A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut
A new way to strengthen arched buildings with insufficient bearing capacity of the supports for the perception of the strut is proposed. That method can be implemented in the conditions of architectural and structural solutions of buildings with the presence of zones which prevent the traditional pl...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Peoples’ Friendship University of Russia (RUDN University)
2022-05-01
|
Series: | Structural Mechanics of Engineering Constructions and Buildings |
Subjects: | |
Online Access: | https://journals.rudn.ru/structural-mechanics/article/viewFile/31048/20690 |
_version_ | 1818203582587994112 |
---|---|
author | Damir M. Khusainov Aydar F. Salimov Albina G. Khabibulina |
author_facet | Damir M. Khusainov Aydar F. Salimov Albina G. Khabibulina |
author_sort | Damir M. Khusainov |
collection | DOAJ |
description | A new way to strengthen arched buildings with insufficient bearing capacity of the supports for the perception of the strut is proposed. That method can be implemented in the conditions of architectural and structural solutions of buildings with the presence of zones which prevent the traditional placement of puffs. There are no research results on this problem in the literature. On the example of a frameless arched building with insufficient bearing capacity of the supports for the perception of the strut, the application of the anticipated reinforcement method is considered with the reduction of two options for anchoring the supports of the arched building with puffs installed for the perception of the strut to semi-buried and sunken ground anchor. For the arched building under consideration, theoretical studies were carried out to determine the prestress value in the installed puffs, at which the load-bearing capacity of the arched building is provided for the variant of the asymmetric snow design load. The significance of the obtained results for the construction industry is that for the first time a method of strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut is suggested. The projected method of reinforcement is an effective, novel way to increase the load-bearing capacity of structures and supports of arched buildings and can be used in the conditions of architectural and structural solutions of buildings with the presence of zones that prevent the traditional placement of puffs. |
first_indexed | 2024-12-12T03:27:38Z |
format | Article |
id | doaj.art-4db45fe8abf64233962f08dcc25027f2 |
institution | Directory Open Access Journal |
issn | 1815-5235 2587-8700 |
language | English |
last_indexed | 2024-12-12T03:27:38Z |
publishDate | 2022-05-01 |
publisher | Peoples’ Friendship University of Russia (RUDN University) |
record_format | Article |
series | Structural Mechanics of Engineering Constructions and Buildings |
spelling | doaj.art-4db45fe8abf64233962f08dcc25027f22022-12-22T00:39:59ZengPeoples’ Friendship University of Russia (RUDN University)Structural Mechanics of Engineering Constructions and Buildings1815-52352587-87002022-05-01181354410.22363/1815-5235-2022-18-1-35-4420920A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strutDamir M. Khusainov0https://orcid.org/0000-0002-1671-7546Aydar F. Salimov1https://orcid.org/0000-0003-0295-576XAlbina G. Khabibulina2https://orcid.org/0000-0003-2928-2884Kazan State University of Architecture and EngineeringKazan State University of Architecture and EngineeringKazan State University of Architecture and EngineeringA new way to strengthen arched buildings with insufficient bearing capacity of the supports for the perception of the strut is proposed. That method can be implemented in the conditions of architectural and structural solutions of buildings with the presence of zones which prevent the traditional placement of puffs. There are no research results on this problem in the literature. On the example of a frameless arched building with insufficient bearing capacity of the supports for the perception of the strut, the application of the anticipated reinforcement method is considered with the reduction of two options for anchoring the supports of the arched building with puffs installed for the perception of the strut to semi-buried and sunken ground anchor. For the arched building under consideration, theoretical studies were carried out to determine the prestress value in the installed puffs, at which the load-bearing capacity of the arched building is provided for the variant of the asymmetric snow design load. The significance of the obtained results for the construction industry is that for the first time a method of strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut is suggested. The projected method of reinforcement is an effective, novel way to increase the load-bearing capacity of structures and supports of arched buildings and can be used in the conditions of architectural and structural solutions of buildings with the presence of zones that prevent the traditional placement of puffs.https://journals.rudn.ru/structural-mechanics/article/viewFile/31048/20690arched buildingstrutsupporttighteninganchorframeless arched buildingprestressing |
spellingShingle | Damir M. Khusainov Aydar F. Salimov Albina G. Khabibulina A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut Structural Mechanics of Engineering Constructions and Buildings arched building strut support tightening anchor frameless arched building prestressing |
title | A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut |
title_full | A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut |
title_fullStr | A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut |
title_full_unstemmed | A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut |
title_short | A method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut |
title_sort | method for strengthening arched buildings with insufficient bearing capacity of supports for the perception of the strut |
topic | arched building strut support tightening anchor frameless arched building prestressing |
url | https://journals.rudn.ru/structural-mechanics/article/viewFile/31048/20690 |
work_keys_str_mv | AT damirmkhusainov amethodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut AT aydarfsalimov amethodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut AT albinagkhabibulina amethodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut AT damirmkhusainov methodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut AT aydarfsalimov methodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut AT albinagkhabibulina methodforstrengtheningarchedbuildingswithinsufficientbearingcapacityofsupportsfortheperceptionofthestrut |