Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study

<p>Abstract</p> <p>Background</p> <p>Prone breast positioning reduces skin reaction and heart and lung dose, but may also reduce radiation dose to axillary lymph nodes (ALNs).</p> <p>Methods</p> <p>Women with early stage breast cancer treated wit...

Full description

Bibliographic Details
Main Authors: Leonard Kara, Solomon David, Hepel Jaroslaw T, Hiatt Jessica R, Wazer David E, DiPetrillo Thomas A
Format: Article
Language:English
Published: BMC 2012-05-01
Series:Radiation Oncology
Subjects:
_version_ 1811245159331921920
author Leonard Kara
Solomon David
Hepel Jaroslaw T
Hiatt Jessica R
Wazer David E
DiPetrillo Thomas A
author_facet Leonard Kara
Solomon David
Hepel Jaroslaw T
Hiatt Jessica R
Wazer David E
DiPetrillo Thomas A
author_sort Leonard Kara
collection DOAJ
description <p>Abstract</p> <p>Background</p> <p>Prone breast positioning reduces skin reaction and heart and lung dose, but may also reduce radiation dose to axillary lymph nodes (ALNs).</p> <p>Methods</p> <p>Women with early stage breast cancer treated with whole breast irradiation (WBI) in the prone position were identified. Patients treated in the supine position were matched for treating physician, laterality, and fractionation. Ipsilateral breast, tumor bed, and Level I, II, and III ALNs were contoured according to the RTOG breast atlas. Clips marking surgically removed sentinel lymph nodes (SLN)s were contoured. Treatment plans developed for each patient were retrospectively analyzed. V90<sub>%</sub> and V95<sub>%</sub> was calculated for each axillary level. When present, dose to axillary surgical clips was calculated.</p> <p>Results</p> <p>Treatment plans for 46 women (23 prone and 23 supine) were reviewed. The mean V90<sub>%</sub> and V95<sub>%</sub> of ALN Level I was significantly lower for patients treated in the prone position (21% and 14%, respectively) than in the supine position (50% and 37%, respectively) (<it>p</it> < 0.0001 and <it>p</it> < 0.0001, respectively). Generally, Level II & III ALNs received little dose in either position. Sentinel node biopsy clips were all contained within axillary Level I. The mean V95<sub>%</sub> of SLN clips was 47% for patients treated in the supine position and 0% for patients treated in the prone position (<it>p</it> < 0.0001). Mean V90<sub>%</sub> to SLN clips was 96% for women treated in the supine position but only 13% for women treated in the prone position.</p> <p>Conclusions</p> <p>Standard tangential breast irradiation in the prone position results in substantially reduced dose to the Level I axilla as compared with treatment in the supine position. For women in whom axillary coverage is indicated such as those with positive sentinel lymph node biopsy who do not undergo completion axillary dissection, treatment in the prone position may be inappropriate.</p>
first_indexed 2024-04-12T14:37:06Z
format Article
id doaj.art-4c83c42ca9e94d6eb0255f75eb5b0b4d
institution Directory Open Access Journal
issn 1748-717X
language English
last_indexed 2024-04-12T14:37:06Z
publishDate 2012-05-01
publisher BMC
record_format Article
series Radiation Oncology
spelling doaj.art-4c83c42ca9e94d6eb0255f75eb5b0b4d2022-12-22T03:29:04ZengBMCRadiation Oncology1748-717X2012-05-01717210.1186/1748-717X-7-72Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric studyLeonard KaraSolomon DavidHepel Jaroslaw THiatt Jessica RWazer David EDiPetrillo Thomas A<p>Abstract</p> <p>Background</p> <p>Prone breast positioning reduces skin reaction and heart and lung dose, but may also reduce radiation dose to axillary lymph nodes (ALNs).</p> <p>Methods</p> <p>Women with early stage breast cancer treated with whole breast irradiation (WBI) in the prone position were identified. Patients treated in the supine position were matched for treating physician, laterality, and fractionation. Ipsilateral breast, tumor bed, and Level I, II, and III ALNs were contoured according to the RTOG breast atlas. Clips marking surgically removed sentinel lymph nodes (SLN)s were contoured. Treatment plans developed for each patient were retrospectively analyzed. V90<sub>%</sub> and V95<sub>%</sub> was calculated for each axillary level. When present, dose to axillary surgical clips was calculated.</p> <p>Results</p> <p>Treatment plans for 46 women (23 prone and 23 supine) were reviewed. The mean V90<sub>%</sub> and V95<sub>%</sub> of ALN Level I was significantly lower for patients treated in the prone position (21% and 14%, respectively) than in the supine position (50% and 37%, respectively) (<it>p</it> < 0.0001 and <it>p</it> < 0.0001, respectively). Generally, Level II & III ALNs received little dose in either position. Sentinel node biopsy clips were all contained within axillary Level I. The mean V95<sub>%</sub> of SLN clips was 47% for patients treated in the supine position and 0% for patients treated in the prone position (<it>p</it> < 0.0001). Mean V90<sub>%</sub> to SLN clips was 96% for women treated in the supine position but only 13% for women treated in the prone position.</p> <p>Conclusions</p> <p>Standard tangential breast irradiation in the prone position results in substantially reduced dose to the Level I axilla as compared with treatment in the supine position. For women in whom axillary coverage is indicated such as those with positive sentinel lymph node biopsy who do not undergo completion axillary dissection, treatment in the prone position may be inappropriate.</p>Breast cancerProneAxillary lymph nodesRadiationACOSOG Z0011
spellingShingle Leonard Kara
Solomon David
Hepel Jaroslaw T
Hiatt Jessica R
Wazer David E
DiPetrillo Thomas A
Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study
Radiation Oncology
Breast cancer
Prone
Axillary lymph nodes
Radiation
ACOSOG Z0011
title Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study
title_full Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study
title_fullStr Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study
title_full_unstemmed Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study
title_short Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study
title_sort axillary lymph node dose with tangential whole breast radiation in the prone versus supine position a dosimetric study
topic Breast cancer
Prone
Axillary lymph nodes
Radiation
ACOSOG Z0011
work_keys_str_mv AT leonardkara axillarylymphnodedosewithtangentialwholebreastradiationintheproneversussupinepositionadosimetricstudy
AT solomondavid axillarylymphnodedosewithtangentialwholebreastradiationintheproneversussupinepositionadosimetricstudy
AT hepeljaroslawt axillarylymphnodedosewithtangentialwholebreastradiationintheproneversussupinepositionadosimetricstudy
AT hiattjessicar axillarylymphnodedosewithtangentialwholebreastradiationintheproneversussupinepositionadosimetricstudy
AT wazerdavide axillarylymphnodedosewithtangentialwholebreastradiationintheproneversussupinepositionadosimetricstudy
AT dipetrillothomasa axillarylymphnodedosewithtangentialwholebreastradiationintheproneversussupinepositionadosimetricstudy