Validation of the portable Air-Smart Spirometer.

The Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet.In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hos...

Full description

Bibliographic Details
Main Authors: Cristina Ramos Hernández, Marta Núñez Fernández, Abel Pallares Sanmartín, Cecilia Mouronte Roibas, Luz Cerdeira Domínguez, Maria Isabel Botana Rial, Nagore Blanco Cid, Alberto Fernández Villar
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5825056?pdf=render
_version_ 1818217947927150592
author Cristina Ramos Hernández
Marta Núñez Fernández
Abel Pallares Sanmartín
Cecilia Mouronte Roibas
Luz Cerdeira Domínguez
Maria Isabel Botana Rial
Nagore Blanco Cid
Alberto Fernández Villar
author_facet Cristina Ramos Hernández
Marta Núñez Fernández
Abel Pallares Sanmartín
Cecilia Mouronte Roibas
Luz Cerdeira Domínguez
Maria Isabel Botana Rial
Nagore Blanco Cid
Alberto Fernández Villar
author_sort Cristina Ramos Hernández
collection DOAJ
description The Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet.In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hospital centers, we compare FEV1, FVC, FEV1/FVC ratio measured with the Air Smart-Spirometer device and a conventional spirometer, and analyze the ability of this new portable device to detect obstructions. Patients were included for 2 consecutive months. We calculate sensitivity, specificity, positive and negative predictive value (PPV and NPV) and likelihood ratio (LR +, LR-) as well as the Kappa Index to evaluate the concordance between the two devices for the detection of obstruction. The agreement and relation between the values of FEV1 and FVC in absolute value and the FEV1/FVC ratio measured by both devices were analyzed by calculating the intraclass correlation coefficient (ICC) and the Pearson correlation coefficient (r) respectively.200 patients (100 from each center) were included with a mean age of 57 (± 14) years, 110 were men (55%). Obstruction was detected by conventional spirometry in 73 patients (40.1%). Using a FEV1/FVC ratio smaller than 0.7 to detect obstruction with the Air Smart-Spirometer, the kappa index was 0.88, sensitivity (90.4%), specificity (97.2%), PPV (95.7%), NPV (93.7%), positive likelihood ratio (32.29), and negative likelihood ratio (0.10). The ICC and r between FEV1, FVC, and FEV1 / FVC ratio measured by the Air Smart Spirometer and the conventional spirometer were all higher than 0.94.The Air-Smart Spirometer is a simple and very precise instrument for detecting obstructive airway diseases. It is easy to use, which could make it especially useful non-specialized care and in other areas.
first_indexed 2024-12-12T07:15:58Z
format Article
id doaj.art-4cb5d27c87214b5c869e76f12227c96e
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-12T07:15:58Z
publishDate 2018-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-4cb5d27c87214b5c869e76f12227c96e2022-12-22T00:33:31ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-01132e019278910.1371/journal.pone.0192789Validation of the portable Air-Smart Spirometer.Cristina Ramos HernándezMarta Núñez FernándezAbel Pallares SanmartínCecilia Mouronte RoibasLuz Cerdeira DomínguezMaria Isabel Botana RialNagore Blanco CidAlberto Fernández VillarThe Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet.In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hospital centers, we compare FEV1, FVC, FEV1/FVC ratio measured with the Air Smart-Spirometer device and a conventional spirometer, and analyze the ability of this new portable device to detect obstructions. Patients were included for 2 consecutive months. We calculate sensitivity, specificity, positive and negative predictive value (PPV and NPV) and likelihood ratio (LR +, LR-) as well as the Kappa Index to evaluate the concordance between the two devices for the detection of obstruction. The agreement and relation between the values of FEV1 and FVC in absolute value and the FEV1/FVC ratio measured by both devices were analyzed by calculating the intraclass correlation coefficient (ICC) and the Pearson correlation coefficient (r) respectively.200 patients (100 from each center) were included with a mean age of 57 (± 14) years, 110 were men (55%). Obstruction was detected by conventional spirometry in 73 patients (40.1%). Using a FEV1/FVC ratio smaller than 0.7 to detect obstruction with the Air Smart-Spirometer, the kappa index was 0.88, sensitivity (90.4%), specificity (97.2%), PPV (95.7%), NPV (93.7%), positive likelihood ratio (32.29), and negative likelihood ratio (0.10). The ICC and r between FEV1, FVC, and FEV1 / FVC ratio measured by the Air Smart Spirometer and the conventional spirometer were all higher than 0.94.The Air-Smart Spirometer is a simple and very precise instrument for detecting obstructive airway diseases. It is easy to use, which could make it especially useful non-specialized care and in other areas.http://europepmc.org/articles/PMC5825056?pdf=render
spellingShingle Cristina Ramos Hernández
Marta Núñez Fernández
Abel Pallares Sanmartín
Cecilia Mouronte Roibas
Luz Cerdeira Domínguez
Maria Isabel Botana Rial
Nagore Blanco Cid
Alberto Fernández Villar
Validation of the portable Air-Smart Spirometer.
PLoS ONE
title Validation of the portable Air-Smart Spirometer.
title_full Validation of the portable Air-Smart Spirometer.
title_fullStr Validation of the portable Air-Smart Spirometer.
title_full_unstemmed Validation of the portable Air-Smart Spirometer.
title_short Validation of the portable Air-Smart Spirometer.
title_sort validation of the portable air smart spirometer
url http://europepmc.org/articles/PMC5825056?pdf=render
work_keys_str_mv AT cristinaramoshernandez validationoftheportableairsmartspirometer
AT martanunezfernandez validationoftheportableairsmartspirometer
AT abelpallaressanmartin validationoftheportableairsmartspirometer
AT ceciliamouronteroibas validationoftheportableairsmartspirometer
AT luzcerdeiradominguez validationoftheportableairsmartspirometer
AT mariaisabelbotanarial validationoftheportableairsmartspirometer
AT nagoreblancocid validationoftheportableairsmartspirometer
AT albertofernandezvillar validationoftheportableairsmartspirometer