Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector

Introduction: Elekta Versa HD linear accelerator is equipped with a universal wedge filter which is a single large physical wedge driven by motors; in other words, motorized wedge. It provides a nominal wedge isodose angle of 60° for the field size of 30×40 sq. cm. Motorized wedge isodose distributi...

Full description

Bibliographic Details
Main Authors: Jaimin Gamit, shreekripa rao, Jyothi N, Sarath Nair, Shambhavi Charan, Rechal Dsouza, Krishan Sharan, Srinidhi Chandraguthi
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2020-11-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:http://ijmp.mums.ac.ir/article_14115_e2691752b4ec2f58c6a1ebdc182d2163.pdf
_version_ 1818267023729229824
author Jaimin Gamit
shreekripa rao
Jyothi N
Sarath Nair
Shambhavi Charan
Rechal Dsouza
Krishan Sharan
Srinidhi Chandraguthi
author_facet Jaimin Gamit
shreekripa rao
Jyothi N
Sarath Nair
Shambhavi Charan
Rechal Dsouza
Krishan Sharan
Srinidhi Chandraguthi
author_sort Jaimin Gamit
collection DOAJ
description Introduction: Elekta Versa HD linear accelerator is equipped with a universal wedge filter which is a single large physical wedge driven by motors; in other words, motorized wedge. It provides a nominal wedge isodose angle of 60° for the field size of 30×40 sq. cm. Motorized wedge isodose distribution generated is a combination of open and wedged beam segments. With this background in mind, the present study aimed to validate the planned wedge effective isodose angle. Material and Methods: The current study validated the planned wedge effective isodose angle for  15°, 30°, 45°, and 60°  with 6MV and 15MV for 10x10 sq. cm and 20x20 sq. cm field size. To this end, an analytical formula was applied against a 2D array detector using PTW MultiCheck software. Results: As illustrated by the obtained results, the calculated, measured, and planned wedge effective isodose angle in this work represented a maximum deviation from its pre-set angle (a nominal wedge angle) of  9° for a 6MV photon energy and 5° for 15MV for field sizes of 10×10 sq. cm and 20×20 sq. cm. Conclusion: In the present study, we validated the planned wedge effective isodose angle for field sizes of 10x10sq. cm and 20x20sq. cm for 6MV and 15MV photon energies using an analytical method and 2D array detector with a reasonable agreement.
first_indexed 2024-12-12T20:16:00Z
format Article
id doaj.art-4e1c14cce5f2412abf0b9b701ba09075
institution Directory Open Access Journal
issn 2345-3672
2345-3672
language English
last_indexed 2024-12-12T20:16:00Z
publishDate 2020-11-01
publisher Mashhad University of Medical Sciences
record_format Article
series Iranian Journal of Medical Physics
spelling doaj.art-4e1c14cce5f2412abf0b9b701ba090752022-12-22T00:13:23ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722020-11-0117638038510.22038/ijmp.2019.38832.150814115Validation of Motorized Wedge Effective Isodose Angle with a 2D Array DetectorJaimin Gamit0shreekripa rao1Jyothi N2Sarath Nair3Shambhavi Charan4Rechal Dsouza5Krishan Sharan6Srinidhi Chandraguthi7Radiotherapy and Oncology M.Sc Medical Radiation Physics Student School of Allied Health Sciences Manipal Academy of Higher Education Manipal IndiaRadiotherapy and Oncology Assistant Professor in Medical Physics School of Allied Health Sciences Kasturba Medical College Manipal Academy of Higher Education Manipal 576104Radiotherapy and Oncology Senior Grade Lecturer Medical Physics Kasturba Medical College Manipal Academy of Higher Education Manipal IndiaRadiotherapy and Oncology Lecturer Medical Physics Kasturba Medical College Manipal Academy of Higher Education Manipal IndiaRadiotherapy and Oncology Assistant Professor in Medical Physics School of Allied Health Sciences Kasturba Medical College Manipal Academy of Higher Education Manipal IndiaRadiotherapy and Oncology Assistant Professor in Medical Physics School of Allied Health Sciences Kasturba Medical College Manipal Academy of Higher Education Manipal IndiaRadiotherapy and Oncology Professor and Head Kasturba Medical College Manipal Academy of Higher Education Manipal IndiaRadiotherapy and Oncology Senior Grade Lecturer Medical Physics Kasturba Medical College Manipal Academy of Higher Education Manipal IndiaIntroduction: Elekta Versa HD linear accelerator is equipped with a universal wedge filter which is a single large physical wedge driven by motors; in other words, motorized wedge. It provides a nominal wedge isodose angle of 60° for the field size of 30×40 sq. cm. Motorized wedge isodose distribution generated is a combination of open and wedged beam segments. With this background in mind, the present study aimed to validate the planned wedge effective isodose angle. Material and Methods: The current study validated the planned wedge effective isodose angle for  15°, 30°, 45°, and 60°  with 6MV and 15MV for 10x10 sq. cm and 20x20 sq. cm field size. To this end, an analytical formula was applied against a 2D array detector using PTW MultiCheck software. Results: As illustrated by the obtained results, the calculated, measured, and planned wedge effective isodose angle in this work represented a maximum deviation from its pre-set angle (a nominal wedge angle) of  9° for a 6MV photon energy and 5° for 15MV for field sizes of 10×10 sq. cm and 20×20 sq. cm. Conclusion: In the present study, we validated the planned wedge effective isodose angle for field sizes of 10x10sq. cm and 20x20sq. cm for 6MV and 15MV photon energies using an analytical method and 2D array detector with a reasonable agreement.http://ijmp.mums.ac.ir/article_14115_e2691752b4ec2f58c6a1ebdc182d2163.pdfxrays radiometry particle accelerators quality control radiotherapy planning computerassisted
spellingShingle Jaimin Gamit
shreekripa rao
Jyothi N
Sarath Nair
Shambhavi Charan
Rechal Dsouza
Krishan Sharan
Srinidhi Chandraguthi
Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
Iranian Journal of Medical Physics
x
rays radiometry particle accelerators quality control radiotherapy planning computer
assisted
title Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
title_full Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
title_fullStr Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
title_full_unstemmed Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
title_short Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
title_sort validation of motorized wedge effective isodose angle with a 2d array detector
topic x
rays radiometry particle accelerators quality control radiotherapy planning computer
assisted
url http://ijmp.mums.ac.ir/article_14115_e2691752b4ec2f58c6a1ebdc182d2163.pdf
work_keys_str_mv AT jaimingamit validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT shreekriparao validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT jyothin validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT sarathnair validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT shambhavicharan validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT rechaldsouza validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT krishansharan validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector
AT srinidhichandraguthi validationofmotorizedwedgeeffectiveisodoseanglewitha2darraydetector