Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room

Reducing energy consumption in buildings has received intensified research impetus since the introduction of the decarbonization goals set in the Paris agreement. Many domestic and specialized applications require clean rooms (indoor built environments) for safe and clean operation. Energy efficienc...

Full description

Bibliographic Details
Main Authors: Muhammad Rizwan, Shehbaz Ahmad, Syed Nasir Shah, Muzaffar Ali, Mansoor Ul Hassan Shah, Muhammad Zaman, Humbul Suleman, Muddasar Habib, Rasikh Tariq, Jaroslaw Krzywanski
Format: Article
Language:English
Published: MDPI AG 2022-12-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/12/2158
_version_ 1797461075104366592
author Muhammad Rizwan
Shehbaz Ahmad
Syed Nasir Shah
Muzaffar Ali
Mansoor Ul Hassan Shah
Muhammad Zaman
Humbul Suleman
Muddasar Habib
Rasikh Tariq
Jaroslaw Krzywanski
author_facet Muhammad Rizwan
Shehbaz Ahmad
Syed Nasir Shah
Muzaffar Ali
Mansoor Ul Hassan Shah
Muhammad Zaman
Humbul Suleman
Muddasar Habib
Rasikh Tariq
Jaroslaw Krzywanski
author_sort Muhammad Rizwan
collection DOAJ
description Reducing energy consumption in buildings has received intensified research impetus since the introduction of the decarbonization goals set in the Paris agreement. Many domestic and specialized applications require clean rooms (indoor built environments) for safe and clean operation. Energy efficiency in clean room spaces depends on maintaining livable or required conditions such as temperature, humidity, and particle concentration with minimal use of energy and new carbon dioxide (CO<sub>2</sub>) emissions. In the literature, parameters such as temperature, relative humidity, particle concentrations, and CO<sub>2</sub> emissions are not able to be properly controlled in clean room systems. The designed system in the literature involves high energy consumption and high economic costs. All these factors add novelty to this research, which was a significant research gap in previous studies. This clean room is directly linked to environmental parameters such as ambient temperature, relative humidity, etc. The clean room is also related directly to the building and infrastructure in such a way that there are certain regulatory requirements for designing a clean room. For designing and constructing the controlled environment in a clean room, the English (EN) documents, ISO 9000, and various other standards allow for clean rooms for different types of products. In this research, the designed control configurations properly control the system. Additionally, this system is energy efficient, with positive environmental aspects regarding CO<sub>2</sub> emissions. Three control configurations were designed in this research, option A, option B, and option C, and three parameters are controlled in the study. These parameters are room temperature, relative humidity, and CO<sub>2</sub> emissions (outside the room). CO<sub>2</sub> emissions are controlled outside the room (in the environment). In the last research phase, a comparative analysis of these three control configurations was performed to find an energy-efficient system with fewer CO<sub>2</sub> emissions. Control configuration B (option B) provides reliable results regarding an energy-efficient system and fewer CO<sub>2</sub> emissions emitted to the environment. In this study, an optimized configuration for the air conditioning system was developed for a clean room (volume 185.6 m<sup>3</sup>) with a required temperature of 23 °C, relative humidity of 40%, and a particle size of less than 0.3 μm. Three different design configurations were analyzed using TRNSYS simulation software. The minimization of energy use and CO<sub>2</sub> emissions were the objective functions. Energy loads were calculated for each of the configurations by varying the fixed air change per hour and the minimum outdoor air flow rate. The results of a whole year simulation run for control configurations A, B, and show that, on the one hand, the ambient weather conditions of temperature and relative humidity (RH) is varied throughout year and, on the other hand, the clean room temperature was maintain at exactly 23 °C, which is the required set point temperature, for all the three configurations (A, B, and C). Furthermore, the clean room relative humidity was maintained at 36% for configuration A, below the 40% which was the set point for clean room relative humidity, and at 40% for configurations B and C. Configuration B exhibited the minimum energy use (7300 kWh), at a fixed air change per hour value of 20 and a minimum outdoor air flow rate of 150 L/s, with the least amount of CO<sub>2</sub> emissions, offering an overall 25% improvement over configurations A and C.
first_indexed 2024-03-09T17:15:08Z
format Article
id doaj.art-4d532abf1d614482b357b9a789cd6bd4
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T17:15:08Z
publishDate 2022-12-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-4d532abf1d614482b357b9a789cd6bd42023-11-24T13:42:47ZengMDPI AGBuildings2075-53092022-12-011212215810.3390/buildings12122158Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean RoomMuhammad Rizwan0Shehbaz Ahmad1Syed Nasir Shah2Muzaffar Ali3Mansoor Ul Hassan Shah4Muhammad Zaman5Humbul Suleman6Muddasar Habib7Rasikh Tariq8Jaroslaw Krzywanski9Department of Mechanical Engineering, Faculty of Mechanical and Aeronautical Engineering, University of Engineering and Technology Taxila, Rawalpindi 47080, PakistanDepartment of Chemical Engineering, Faculty of Mechanical and Aeronautical Engineering, University of Engineering and Technology, Peshawar, PakistanDepartment of Energy Engineering, University of Engineering and Technology Taxila, Rawalpindi 47080, PakistanDepartment of Mechanical Engineering, Faculty of Mechanical and Aeronautical Engineering, University of Engineering and Technology Taxila, Rawalpindi 47080, PakistanDepartment of Chemical Engineering, Faculty of Mechanical and Aeronautical Engineering, University of Engineering and Technology, Peshawar, PakistanDepartment of Energy Engineering, University of Engineering and Technology