A Rational Approach to Determining Environmental Noise Indicators
Environmental noise indicator values that are completely accurate and precise can only be obtained through continuous noise monitoring, which is a highly complex and multifaceted task. In case heavy road traffic is the dominant noise source, accurate and precise data on annual noise indicator values...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in Osijek
2022-01-01
|
Series: | Tehnički Vjesnik |
Subjects: | |
Online Access: | https://hrcak.srce.hr/file/395143 |
_version_ | 1797206785706164224 |
---|---|
author | Darko Mihajlov* Momir Praščević Marko Ličanin Miomir Raos Branko Radičević |
author_facet | Darko Mihajlov* Momir Praščević Marko Ličanin Miomir Raos Branko Radičević |
author_sort | Darko Mihajlov* |
collection | DOAJ |
description | Environmental noise indicator values that are completely accurate and precise can only be obtained through continuous noise monitoring, which is a highly complex and multifaceted task. In case heavy road traffic is the dominant noise source, accurate and precise data on annual noise indicator values are also obtainable through semicontinuous monitoring. Such a procedure is a rational approach to the given task, as it requires considerably shorter utilization of resources, whereby the primary issue is how to choose the measurement time interval. To help determine the optimal measurement time interval, this paper uses the results of continuous noise monitoring at a selected measurement location as an attempt to minimize the measurement time interval. The choice of the optimal measuring strategy of the problem defined by multiple criteria has been made using the PROMETHEE method, as the most acceptable method for comparing the different alternatives. |
first_indexed | 2024-04-24T09:12:32Z |
format | Article |
id | doaj.art-4f07631a64f64e6781744d1e041ed662 |
institution | Directory Open Access Journal |
issn | 1330-3651 1848-6339 |
language | English |
last_indexed | 2024-04-24T09:12:32Z |
publishDate | 2022-01-01 |
publisher | Faculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in Osijek |
record_format | Article |
series | Tehnički Vjesnik |
spelling | doaj.art-4f07631a64f64e6781744d1e041ed6622024-04-15T17:34:58ZengFaculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in OsijekTehnički Vjesnik1330-36511848-63392022-01-0129255356010.17559/TV-20210226134508A Rational Approach to Determining Environmental Noise IndicatorsDarko Mihajlov*0Momir Praščević1Marko Ličanin2Miomir Raos3Branko Radičević4University of Niš, Faculty of Occupational Safety, Čarnojevića 10a, 18 000 Niš, SerbiaUniversity of Niš, Faculty of Occupational Safety, Čarnojevića 10a, 18 000 Niš, SerbiaUniversity of Niš, Faculty of Occupational Safety, Čarnojevića 10a, 18 000 Niš, SerbiaUniversity of Niš, Faculty of Occupational Safety, Čarnojevića 10a, 18 000 Niš, SerbiaUniversity of Kragujevac, Faculty of Mechanical and Civil Engineering in Kraljevo, Dositejeva 19, 36 000 Kraljevo, SerbiaEnvironmental noise indicator values that are completely accurate and precise can only be obtained through continuous noise monitoring, which is a highly complex and multifaceted task. In case heavy road traffic is the dominant noise source, accurate and precise data on annual noise indicator values are also obtainable through semicontinuous monitoring. Such a procedure is a rational approach to the given task, as it requires considerably shorter utilization of resources, whereby the primary issue is how to choose the measurement time interval. To help determine the optimal measurement time interval, this paper uses the results of continuous noise monitoring at a selected measurement location as an attempt to minimize the measurement time interval. The choice of the optimal measuring strategy of the problem defined by multiple criteria has been made using the PROMETHEE method, as the most acceptable method for comparing the different alternatives.https://hrcak.srce.hr/file/395143measurement time intervalmulti-criteria optimizationnoise monitoringPROMETHEE methodroad traffic noise |
spellingShingle | Darko Mihajlov* Momir Praščević Marko Ličanin Miomir Raos Branko Radičević A Rational Approach to Determining Environmental Noise Indicators Tehnički Vjesnik measurement time interval multi-criteria optimization noise monitoring PROMETHEE method road traffic noise |
title | A Rational Approach to Determining Environmental Noise Indicators |
title_full | A Rational Approach to Determining Environmental Noise Indicators |
title_fullStr | A Rational Approach to Determining Environmental Noise Indicators |
title_full_unstemmed | A Rational Approach to Determining Environmental Noise Indicators |
title_short | A Rational Approach to Determining Environmental Noise Indicators |
title_sort | rational approach to determining environmental noise indicators |
topic | measurement time interval multi-criteria optimization noise monitoring PROMETHEE method road traffic noise |
url | https://hrcak.srce.hr/file/395143 |
work_keys_str_mv | AT darkomihajlov arationalapproachtodeterminingenvironmentalnoiseindicators AT momirprascevic arationalapproachtodeterminingenvironmentalnoiseindicators AT markolicanin arationalapproachtodeterminingenvironmentalnoiseindicators AT miomirraos arationalapproachtodeterminingenvironmentalnoiseindicators AT brankoradicevic arationalapproachtodeterminingenvironmentalnoiseindicators AT darkomihajlov rationalapproachtodeterminingenvironmentalnoiseindicators AT momirprascevic rationalapproachtodeterminingenvironmentalnoiseindicators AT markolicanin rationalapproachtodeterminingenvironmentalnoiseindicators AT miomirraos rationalapproachtodeterminingenvironmentalnoiseindicators AT brankoradicevic rationalapproachtodeterminingenvironmentalnoiseindicators |