Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis
Aim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according t...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-06-01
|
Series: | Journal of Clinical Medicine |
Subjects: | |
Online Access: | https://www.mdpi.com/2077-0383/10/13/2760 |
_version_ | 1797529013103624192 |
---|---|
author | María León-López Daniel Cabanillas-Balsera Victoria Areal-Quecuty Jenifer Martín-González María C. Jiménez-Sánchez Juan J. Saúco-Márquez Benito Sánchez-Domínguez Juan J. Segura-Egea |
author_facet | María León-López Daniel Cabanillas-Balsera Victoria Areal-Quecuty Jenifer Martín-González María C. Jiménez-Sánchez Juan J. Saúco-Márquez Benito Sánchez-Domínguez Juan J. Segura-Egea |
author_sort | María León-López |
collection | DOAJ |
description | Aim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according to the PRISMA checklist, using the following databases: PubMed, Science Direct, Scopus, and Web of Science. Studies related to WL determination using EAL both in preflared and unflared root canals of extracted human teeth were included. The outcome of interest was the accuracy of the electronic WL determination. A quality assessment of the included studies was performed, determining the risk of bias. The meta-analyses were calculated with the 5.4 RevMan software using the inverse variance method with random effects. PROSPERO registration: CRD42021243412. Results. Ten experimental studies fulfilled the inclusion criteria, and most of them found that preflaring increases the accuracy of the EALs in WL determination. The calculated OR was 1.98 (95% CI = 1.65–2.37; <i>p</i> < 0.00001; I<sup>2</sup> = 10%), indicating that the determination of WL by EALs is almost twice as accurate in preflared canals. The accuracy of Root ZX in WL determination increases more than three times (OR = 3.25; <i>p</i> < 0.00001). Preflaring with Protaper files significantly increases the accuracy of EALs (OR = 1.76; <i>p</i> < 0.00001). The total risk of bias of the included studies was low. No obvious publication bias was observed. Conclusions. The results indicate a significant increase in the accuracy of WL determination with EAL after preflaring, doubling the percentage of exact measurements. Preflaring should be recommended as an important step during mechanical enlargement of the root canal, not only because it improves the access of the files to the canal, but also because it allows one to obtain more accurate electronic determinations of WL. |
first_indexed | 2024-03-10T10:07:25Z |
format | Article |
id | doaj.art-4f3e90fcfb4b4a198f0e0d7bdf787260 |
institution | Directory Open Access Journal |
issn | 2077-0383 |
language | English |
last_indexed | 2024-03-10T10:07:25Z |
publishDate | 2021-06-01 |
publisher | MDPI AG |
record_format | Article |
series | Journal of Clinical Medicine |
spelling | doaj.art-4f3e90fcfb4b4a198f0e0d7bdf7872602023-11-22T01:24:14ZengMDPI AGJournal of Clinical Medicine2077-03832021-06-011013276010.3390/jcm10132760Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-AnalysisMaría León-López0Daniel Cabanillas-Balsera1Victoria Areal-Quecuty2Jenifer Martín-González3María C. Jiménez-Sánchez4Juan J. Saúco-Márquez5Benito Sánchez-Domínguez6Juan J. Segura-Egea7Endodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainEndodontic Section, Department of Stomatology, University of Sevilla, C/Avicena s/n, 41009 Sevilla, SpainAim. To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL? Material and Methods. A systematic review was conducted according to the PRISMA checklist, using the following databases: PubMed, Science Direct, Scopus, and Web of Science. Studies related to WL determination using EAL both in preflared and unflared root canals of extracted human teeth were included. The outcome of interest was the accuracy of the electronic WL determination. A quality assessment of the included studies was performed, determining the risk of bias. The meta-analyses were calculated with the 5.4 RevMan software using the inverse variance method with random effects. PROSPERO registration: CRD42021243412. Results. Ten experimental studies fulfilled the inclusion criteria, and most of them found that preflaring increases the accuracy of the EALs in WL determination. The calculated OR was 1.98 (95% CI = 1.65–2.37; <i>p</i> < 0.00001; I<sup>2</sup> = 10%), indicating that the determination of WL by EALs is almost twice as accurate in preflared canals. The accuracy of Root ZX in WL determination increases more than three times (OR = 3.25; <i>p</i> < 0.00001). Preflaring with Protaper files significantly increases the accuracy of EALs (OR = 1.76; <i>p</i> < 0.00001). The total risk of bias of the included studies was low. No obvious publication bias was observed. Conclusions. The results indicate a significant increase in the accuracy of WL determination with EAL after preflaring, doubling the percentage of exact measurements. Preflaring should be recommended as an important step during mechanical enlargement of the root canal, not only because it improves the access of the files to the canal, but also because it allows one to obtain more accurate electronic determinations of WL.https://www.mdpi.com/2077-0383/10/13/2760cervical preflaringcoronal preflaringelectronic apex locatorpreflaringroot canal treatmentworking length |
spellingShingle | María León-López Daniel Cabanillas-Balsera Victoria Areal-Quecuty Jenifer Martín-González María C. Jiménez-Sánchez Juan J. Saúco-Márquez Benito Sánchez-Domínguez Juan J. Segura-Egea Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis Journal of Clinical Medicine cervical preflaring coronal preflaring electronic apex locator preflaring root canal treatment working length |
title | Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis |
title_full | Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis |
title_fullStr | Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis |
title_full_unstemmed | Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis |
title_short | Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis |
title_sort | influence of coronal preflaring on the accuracy of electronic working length determination systematic review and meta analysis |
topic | cervical preflaring coronal preflaring electronic apex locator preflaring root canal treatment working length |
url | https://www.mdpi.com/2077-0383/10/13/2760 |
work_keys_str_mv | AT marialeonlopez influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT danielcabanillasbalsera influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT victoriaarealquecuty influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT jenifermartingonzalez influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT mariacjimenezsanchez influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT juanjsaucomarquez influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT benitosanchezdominguez influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis AT juanjseguraegea influenceofcoronalpreflaringontheaccuracyofelectronicworkinglengthdeterminationsystematicreviewandmetaanalysis |