Taxila, Rawalpindi 47080, PakistanSchool of Computing, Engineering and Digital Technologies, Teesside University, Middlesbrough TS1 3BX, UKDepartment of Chemical Engineering, Faculty of Mechanical and Aeronautical Engineering, University of Engineering and Technology, Peshawar, PakistanFacultad de Ingeniería, Universidad Autónoma de Yucatán, Av. Industrias No Contaminantes por Anillo Periférico Norte, Apdo. Postal 150, Cordemex, Mérida 97203, MexicoFaculty of Science and Technology, Jan Dlugosz University in Czestochowa, Armii Krajowej 13/15, 42-200 Czestochowa, PolandReducing energy consumption in buildings has received intensified research impetus since the introduction of the decarbonization goals set in the Paris agreement. Many domestic and specialized applications require clean rooms (indoor built environments) for safe and clean operation. Energy efficiency in clean room spaces depends on maintaining livable or required conditions such as temperature, humidity, and particle concentration with minimal use of energy and new carbon dioxide (CO<sub>2</sub>) emissions. In the literature, parameters such as temperature, relative humidity, particle concentrations, and CO<sub>2</sub> emissions are not able to be properly controlled in clean room systems. The designed system in the literature involves high energy consumption and high economic costs. All these factors add novelty to this research, which was a significant research gap in previous studies. This clean room is directly linked to environmental parameters such as ambient temperature, relative humidity, etc. The clean room is also related directly to the building and infrastructure in such a way that there are certain regulatory requirements for designing a clean room. For designing and constructing the controlled environment in a clean room, the English (EN) documents, ISO 9000, and various other standards allow for clean rooms for different types of products. In this research, the designed control configurations properly control the system. Additionally, this system is energy efficient, with positive environmental aspects regarding CO<sub>2</sub> emissions. Three control configurations were designed in this research, option A, option B, and option C, and three parameters are controlled in the study. These parameters are room temperature, relative humidity, and CO<sub>2</sub> emissions (outside the room). CO<sub>2</sub> emissions are controlled outside the room (in the environment). In the last research phase, a comparative analysis of these three control configurations was performed to find an energy-efficient system with fewer CO<sub>2</sub> emissions. Control configuration B (option B) provides reliable results regarding an energy-efficient system and fewer CO<sub>2</sub> emissions emitted to the environment. In this study, an optimized configuration for the air conditioning system was developed for a clean room (volume 185.6 m<sup>3</sup>) with a required temperature of 23 °C, relative humidity of 40%, and a particle size of less than 0.3 μm. Three different design configurations were analyzed using TRNSYS simulation software. The minimization of energy use and CO<sub>2</sub> emissions were the objective functions. Energy loads were calculated for each of the configurations by varying the fixed air change per hour and the minimum outdoor air flow rate. The results of a whole year simulation run for control configurations A, B, and show that, on the one hand, the ambient weather conditions of temperature and relative humidity (RH) is varied throughout year and, on the other hand, the clean room temperature was maintain at exactly 23 °C, which is the required set point temperature, for all the three configurations (A, B, and C). Furthermore, the clean room relative humidity was maintained at 36% for configuration A, below the 40% which was the set point for clean room relative humidity, and at 40% for configurations B and C. Configuration B exhibited the minimum energy use (7300 kWh), at a fixed air change per hour value of 20 and a minimum outdoor air flow rate of 150 L/s, with the least amount of CO<sub>2</sub> emissions, offering an overall 25% improvement over configurations A and C.https://www.mdpi.com/2075-5309/12/12/2158built environmentclean roomTRNSYSsimulationenergy efficiencyenergy load
spellingShingle Muhammad Rizwan
Shehbaz Ahmad
Syed Nasir Shah
Muzaffar Ali
Mansoor Ul Hassan Shah
Muhammad Zaman
Humbul Suleman
Muddasar Habib
Rasikh Tariq
Jaroslaw Krzywanski
Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room
Buildings
built environment
clean room
TRNSYS
simulation
energy efficiency
energy load
title Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room
title_full Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room
title_fullStr Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room
title_full_unstemmed Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room
title_short Optimizing the Air Conditioning Layouts of an Indoor Built Environment: Towards the Energy and Environmental Benefits of a Clean Room
title_sort optimizing the air conditioning layouts of an indoor built environment towards the energy and environmental benefits of a clean room
topic built environment
clean room
TRNSYS
simulation
energy efficiency
energy load
url https://www.mdpi.com/2075-5309/12/12/2158
work_keys_str_mv AT muhammadrizwan optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT shehbazahmad optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT syednasirshah optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT muzaffarali optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT mansoorulhassanshah optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT muhammadzaman optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT humbulsuleman optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT muddasarhabib optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT rasikhtariq optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom
AT jaroslawkrzywanski optimizingtheairconditioninglayoutsofanindoorbuiltenvironmenttowardstheenergyandenvironmentalbenefitsofacleanroom