Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture

Purpose: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing fle...

Full description

Bibliographic Details
Main Authors: Rukmanikanthan Shanmugam, Chong Yin Chyi@ Chong Shyh Jian, Amber Haseeb, Saw Aik
Format: Article
Language:English
Published: SAGE Publishing 2018-09-01
Series:Journal of Orthopaedic Surgery
Online Access:https://doi.org/10.1177/2309499018802511
_version_ 1828518991382970368
author Rukmanikanthan Shanmugam
Chong Yin Chyi@ Chong Shyh Jian
Amber Haseeb
Saw Aik
author_facet Rukmanikanthan Shanmugam
Chong Yin Chyi@ Chong Shyh Jian
Amber Haseeb
Saw Aik
author_sort Rukmanikanthan Shanmugam
collection DOAJ
description Purpose: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion. Method: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion. Results: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group. Conclusion: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.
first_indexed 2024-12-11T19:05:36Z
format Article
id doaj.art-4f9220fbfa4f4960a14c554074d8b1e9
institution Directory Open Access Journal
issn 2309-4990
language English
last_indexed 2024-12-11T19:05:36Z
publishDate 2018-09-01
publisher SAGE Publishing
record_format Article
series Journal of Orthopaedic Surgery
spelling doaj.art-4f9220fbfa4f4960a14c554074d8b1e92022-12-22T00:53:55ZengSAGE PublishingJournal of Orthopaedic Surgery2309-49902018-09-012610.1177/2309499018802511Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fractureRukmanikanthan ShanmugamChong Yin Chyi@ Chong Shyh JianAmber HaseebSaw AikPurpose: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion. Method: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion. Results: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group. Conclusion: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.https://doi.org/10.1177/2309499018802511
spellingShingle Rukmanikanthan Shanmugam
Chong Yin Chyi@ Chong Shyh Jian
Amber Haseeb
Saw Aik
Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
Journal of Orthopaedic Surgery
title Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
title_full Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
title_fullStr Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
title_full_unstemmed Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
title_short Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
title_sort comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture
url https://doi.org/10.1177/2309499018802511
work_keys_str_mv AT rukmanikanthanshanmugam comparingbiomechanicalstrengthofunicorticallockingplateversusbicorticalcompressionplatefortransversemidshaftmetacarpalfracture
AT chongyinchyichongshyhjian comparingbiomechanicalstrengthofunicorticallockingplateversusbicorticalcompressionplatefortransversemidshaftmetacarpalfracture
AT amberhaseeb comparingbiomechanicalstrengthofunicorticallockingplateversusbicorticalcompressionplatefortransversemidshaftmetacarpalfracture
AT sawaik comparingbiomechanicalstrengthofunicorticallockingplateversusbicorticalcompressionplatefortransversemidshaftmetacarpalfracture