Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method

LaBr3:(Ce) exhibits the best energy resolution among scintillation γ-ray detectors. The excellent energy resolution of this detector has made it suitable for many radiation detection applications such as environmental monitoring, medical imaging, nuclear security, nuclear physics experiments, etc. H...

Full description

Bibliographic Details
Main Author: Thamer Alharbi
Format: Article
Language:English
Published: Elsevier 2022-06-01
Series:Journal of King Saud University: Science
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1018364722001069
_version_ 1818551934056923136
author Thamer Alharbi
author_facet Thamer Alharbi
author_sort Thamer Alharbi
collection DOAJ
description LaBr3:(Ce) exhibits the best energy resolution among scintillation γ-ray detectors. The excellent energy resolution of this detector has made it suitable for many radiation detection applications such as environmental monitoring, medical imaging, nuclear security, nuclear physics experiments, etc. However, LaBr3:(Ce) crystal endures from internal radioactivity which produces a considerable background in the measurements. The problem of internal radiation is particularly acute with large size detectors, measuring low-intensity γ-rays. A considerable part of the internal radiation comes from the α-decay of 227Ac and its daughters which are present as an impurity in the detector’s crystal. Unfortunately, due to the very similar chemical properties of Actinium and Lanthanum, it is very difficult to remove the 227Ac impurity by using purification processes, and therefore, the α-background is present in all the commercial crystals. A practical approach for the reduction of this problem is to identify the α-events through an electronic analysis of the shape of output pulses of the detector and reject them. In the past, several digital pulse-shape discrimination (PSD) methods have been proposed to suppress the internal α background in LaBr3:(Ce) detectors. These methods exploit the small difference in the shape of scintillation pulses from α- and γ-ray interactions. The PSD methods have demonstrated some degree of success, which are limited to only a partial rejection of the α-background while further reduction of the α background is highly desirable for low-background γ-ray measurements. In this work, a novel digital PSD method that significantly improves the rejection of the internal α background was developed. The PSD method is based on the wavelet transform of the scintillation pulses, leading to an almost complete rejection of the α background. This method is very useful for low-level radiation measurements with LaBr3:(Ce) detectors involving high-energy γ rays.
first_indexed 2024-12-12T09:06:29Z
format Article
id doaj.art-4ede67523f4e431ea4f0905ff1bc8f00
institution Directory Open Access Journal
issn 1018-3647
language English
last_indexed 2024-12-12T09:06:29Z
publishDate 2022-06-01
publisher Elsevier
record_format Article
series Journal of King Saud University: Science
spelling doaj.art-4ede67523f4e431ea4f0905ff1bc8f002022-12-22T00:29:40ZengElsevierJournal of King Saud University: Science1018-36472022-06-01344101925Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination methodThamer Alharbi0Department of Physics, College of Science in Zulfi, Majmaah University, Majmaah 11932, Saudi ArabiaLaBr3:(Ce) exhibits the best energy resolution among scintillation γ-ray detectors. The excellent energy resolution of this detector has made it suitable for many radiation detection applications such as environmental monitoring, medical imaging, nuclear security, nuclear physics experiments, etc. However, LaBr3:(Ce) crystal endures from internal radioactivity which produces a considerable background in the measurements. The problem of internal radiation is particularly acute with large size detectors, measuring low-intensity γ-rays. A considerable part of the internal radiation comes from the α-decay of 227Ac and its daughters which are present as an impurity in the detector’s crystal. Unfortunately, due to the very similar chemical properties of Actinium and Lanthanum, it is very difficult to remove the 227Ac impurity by using purification processes, and therefore, the α-background is present in all the commercial crystals. A practical approach for the reduction of this problem is to identify the α-events through an electronic analysis of the shape of output pulses of the detector and reject them. In the past, several digital pulse-shape discrimination (PSD) methods have been proposed to suppress the internal α background in LaBr3:(Ce) detectors. These methods exploit the small difference in the shape of scintillation pulses from α- and γ-ray interactions. The PSD methods have demonstrated some degree of success, which are limited to only a partial rejection of the α-background while further reduction of the α background is highly desirable for low-background γ-ray measurements. In this work, a novel digital PSD method that significantly improves the rejection of the internal α background was developed. The PSD method is based on the wavelet transform of the scintillation pulses, leading to an almost complete rejection of the α background. This method is very useful for low-level radiation measurements with LaBr3:(Ce) detectors involving high-energy γ rays.http://www.sciencedirect.com/science/article/pii/S1018364722001069LaBr3:(Ce)Pulse-shape discriminationγ-Ray spectroscopyInternal radiation
spellingShingle Thamer Alharbi
Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method
Journal of King Saud University: Science
LaBr3:(Ce)
Pulse-shape discrimination
γ-Ray spectroscopy
Internal radiation
title Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method
title_full Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method
title_fullStr Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method
title_full_unstemmed Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method
title_short Rejection of the internal α background in LaBr3:(Ce) detectors by using a wavelet-based pulse-shape discrimination method
title_sort rejection of the internal α background in labr3 ce detectors by using a wavelet based pulse shape discrimination method
topic LaBr3:(Ce)
Pulse-shape discrimination
γ-Ray spectroscopy
Internal radiation
url http://www.sciencedirect.com/science/article/pii/S1018364722001069
work_keys_str_mv AT thameralharbi rejectionoftheinternalabackgroundinlabr3cedetectorsbyusingawaveletbasedpulseshapediscriminationmethod