Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments

Compliance with the algorithms of endodontic treatment in most cases ensures the quality of treatment. However, real, long-term and sometimes immediate results that occur in clinical practice are not always successful. In general, the main reason for the unfavorable outcome of dental treatment is an...

Full description

Bibliographic Details
Main Authors: I. V. Pyatkova, L. Yu. Orekhova, T. V. Porkhun, A. V. Silin
Format: Article
Language:Russian
Published: LLC "Endo Press" 2020-04-01
Series:Эндодонтия Today
Subjects:
Online Access:https://www.endodont.ru/jour/article/view/856
_version_ 1797880093286072320
author I. V. Pyatkova
L. Yu. Orekhova
T. V. Porkhun
A. V. Silin
author_facet I. V. Pyatkova
L. Yu. Orekhova
T. V. Porkhun
A. V. Silin
author_sort I. V. Pyatkova
collection DOAJ
description Compliance with the algorithms of endodontic treatment in most cases ensures the quality of treatment. However, real, long-term and sometimes immediate results that occur in clinical practice are not always successful. In general, the main reason for the unfavorable outcome of dental treatment is an incomplete sanitation of the root canal system. Modern publications by J. F. Siqueira, I. N. Rocas, and D. Ricucci (2019) note that many issues of endodontic treatment are unresolved. It follows that improving the quality of endodontic treatment is still relevant.Aim. To compare two systems of instruments for root canal preparation with different types of rotation.Materials and methods. To identify a tool that will increase the efficiency of root canal preparation, taking into account their anatomy using CBCT, 24 teeth were removed, taken according to orthodontic or pristidintic indications, without previous endodontic treatment. Among them there were 2 incisors, 1 canine, 6 premolars, 15 molars. In total, 60 canals were examined.Results. The shape changes throughout the canal, turning into a round, oval, slit-like, complementing the configuration by the isthmuses between the canals in 13.3% of cases. WaveOne Gold showed a change in cross-sectional shape after preparation, while ProTaper Universal retained a rounded section of 6.67% after preparation of the slit-like channels.Conclusion. Identified priority technique of root canal preparation, allowing to reduce the number of instruments and, as a consequence, the possibility of technological failures in the root canal to reduce machining of the mouth of the channel, retaining dentine playing a major role in the further prosthesis and positive prediction of remote results.
first_indexed 2024-04-10T02:58:58Z
format Article
id doaj.art-4f61879d8f114e12a4bf9549ee0b9868
institution Directory Open Access Journal
issn 1683-2981
1726-7242
language Russian
last_indexed 2024-04-10T02:58:58Z
publishDate 2020-04-01
publisher LLC "Endo Press"
record_format Article
series Эндодонтия Today
spelling doaj.art-4f61879d8f114e12a4bf9549ee0b98682023-03-13T07:39:26ZrusLLC "Endo Press"Эндодонтия Today1683-29811726-72422020-04-01181212610.36377/1683-2981-2020-18-1-21-26840Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instrumentsI. V. Pyatkova0L. Yu. Orekhova1T. V. Porkhun2A. V. Silin3ГБОУ ВО СЗГМУ им. И.И.Мечникова Минздрава РоссииПСПГМУ им. акад. им. И.П. ПавловаПСПГМУ им. акад. им. И.П. ПавловаГБОУ ВО СЗГМУ им. И.И.Мечникова Минздрава РоссииCompliance with the algorithms of endodontic treatment in most cases ensures the quality of treatment. However, real, long-term and sometimes immediate results that occur in clinical practice are not always successful. In general, the main reason for the unfavorable outcome of dental treatment is an incomplete sanitation of the root canal system. Modern publications by J. F. Siqueira, I. N. Rocas, and D. Ricucci (2019) note that many issues of endodontic treatment are unresolved. It follows that improving the quality of endodontic treatment is still relevant.Aim. To compare two systems of instruments for root canal preparation with different types of rotation.Materials and methods. To identify a tool that will increase the efficiency of root canal preparation, taking into account their anatomy using CBCT, 24 teeth were removed, taken according to orthodontic or pristidintic indications, without previous endodontic treatment. Among them there were 2 incisors, 1 canine, 6 premolars, 15 molars. In total, 60 canals were examined.Results. The shape changes throughout the canal, turning into a round, oval, slit-like, complementing the configuration by the isthmuses between the canals in 13.3% of cases. WaveOne Gold showed a change in cross-sectional shape after preparation, while ProTaper Universal retained a rounded section of 6.67% after preparation of the slit-like channels.Conclusion. Identified priority technique of root canal preparation, allowing to reduce the number of instruments and, as a consequence, the possibility of technological failures in the root canal to reduce machining of the mouth of the channel, retaining dentine playing a major role in the further prosthesis and positive prediction of remote results.https://www.endodont.ru/jour/article/view/856конусно-лучевая компьютерная томографияанатомия корневых каналовкривизна корневого каналаникель-титановые инструментыпрепарированиепломбирование корневых каналов
spellingShingle I. V. Pyatkova
L. Yu. Orekhova
T. V. Porkhun
A. V. Silin
Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
Эндодонтия Today
конусно-лучевая компьютерная томография
анатомия корневых каналов
кривизна корневого канала
никель-титановые инструменты
препарирование
пломбирование корневых каналов
title Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
title_full Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
title_fullStr Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
title_full_unstemmed Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
title_short Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
title_sort determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments
topic конусно-лучевая компьютерная томография
анатомия корневых каналов
кривизна корневого канала
никель-титановые инструменты
препарирование
пломбирование корневых каналов
url https://www.endodont.ru/jour/article/view/856
work_keys_str_mv AT ivpyatkova determinationofindicationsforthechoiceofthepreparationmethodoftherootcanalsystemwithrotationandreciprocationinstruments
AT lyuorekhova determinationofindicationsforthechoiceofthepreparationmethodoftherootcanalsystemwithrotationandreciprocationinstruments
AT tvporkhun determinationofindicationsforthechoiceofthepreparationmethodoftherootcanalsystemwithrotationandreciprocationinstruments
AT avsilin determinationofindicationsforthechoiceofthepreparationmethodoftherootcanalsystemwithrotationandreciprocationinstruments