A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut

A new way to strengthen arched buildings with insufficient bearing capacity of the supports for the perception of the strut is proposed. That method can be implemented in the conditions of architectural and structural solutions of buildings with the presence of zones which prevent the traditional pl...

Full description

Bibliographic Details
Main Authors: Damir M. Khusainov, Aydar F. Salimov, Albina G. Khabibulina
Format: Article
Language:English
Published: Peoples’ Friendship University of Russia (RUDN University) 2022-05-01
Series:Structural Mechanics of Engineering Constructions and Buildings
Subjects:
Online Access:https://journals.rudn.ru/structural-mechanics/article/viewFile/31048/20690
_version_ 1818203582587994112
author Damir M. Khusainov
Aydar F. Salimov
Albina G. Khabibulina
author_facet Damir M. Khusainov
Aydar F. Salimov
Albina G. Khabibulina
author_sort Damir M. Khusainov
collection DOAJ
description A new way to strengthen arched buildings with insufficient bearing capacity of the supports for the perception of the strut is proposed. That method can be implemented in the conditions of architectural and structural solutions of buildings with the presence of zones which prevent the traditional placement of puffs. There are no research results on this problem in the literature. On the example of a frameless arched building with insufficient bearing capacity of the supports for the perception of the strut, the application of the anticipated reinforcement method is considered with the reduction of two options for anchoring the supports of the arched building with puffs installed for the perception of the strut to semi-buried and sunken ground anchor. For the arched building under consideration, theoretical studies were carried out to determine the prestress value in the installed puffs, at which the load-bearing capacity of the arched building is provided for the variant of the asymmetric snow design load. The significance of the obtained results for the construction industry is that for the first time a method of strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut is suggested. The projected method of reinforcement is an effective, novel way to increase the load-bearing capacity of structures and supports of arched buildings and can be used in the conditions of architectural and structural solutions of buildings with the presence of zones that prevent the traditional placement of puffs.
first_indexed 2024-12-12T03:27:38Z
format Article
id doaj.art-4db45fe8abf64233962f08dcc25027f2
institution Directory Open Access Journal
issn 1815-5235
2587-8700
language English
last_indexed 2024-12-12T03:27:38Z
publishDate 2022-05-01
publisher Peoples’ Friendship University of Russia (RUDN University)
record_format Article
series Structural Mechanics of Engineering Constructions and Buildings
spelling doaj.art-4db45fe8abf64233962f08dcc25027f22022-12-22T00:39:59ZengPeoples’ Friendship University of Russia (RUDN University)Structural Mechanics of Engineering Constructions and Buildings1815-52352587-87002022-05-01181354410.22363/1815-5235-2022-18-1-35-4420920A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strutDamir M. Khusainov0https://orcid.org/0000-0002-1671-7546Aydar F. Salimov1https://orcid.org/0000-0003-0295-576XAlbina G. Khabibulina2https://orcid.org/0000-0003-2928-2884Kazan State University of Architecture and EngineeringKazan State University of Architecture and EngineeringKazan State University of Architecture and EngineeringA new way to strengthen arched buildings with insufficient bearing capacity of the supports for the perception of the strut is proposed. That method can be implemented in the conditions of architectural and structural solutions of buildings with the presence of zones which prevent the traditional placement of puffs. There are no research results on this problem in the literature. On the example of a frameless arched building with insufficient bearing capacity of the supports for the perception of the strut, the application of the anticipated reinforcement method is considered with the reduction of two options for anchoring the supports of the arched building with puffs installed for the perception of the strut to semi-buried and sunken ground anchor. For the arched building under consideration, theoretical studies were carried out to determine the prestress value in the installed puffs, at which the load-bearing capacity of the arched building is provided for the variant of the asymmetric snow design load. The significance of the obtained results for the construction industry is that for the first time a method of strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut is suggested. The projected method of reinforcement is an effective, novel way to increase the load-bearing capacity of structures and supports of arched buildings and can be used in the conditions of architectural and structural solutions of buildings with the presence of zones that prevent the traditional placement of puffs.https://journals.rudn.ru/structural-mechanics/article/viewFile/31048/20690arched buildingstrutsupporttighteninganchorframeless arched buildingprestressing
spellingShingle Damir M. Khusainov
Aydar F. Salimov
Albina G. Khabibulina
A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
Structural Mechanics of Engineering Constructions and Buildings
arched building
strut
support
tightening
anchor
frameless arched building
prestressing
title A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
title_full A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
title_fullStr A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
title_full_unstemmed A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
title_short A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
title_sort method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
topic arched building
strut
support
tightening
anchor
frameless arched building
prestressing
url https://journals.rudn.ru/structural-mechanics/article/viewFile/31048/20690
work_keys_str_mv AT damirmkhusainov amethodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut
AT aydarfsalimov amethodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut
AT albinagkhabibulina amethodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut
AT damirmkhusainov methodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut
AT aydarfsalimov methodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut
AT albinagkhabibulina methodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut