<p>Abstract</p> <p>Introduction</p> <p>A tracheobronchial foreign body is a rarely mentioned cause of massive hemoptysis. Although an aspirated toothpick is a well-known cause of traumatic injury to the respiratory tract, a similar device called a dental floss pick, whi...

Full description

Bibliographic Details
Main Authors: Huang Chun-Ta, Ho Chao-Chi, Tsai Yi-Ju, Yang Pan-Chyr
Format: Article
Language:English
Published: BMC 2008-03-01
Series:Journal of Medical Case Reports
Online Access:http://www.jmedicalcasereports.com/content/2/1/78
Description
Summary:<p>Abstract</p> <p>Introduction</p> <p>A tracheobronchial foreign body is a rarely mentioned cause of massive hemoptysis. Although an aspirated toothpick is a well-known cause of traumatic injury to the respiratory tract, a similar device called a dental floss pick, which is much larger than a toothpick, has never been described as a tracheobronchial foreign body.</p> <p>Case presentation</p> <p>We report a case of massive hemoptysis in a 32-year-old man due to a dental floss pick in the left main bronchus. Flexible fiberoptic bronchoscopy was successful in removing the foreign body.</p> <p>Conclusion</p> <p>Tracheobronchial foreign body can be a medical emergency requiring immediate intervention and massive hemoptysis may be the presenting symptom. Flexible fiberoptic bronchoscopy is recommended as the first-line treatment modality for tracheobronchial foreign body removal. A dental floss pick may present as a tracheobronchial foreign body and can reside in the airway asymptomatically for many years.</p>