Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques

Background:. Lower lip augmentation by filler injection is an aesthetic procedure essential for achieving a feminine look and to enhance attractiveness. Complications as a result of injury to the inferior labial artery can result in undesirable outcomes. Methods:. The translucent technique was use...

Full description

Bibliographic Details
Main Authors: Tanvaa Tansatit, MD, MSc, Thirawass Phumyoo, MSc, Hannah MCCabe, MSc, Benrita Jitaree, PhD
Format: Article
Language:English
Published: Wolters Kluwer 2019-09-01
Series:Plastic and Reconstructive Surgery, Global Open
Online Access:http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000002399
_version_ 1818477245593812992
author Tanvaa Tansatit, MD, MSc
Thirawass Phumyoo, MSc
Hannah MCCabe, MSc
Benrita Jitaree, PhD
author_facet Tanvaa Tansatit, MD, MSc
Thirawass Phumyoo, MSc
Hannah MCCabe, MSc
Benrita Jitaree, PhD
author_sort Tanvaa Tansatit, MD, MSc
collection DOAJ
description Background:. Lower lip augmentation by filler injection is an aesthetic procedure essential for achieving a feminine look and to enhance attractiveness. Complications as a result of injury to the inferior labial artery can result in undesirable outcomes. Methods:. The translucent technique was used to study the origin of the inferior labial artery in 11 cadavers. Ultrasonography of the inferior labial artery was also performed in 20 volunteers, which provided supplemental data to this study, in relation to establishing recommendations for filler injection. Results:. Five different types of inferior labial artery were described. These types were found in various combination patterns. Types 2, 4, and 5 are more vulnerable to arterial injury during filler injection. Ultrasonography revealed a depth of 6 mm and an arterial position at the vermillion border as the dangerous injection plane. Conclusion:. The origins and courses of the inferior labial artery are classified into 5 types. These types are often found in combination with each other in different faces, resulting in large anatomical variation between people. Types of combination influence severity of lower lip necrosis when arterial injury occurs. The physician should be aware of these anatomical variations during aesthetic treatments and reconstructive procedures to avoid the dangers of accidental arterial injury.
first_indexed 2024-12-10T09:35:38Z
format Article
id doaj.art-4eed245b793e4927a7566f6b50ee96ce
institution Directory Open Access Journal
issn 2169-7574
language English
last_indexed 2024-12-10T09:35:38Z
publishDate 2019-09-01
publisher Wolters Kluwer
record_format Article
series Plastic and Reconstructive Surgery, Global Open
spelling doaj.art-4eed245b793e4927a7566f6b50ee96ce2022-12-22T01:54:12ZengWolters KluwerPlastic and Reconstructive Surgery, Global Open2169-75742019-09-0179e239910.1097/GOX.0000000000002399201909000-00004Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection TechniquesTanvaa Tansatit, MD, MSc0Thirawass Phumyoo, MSc1Hannah MCCabe, MSc2Benrita Jitaree, PhD3From the *Department of Anatomy, Faculty of Medicine, and The Chula Soft Cadaver Surgical Training Center, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, ThailandFrom the *Department of Anatomy, Faculty of Medicine, and The Chula Soft Cadaver Surgical Training Center, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand†Anatomy and Human Biology, University of Birmingham, Birmingham, United KingdomFrom the *Department of Anatomy, Faculty of Medicine, and The Chula Soft Cadaver Surgical Training Center, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, ThailandBackground:. Lower lip augmentation by filler injection is an aesthetic procedure essential for achieving a feminine look and to enhance attractiveness. Complications as a result of injury to the inferior labial artery can result in undesirable outcomes. Methods:. The translucent technique was used to study the origin of the inferior labial artery in 11 cadavers. Ultrasonography of the inferior labial artery was also performed in 20 volunteers, which provided supplemental data to this study, in relation to establishing recommendations for filler injection. Results:. Five different types of inferior labial artery were described. These types were found in various combination patterns. Types 2, 4, and 5 are more vulnerable to arterial injury during filler injection. Ultrasonography revealed a depth of 6 mm and an arterial position at the vermillion border as the dangerous injection plane. Conclusion:. The origins and courses of the inferior labial artery are classified into 5 types. These types are often found in combination with each other in different faces, resulting in large anatomical variation between people. Types of combination influence severity of lower lip necrosis when arterial injury occurs. The physician should be aware of these anatomical variations during aesthetic treatments and reconstructive procedures to avoid the dangers of accidental arterial injury.http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000002399
spellingShingle Tanvaa Tansatit, MD, MSc
Thirawass Phumyoo, MSc
Hannah MCCabe, MSc
Benrita Jitaree, PhD
Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques
Plastic and Reconstructive Surgery, Global Open
title Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques
title_full Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques
title_fullStr Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques
title_full_unstemmed Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques
title_short Translucent and Ultrasonographic Studies of the Inferior Labial Artery for Improvement of Filler Injection Techniques
title_sort translucent and ultrasonographic studies of the inferior labial artery for improvement of filler injection techniques
url http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000002399
work_keys_str_mv AT tanvaatansatitmdmsc translucentandultrasonographicstudiesoftheinferiorlabialarteryforimprovementoffillerinjectiontechniques
AT thirawassphumyoomsc translucentandultrasonographicstudiesoftheinferiorlabialarteryforimprovementoffillerinjectiontechniques
AT hannahmccabemsc translucentandultrasonographicstudiesoftheinferiorlabialarteryforimprovementoffillerinjectiontechniques
AT benritajitareephd translucentandultrasonographicstudiesoftheinferiorlabialarteryforimprovementoffillerinjectiontechniques