Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation
Due to the increasing injection of intermittent power sources (solar+wind) into a common grid, dispatchable sources such as hydro power should be able to help reduce the variability in load and the variability in generation caused by the intermittent sources. A hydro generator should be a...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2022-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9902962/ |
_version_ | 1811195904600834048 |
---|---|
author | Madhusudhan Pandey Bernt Lie |
author_facet | Madhusudhan Pandey Bernt Lie |
author_sort | Madhusudhan Pandey |
collection | DOAJ |
description | Due to the increasing injection of intermittent power sources (solar+wind) into a common grid, dispatchable sources such as hydro power should be able to help reduce the variability in load and the variability in generation caused by the intermittent sources. A hydro generator should be able to operate short-term beyond its thermal capability limit. This requires the monitoring of internal temperatures in the hydro generator. In this paper, a thermal model of an air-cooled synchronous generator is presented, emphasizing the various aspects of parameter estimation and identifiability using Bayesian inference. Inferences are drawn from the posterior distributions of the parameters and initial conditions, dispersion (spreading) of particles and sampling efficiency, practical parameter identifiability, and model mismatch with experiments. Results show extremely narrow parameter distributions. It is early to generalize about the posterior distribution of air-related and metal-related parameters of the air-cooled synchronous generator based on the single experimental data presented here. |
first_indexed | 2024-04-12T00:51:29Z |
format | Article |
id | doaj.art-501075c050a44eddb577a0a307493970 |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-04-12T00:51:29Z |
publishDate | 2022-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-501075c050a44eddb577a0a3074939702022-12-22T03:54:44ZengIEEEIEEE Access2169-35362022-01-011010352910353710.1109/ACCESS.2022.32092329902962Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter EstimationMadhusudhan Pandey0Bernt Lie1https://orcid.org/0000-0001-5967-4411Telemark Modeling and Control Center (TMCC), Porsgrunn, NorwayTelemark Modeling and Control Center (TMCC), Porsgrunn, NorwayDue to the increasing injection of intermittent power sources (solar+wind) into a common grid, dispatchable sources such as hydro power should be able to help reduce the variability in load and the variability in generation caused by the intermittent sources. A hydro generator should be able to operate short-term beyond its thermal capability limit. This requires the monitoring of internal temperatures in the hydro generator. In this paper, a thermal model of an air-cooled synchronous generator is presented, emphasizing the various aspects of parameter estimation and identifiability using Bayesian inference. Inferences are drawn from the posterior distributions of the parameters and initial conditions, dispersion (spreading) of particles and sampling efficiency, practical parameter identifiability, and model mismatch with experiments. Results show extremely narrow parameter distributions. It is early to generalize about the posterior distribution of air-related and metal-related parameters of the air-cooled synchronous generator based on the single experimental data presented here.https://ieeexplore.ieee.org/document/9902962/Bayesian inferencemodel fittingparameter estimationparameter identifiabilitysynchronous generatorthermal model |
spellingShingle | Madhusudhan Pandey Bernt Lie Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation IEEE Access Bayesian inference model fitting parameter estimation parameter identifiability synchronous generator thermal model |
title | Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation |
title_full | Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation |
title_fullStr | Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation |
title_full_unstemmed | Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation |
title_short | Bayesian Inference for Thermal Model of Synchronous Generator—Part I: Parameter Estimation |
title_sort | bayesian inference for thermal model of synchronous generator x2014 part i parameter estimation |
topic | Bayesian inference model fitting parameter estimation parameter identifiability synchronous generator thermal model |
url | https://ieeexplore.ieee.org/document/9902962/ |
work_keys_str_mv | AT madhusudhanpandey bayesianinferenceforthermalmodelofsynchronousgeneratorx2014partiparameterestimation AT berntlie bayesianinferenceforthermalmodelofsynchronousgeneratorx2014partiparameterestimation |