3D biometrics for hindfoot alignment using Weight Bearing CT

Category: Hindfoot Introduction/Purpose: Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the cl...

Full description

Bibliographic Details
Main Authors: Francois Lintz MD, FEBOT, Shu Zhang MD, Alessio Bernasconi MD, Jianzhong Zhang MD, PhD
Format: Article
Language:English
Published: SAGE Publishing 2018-09-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011418S00323
_version_ 1819176077517389824
author Francois Lintz MD, FEBOT
Shu Zhang MD
Alessio Bernasconi MD
Jianzhong Zhang MD, PhD
author_facet Francois Lintz MD, FEBOT
Shu Zhang MD
Alessio Bernasconi MD
Jianzhong Zhang MD, PhD
author_sort Francois Lintz MD, FEBOT
collection DOAJ
description Category: Hindfoot Introduction/Purpose: Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the clinical relevance and reproducibility of the FAO value for hindfoot alignment and compare it with previous findings. Methods: A prospective study was conducted, with ethics committee approval. Patients were included, clinically examined and divided into 3 groups: normal alignment (Group 1), valgus (Group 2), varus (Group 3). A continuous series of 140 feet (71 patients) were referred from September to December 2017 (65 normal, 41 valgus, and 34 varus). All patients had a bilateral weight bearing CT, and the FAO values were recorded. The long axial view angle(HAct)was measured on Digitally Reconstructed Radiographs (DRR) as comparison. All values were measured and compared by two different investigators. The reproducibility of FAO and HAct were calculated using intraclass correlation coefficients(ICCs) and regression analysis was conducted to study the correlation between the two methods. Results: In Group 1, the mean value for FAO/HAct was 1.69%±2.58%/4.13±2.67, in Group 2, the FAO/HAct was 7.46%±3.18%/9.00±3.43; in Group 3 the values were -6.11%±4.55%/-7.49±6.06. The intra- and interobserver reliability were 0.991/0.992 and 0.976/0.976. There was a good linear correlation between HAct and FAO (R2=0.778, and the regression slope was 1.083. Conclusion: The use of weightbearing CT can help characterize hindfoot alignment objectively using WBCT. The present study is the first prospective comparative assessment of this technology and shows that FAO has good repeatability, and it correlates well with clinical examination,, X ray findings and previous literature. The FAO is a clinically relevant and reproducible method for measuring hindfoot alignment.
first_indexed 2024-12-22T21:05:02Z
format Article
id doaj.art-4dfc7dd9ef524ddc867fa48db1244211
institution Directory Open Access Journal
issn 2473-0114
language English
last_indexed 2024-12-22T21:05:02Z
publishDate 2018-09-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj.art-4dfc7dd9ef524ddc867fa48db12442112022-12-21T18:12:41ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142018-09-01310.1177/2473011418S003233D biometrics for hindfoot alignment using Weight Bearing CTFrancois Lintz MD, FEBOTShu Zhang MDAlessio Bernasconi MDJianzhong Zhang MD, PhDCategory: Hindfoot Introduction/Purpose: Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the clinical relevance and reproducibility of the FAO value for hindfoot alignment and compare it with previous findings. Methods: A prospective study was conducted, with ethics committee approval. Patients were included, clinically examined and divided into 3 groups: normal alignment (Group 1), valgus (Group 2), varus (Group 3). A continuous series of 140 feet (71 patients) were referred from September to December 2017 (65 normal, 41 valgus, and 34 varus). All patients had a bilateral weight bearing CT, and the FAO values were recorded. The long axial view angle(HAct)was measured on Digitally Reconstructed Radiographs (DRR) as comparison. All values were measured and compared by two different investigators. The reproducibility of FAO and HAct were calculated using intraclass correlation coefficients(ICCs) and regression analysis was conducted to study the correlation between the two methods. Results: In Group 1, the mean value for FAO/HAct was 1.69%±2.58%/4.13±2.67, in Group 2, the FAO/HAct was 7.46%±3.18%/9.00±3.43; in Group 3 the values were -6.11%±4.55%/-7.49±6.06. The intra- and interobserver reliability were 0.991/0.992 and 0.976/0.976. There was a good linear correlation between HAct and FAO (R2=0.778, and the regression slope was 1.083. Conclusion: The use of weightbearing CT can help characterize hindfoot alignment objectively using WBCT. The present study is the first prospective comparative assessment of this technology and shows that FAO has good repeatability, and it correlates well with clinical examination,, X ray findings and previous literature. The FAO is a clinically relevant and reproducible method for measuring hindfoot alignment.https://doi.org/10.1177/2473011418S00323
spellingShingle Francois Lintz MD, FEBOT
Shu Zhang MD
Alessio Bernasconi MD
Jianzhong Zhang MD, PhD
3D biometrics for hindfoot alignment using Weight Bearing CT
Foot & Ankle Orthopaedics
title 3D biometrics for hindfoot alignment using Weight Bearing CT
title_full 3D biometrics for hindfoot alignment using Weight Bearing CT
title_fullStr 3D biometrics for hindfoot alignment using Weight Bearing CT
title_full_unstemmed 3D biometrics for hindfoot alignment using Weight Bearing CT
title_short 3D biometrics for hindfoot alignment using Weight Bearing CT
title_sort 3d biometrics for hindfoot alignment using weight bearing ct
url https://doi.org/10.1177/2473011418S00323
work_keys_str_mv AT francoislintzmdfebot 3dbiometricsforhindfootalignmentusingweightbearingct
AT shuzhangmd 3dbiometricsforhindfootalignmentusingweightbearingct
AT alessiobernasconimd 3dbiometricsforhindfootalignmentusingweightbearingct
AT jianzhongzhangmdphd 3dbiometricsforhindfootalignmentusingweightbearingct