257ontheinfusiondeviceanalyzer2channelwithtftdisplayensureshighaccuracyindetectingocclusions
AT trianarahmawati sensorocclusionsen0257ontheinfusiondeviceanalyzer2channelwithtftdisplayensureshighaccuracyindetectingocclusions