Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial
Abstract BackgroundThe 3-Minute Diagnostic Interview for Confusion Assessment Method–Defined Delirium (3D-CAM) is an instrument specially developed for the assessment of delirium in general wards, with high reported sensitivity and specificity. However, the use of the 3D-CAM b...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
JMIR Publications
2024-01-01
|
Series: | JMIR Aging |
Online Access: | https://aging.jmir.org/2024/1/e51264 |
_version_ | 1797320822569828352 |
---|---|
author | Jiamin Wang Meihua Ji Yuan Han Ying Wu |
author_facet | Jiamin Wang Meihua Ji Yuan Han Ying Wu |
author_sort | Jiamin Wang |
collection | DOAJ |
description |
Abstract
BackgroundThe 3-Minute Diagnostic Interview for Confusion Assessment Method–Defined Delirium (3D-CAM) is an instrument specially developed for the assessment of delirium in general wards, with high reported sensitivity and specificity. However, the use of the 3D-CAM by bedside nurses in routine practice showed relatively poor usability, with multiple human errors during assessment.
ObjectiveThis study aimed to develop a mobile app–based delirium assessment tool based on the 3D-CAM and evaluate its usability among older patients by bedside nurses.
MethodsThe Delirium Assessment Tool With Decision Support Based on the 3D-CAM (3D-DST) was developed to address existing issues of the 3D-CAM and optimize the assessment process. Following a randomized crossover design, questionnaires were used to evaluate the usability of the 3D-DST among older adults by bedside nurses. Meanwhile, the performances of both the 3D-DST and the 3D-CAM paper version, including the assessment completion rate, time required for completing the assessment, and the number of human errors made by nurses during assessment, were recorded, and their differences were compared.
ResultsThe 3D-DST included 3 assessment modules, 9 evaluation interfaces, and 16 results interfaces, with built-in reminders to guide nurses in completing the delirium assessment. In the usability testing, a total of 432 delirium assessments (216 pairs) on 148 older adults were performed by 72 bedside nurses with the 3D-CAM paper version and the 3D-DST. Compared to the 3D-CAM paper version, the mean usability score was significantly higher when using the 3D-DST (4.35 vs 3.40; PPP
ConclusionsThis study demonstrated that the 3D-DST significantly improved the efficiency of delirium assessment and was considered highly acceptable by bedside nurses. |
first_indexed | 2024-03-08T04:48:34Z |
format | Article |
id | doaj.art-4c957c02eef74cb985c4455d3b1c4268 |
institution | Directory Open Access Journal |
issn | 2561-7605 |
language | English |
last_indexed | 2024-03-08T04:48:34Z |
publishDate | 2024-01-01 |
publisher | JMIR Publications |
record_format | Article |
series | JMIR Aging |
spelling | doaj.art-4c957c02eef74cb985c4455d3b1c42682024-02-08T07:14:45ZengJMIR PublicationsJMIR Aging2561-76052024-01-017e51264e5126410.2196/51264Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover TrialJiamin Wanghttp://orcid.org/0000-0003-0228-1849Meihua Jihttp://orcid.org/0000-0002-9421-6077Yuan Hanhttp://orcid.org/0009-0003-1228-9833Ying Wuhttp://orcid.org/0000-0002-8633-5404 Abstract BackgroundThe 3-Minute Diagnostic Interview for Confusion Assessment Method–Defined Delirium (3D-CAM) is an instrument specially developed for the assessment of delirium in general wards, with high reported sensitivity and specificity. However, the use of the 3D-CAM by bedside nurses in routine practice showed relatively poor usability, with multiple human errors during assessment. ObjectiveThis study aimed to develop a mobile app–based delirium assessment tool based on the 3D-CAM and evaluate its usability among older patients by bedside nurses. MethodsThe Delirium Assessment Tool With Decision Support Based on the 3D-CAM (3D-DST) was developed to address existing issues of the 3D-CAM and optimize the assessment process. Following a randomized crossover design, questionnaires were used to evaluate the usability of the 3D-DST among older adults by bedside nurses. Meanwhile, the performances of both the 3D-DST and the 3D-CAM paper version, including the assessment completion rate, time required for completing the assessment, and the number of human errors made by nurses during assessment, were recorded, and their differences were compared. ResultsThe 3D-DST included 3 assessment modules, 9 evaluation interfaces, and 16 results interfaces, with built-in reminders to guide nurses in completing the delirium assessment. In the usability testing, a total of 432 delirium assessments (216 pairs) on 148 older adults were performed by 72 bedside nurses with the 3D-CAM paper version and the 3D-DST. Compared to the 3D-CAM paper version, the mean usability score was significantly higher when using the 3D-DST (4.35 vs 3.40; PPP ConclusionsThis study demonstrated that the 3D-DST significantly improved the efficiency of delirium assessment and was considered highly acceptable by bedside nurses.https://aging.jmir.org/2024/1/e51264 |
spellingShingle | Jiamin Wang Meihua Ji Yuan Han Ying Wu Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial JMIR Aging |
title | Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial |
title_full | Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial |
title_fullStr | Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial |
title_full_unstemmed | Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial |
title_short | Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial |
title_sort | development and usability testing of a mobile app based clinical decision support system for delirium randomized crossover trial |
url | https://aging.jmir.org/2024/1/e51264 |
work_keys_str_mv | AT jiaminwang developmentandusabilitytestingofamobileappbasedclinicaldecisionsupportsystemfordeliriumrandomizedcrossovertrial AT meihuaji developmentandusabilitytestingofamobileappbasedclinicaldecisionsupportsystemfordeliriumrandomizedcrossovertrial AT yuanhan developmentandusabilitytestingofamobileappbasedclinicaldecisionsupportsystemfordeliriumrandomizedcrossovertrial AT yingwu developmentandusabilitytestingofamobileappbasedclinicaldecisionsupportsystemfordeliriumrandomizedcrossovertrial |