Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone

A bone conduction (BC) sound presented on either side of the head will travel to the cochleae in both ears, and this crosstalk phenomenon is considered one factor limiting the benefits of binaural hearing with BC. Previous studies have demonstrated the feasibility of measuring the phase and level re...

Full description

Bibliographic Details
Main Authors: Irwansyah, Sho Otsuka, Seiji Nakagawa
Format: Article
Language:English
Published: IEEE 2022-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9841568/
_version_ 1818537692379480064
author Irwansyah
Sho Otsuka
Seiji Nakagawa
author_facet Irwansyah
Sho Otsuka
Seiji Nakagawa
author_sort Irwansyah
collection DOAJ
description A bone conduction (BC) sound presented on either side of the head will travel to the cochleae in both ears, and this crosstalk phenomenon is considered one factor limiting the benefits of binaural hearing with BC. Previous studies have demonstrated the feasibility of measuring the phase and level required for crosstalk cancellation at the cochlea; however, given a human subject’s inability to consistently detect low frequencies, this method is limited to cancellations at frequencies above 1000 Hz. This study describes an alternative approach for implementing a crosstalk cancellation system for low frequencies by measuring ear-canal sound pressure (ECSP). Since the ear canal is close to the cochlea, we hypothesized that altering ECSP in response to a BC stimulation may be used to achieve crosstalk cancellation at the cochlea. Our approach relies on ECSP measurements to estimate impulse responses (IRs) from bone transducers to a probe microphone in the ear canal. The IRs are then used to predict the phase and level required for crosstalk cancellation at the probe microphone’s location. To confirm the hypothesis, we measured tone reception threshold (TRT), the lowest tone level participants could detect, under two conditions: with and without crosstalk cancellation. Although crosstalk cancellation was designed to occur at the probe microphone and not at the cochlea, the TRT results showed that participants were still able to perceive cancellations at frequencies below 1000 Hz.
first_indexed 2024-12-11T18:54:01Z
format Article
id doaj.art-4fe54d1696e644fbbcbf6f145ce0acf0
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-12-11T18:54:01Z
publishDate 2022-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-4fe54d1696e644fbbcbf6f145ce0acf02022-12-22T00:54:13ZengIEEEIEEE Access2169-35362022-01-0110792017921210.1109/ACCESS.2022.31941719841568Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone Irwansyah0https://orcid.org/0000-0001-5702-3279Sho Otsuka1Seiji Nakagawa2Center for Frontier Medical Engineering, Chiba University, Chiba, JapanCenter for Frontier Medical Engineering, Chiba University, Chiba, JapanCenter for Frontier Medical Engineering, Chiba University, Chiba, JapanA bone conduction (BC) sound presented on either side of the head will travel to the cochleae in both ears, and this crosstalk phenomenon is considered one factor limiting the benefits of binaural hearing with BC. Previous studies have demonstrated the feasibility of measuring the phase and level required for crosstalk cancellation at the cochlea; however, given a human subject’s inability to consistently detect low frequencies, this method is limited to cancellations at frequencies above 1000 Hz. This study describes an alternative approach for implementing a crosstalk cancellation system for low frequencies by measuring ear-canal sound pressure (ECSP). Since the ear canal is close to the cochlea, we hypothesized that altering ECSP in response to a BC stimulation may be used to achieve crosstalk cancellation at the cochlea. Our approach relies on ECSP measurements to estimate impulse responses (IRs) from bone transducers to a probe microphone in the ear canal. The IRs are then used to predict the phase and level required for crosstalk cancellation at the probe microphone’s location. To confirm the hypothesis, we measured tone reception threshold (TRT), the lowest tone level participants could detect, under two conditions: with and without crosstalk cancellation. Although crosstalk cancellation was designed to occur at the probe microphone and not at the cochlea, the TRT results showed that participants were still able to perceive cancellations at frequencies below 1000 Hz.https://ieeexplore.ieee.org/document/9841568/Bone conductionbone transducercrosstalk cancellationprobe microphone
spellingShingle Irwansyah
Sho Otsuka
Seiji Nakagawa
Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone
IEEE Access
Bone conduction
bone transducer
crosstalk cancellation
probe microphone
title Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone
title_full Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone
title_fullStr Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone
title_full_unstemmed Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone
title_short Improved Low-Frequency Crosstalk Cancellation in Bone Conduction Using Bone Transducers and Probe Microphone
title_sort improved low frequency crosstalk cancellation in bone conduction using bone transducers and probe microphone
topic Bone conduction
bone transducer
crosstalk cancellation
probe microphone
url https://ieeexplore.ieee.org/document/9841568/
work_keys_str_mv AT irwansyah improvedlowfrequencycrosstalkcancellationinboneconductionusingbonetransducersandprobemicrophone
AT shootsuka improvedlowfrequencycrosstalkcancellationinboneconductionusingbonetransducersandprobemicrophone
AT seijinakagawa improvedlowfrequencycrosstalkcancellationinboneconductionusingbonetransducersandprobemicrophone