3D biometrics for hindfoot alignment using Weight Bearing CT
Category: Hindfoot Introduction/Purpose: Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the cl...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2018-09-01
|
Series: | Foot & Ankle Orthopaedics |
Online Access: | https://doi.org/10.1177/2473011418S00323 |
_version_ | 1819176077517389824 |
---|---|
author | Francois Lintz MD, FEBOT Shu Zhang MD Alessio Bernasconi MD Jianzhong Zhang MD, PhD |
author_facet | Francois Lintz MD, FEBOT Shu Zhang MD Alessio Bernasconi MD Jianzhong Zhang MD, PhD |
author_sort | Francois Lintz MD, FEBOT |
collection | DOAJ |
description | Category: Hindfoot Introduction/Purpose: Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the clinical relevance and reproducibility of the FAO value for hindfoot alignment and compare it with previous findings. Methods: A prospective study was conducted, with ethics committee approval. Patients were included, clinically examined and divided into 3 groups: normal alignment (Group 1), valgus (Group 2), varus (Group 3). A continuous series of 140 feet (71 patients) were referred from September to December 2017 (65 normal, 41 valgus, and 34 varus). All patients had a bilateral weight bearing CT, and the FAO values were recorded. The long axial view angle(HAct)was measured on Digitally Reconstructed Radiographs (DRR) as comparison. All values were measured and compared by two different investigators. The reproducibility of FAO and HAct were calculated using intraclass correlation coefficients(ICCs) and regression analysis was conducted to study the correlation between the two methods. Results: In Group 1, the mean value for FAO/HAct was 1.69%±2.58%/4.13±2.67, in Group 2, the FAO/HAct was 7.46%±3.18%/9.00±3.43; in Group 3 the values were -6.11%±4.55%/-7.49±6.06. The intra- and interobserver reliability were 0.991/0.992 and 0.976/0.976. There was a good linear correlation between HAct and FAO (R2=0.778, and the regression slope was 1.083. Conclusion: The use of weightbearing CT can help characterize hindfoot alignment objectively using WBCT. The present study is the first prospective comparative assessment of this technology and shows that FAO has good repeatability, and it correlates well with clinical examination,, X ray findings and previous literature. The FAO is a clinically relevant and reproducible method for measuring hindfoot alignment. |
first_indexed | 2024-12-22T21:05:02Z |
format | Article |
id | doaj.art-4dfc7dd9ef524ddc867fa48db1244211 |
institution | Directory Open Access Journal |
issn | 2473-0114 |
language | English |
last_indexed | 2024-12-22T21:05:02Z |
publishDate | 2018-09-01 |
publisher | SAGE Publishing |
record_format | Article |
series | Foot & Ankle Orthopaedics |
spelling | doaj.art-4dfc7dd9ef524ddc867fa48db12442112022-12-21T18:12:41ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142018-09-01310.1177/2473011418S003233D biometrics for hindfoot alignment using Weight Bearing CTFrancois Lintz MD, FEBOTShu Zhang MDAlessio Bernasconi MDJianzhong Zhang MD, PhDCategory: Hindfoot Introduction/Purpose: Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the clinical relevance and reproducibility of the FAO value for hindfoot alignment and compare it with previous findings. Methods: A prospective study was conducted, with ethics committee approval. Patients were included, clinically examined and divided into 3 groups: normal alignment (Group 1), valgus (Group 2), varus (Group 3). A continuous series of 140 feet (71 patients) were referred from September to December 2017 (65 normal, 41 valgus, and 34 varus). All patients had a bilateral weight bearing CT, and the FAO values were recorded. The long axial view angle(HAct)was measured on Digitally Reconstructed Radiographs (DRR) as comparison. All values were measured and compared by two different investigators. The reproducibility of FAO and HAct were calculated using intraclass correlation coefficients(ICCs) and regression analysis was conducted to study the correlation between the two methods. Results: In Group 1, the mean value for FAO/HAct was 1.69%±2.58%/4.13±2.67, in Group 2, the FAO/HAct was 7.46%±3.18%/9.00±3.43; in Group 3 the values were -6.11%±4.55%/-7.49±6.06. The intra- and interobserver reliability were 0.991/0.992 and 0.976/0.976. There was a good linear correlation between HAct and FAO (R2=0.778, and the regression slope was 1.083. Conclusion: The use of weightbearing CT can help characterize hindfoot alignment objectively using WBCT. The present study is the first prospective comparative assessment of this technology and shows that FAO has good repeatability, and it correlates well with clinical examination,, X ray findings and previous literature. The FAO is a clinically relevant and reproducible method for measuring hindfoot alignment.https://doi.org/10.1177/2473011418S00323 |
spellingShingle | Francois Lintz MD, FEBOT Shu Zhang MD Alessio Bernasconi MD Jianzhong Zhang MD, PhD 3D biometrics for hindfoot alignment using Weight Bearing CT Foot & Ankle Orthopaedics |
title | 3D biometrics for hindfoot alignment using Weight Bearing CT |
title_full | 3D biometrics for hindfoot alignment using Weight Bearing CT |
title_fullStr | 3D biometrics for hindfoot alignment using Weight Bearing CT |
title_full_unstemmed | 3D biometrics for hindfoot alignment using Weight Bearing CT |
title_short | 3D biometrics for hindfoot alignment using Weight Bearing CT |
title_sort | 3d biometrics for hindfoot alignment using weight bearing ct |
url | https://doi.org/10.1177/2473011418S00323 |
work_keys_str_mv | AT francoislintzmdfebot 3dbiometricsforhindfootalignmentusingweightbearingct AT shuzhangmd 3dbiometricsforhindfootalignmentusingweightbearingct AT alessiobernasconimd 3dbiometricsforhindfootalignmentusingweightbearingct AT jianzhongzhangmdphd 3dbiometricsforhindfootalignmentusingweightbearingct |