Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report
Coronal malalignment due to malrotated trochanteric nail placement in femoral fracture fixation has never been reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Malaysian Orthopaedic Association
2020-03-01
|
Series: | Malaysian Orthopaedic Journal |
Subjects: | |
Online Access: | https://www.morthoj.org/2020/v14n1/malalignment-malrotated.pdf |
_version_ | 1819134772622917632 |
---|---|
author | Hwang PX Anuwar NA Khaw YC Hadizie D |
author_facet | Hwang PX Anuwar NA Khaw YC Hadizie D |
author_sort | Hwang PX |
collection | DOAJ |
description | Coronal malalignment due to malrotated trochanteric nail
placement in femoral fracture fixation has never been
reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a rotational malalignment. Knowledge of the modern nail design with proper intra-operative precautions, would avoid this underestimated technical error. |
first_indexed | 2024-12-22T10:08:30Z |
format | Article |
id | doaj.art-4fc51dcae40141f0bc591d7b6d924515 |
institution | Directory Open Access Journal |
issn | 1985-2533 2232-111X |
language | English |
last_indexed | 2024-12-22T10:08:30Z |
publishDate | 2020-03-01 |
publisher | Malaysian Orthopaedic Association |
record_format | Article |
series | Malaysian Orthopaedic Journal |
spelling | doaj.art-4fc51dcae40141f0bc591d7b6d9245152022-12-21T18:29:56ZengMalaysian Orthopaedic AssociationMalaysian Orthopaedic Journal1985-25332232-111X2020-03-01141747710.5704/MOJ.2003.011Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case ReportHwang PX0Anuwar NA1Khaw YC2Hadizie D3MBBSMBBSMDMMed OrthoCoronal malalignment due to malrotated trochanteric nail placement in femoral fracture fixation has never been reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a rotational malalignment. Knowledge of the modern nail design with proper intra-operative precautions, would avoid this underestimated technical error.https://www.morthoj.org/2020/v14n1/malalignment-malrotated.pdfvalgusnailmalalignmentmalunionmalrotated |
spellingShingle | Hwang PX Anuwar NA Khaw YC Hadizie D Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report Malaysian Orthopaedic Journal valgus nail malalignment malunion malrotated |
title | Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report |
title_full | Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report |
title_fullStr | Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report |
title_full_unstemmed | Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report |
title_short | Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report |
title_sort | valgus malalignment due to internally malrotated trochanteric nail placement with rotational malalignment in femoral shaft segmental fracture fixation an underestimated avoidable technical error a case report |
topic | valgus nail malalignment malunion malrotated |
url | https://www.morthoj.org/2020/v14n1/malalignment-malrotated.pdf |
work_keys_str_mv | AT hwangpx valgusmalalignmentduetointernallymalrotatedtrochantericnailplacementwithrotationalmalalignmentinfemoralshaftsegmentalfracturefixationanunderestimatedavoidabletechnicalerroracasereport AT anuwarna valgusmalalignmentduetointernallymalrotatedtrochantericnailplacementwithrotationalmalalignmentinfemoralshaftsegmentalfracturefixationanunderestimatedavoidabletechnicalerroracasereport AT khawyc valgusmalalignmentduetointernallymalrotatedtrochantericnailplacementwithrotationalmalalignmentinfemoralshaftsegmentalfracturefixationanunderestimatedavoidabletechnicalerroracasereport AT hadizied valgusmalalignmentduetointernallymalrotatedtrochantericnailplacementwithrotationalmalalignmentinfemoralshaftsegmentalfracturefixationanunderestimatedavoidabletechnicalerroracasereport |