Open-circuit fault diagnosis of three-level inverter based on Park transformatio

In view of problems that existing neutral point clamped (NPC) three-level inverter fault diagnosis method needs large amount of calculation and its accuracy is affected by noise and load, an open-circuit fault diagnosis method of three-level inverter based on Park transformation was proposed. Park t...

Full description

Bibliographic Details
Main Authors: REN Xiaohong, WAN Hong, YU Xiao, DING Enjie
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2020-05-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17523
_version_ 1819018008406786048
author REN Xiaohong
WAN Hong
YU Xiao
DING Enjie
author_facet REN Xiaohong
WAN Hong
YU Xiao
DING Enjie
author_sort REN Xiaohong
collection DOAJ
description In view of problems that existing neutral point clamped (NPC) three-level inverter fault diagnosis method needs large amount of calculation and its accuracy is affected by noise and load, an open-circuit fault diagnosis method of three-level inverter based on Park transformation was proposed. Park transformation is carried out on three-phase output current of the three-level inverter to calculate average current Park vector;sliding window is used to obtain a single-cycle current signal, and output current change is analyzed in case of IGBT fault according to inverter circuit structure; iterative method is used to determine threshold value of average current Park vector modulus, and 13 kinds of open-circuit faults of three-level inverter power tube are identifid and located combining phase angle and modulus.Simulation results show that the fault diagnosis accuracy of the method reaches 98.31%. Compared with traditional open-circuit fault diagnosis method, the proposed method does not need to learn and train the data of 13 kinds of open-circuit faults, which greatly reduces calculation amount and improves efficiency and accuracy of fault diagnosis.
first_indexed 2024-12-21T03:12:35Z
format Article
id doaj.art-50e756d381f3496c9fa197062f0ebef6
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-12-21T03:12:35Z
publishDate 2020-05-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-50e756d381f3496c9fa197062f0ebef62022-12-21T19:17:56ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2020-05-01465828610.13272/j.issn.1671-251x.17523Open-circuit fault diagnosis of three-level inverter based on Park transformatioREN XiaohongWAN HongYU XiaoDING EnjieIn view of problems that existing neutral point clamped (NPC) three-level inverter fault diagnosis method needs large amount of calculation and its accuracy is affected by noise and load, an open-circuit fault diagnosis method of three-level inverter based on Park transformation was proposed. Park transformation is carried out on three-phase output current of the three-level inverter to calculate average current Park vector;sliding window is used to obtain a single-cycle current signal, and output current change is analyzed in case of IGBT fault according to inverter circuit structure; iterative method is used to determine threshold value of average current Park vector modulus, and 13 kinds of open-circuit faults of three-level inverter power tube are identifid and located combining phase angle and modulus.Simulation results show that the fault diagnosis accuracy of the method reaches 98.31%. Compared with traditional open-circuit fault diagnosis method, the proposed method does not need to learn and train the data of 13 kinds of open-circuit faults, which greatly reduces calculation amount and improves efficiency and accuracy of fault diagnosis.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17523npc three-level inverterigbt power tube open-circuit faultpark transformationaverage current park vector
spellingShingle REN Xiaohong
WAN Hong
YU Xiao
DING Enjie
Open-circuit fault diagnosis of three-level inverter based on Park transformatio
Gong-kuang zidonghua
npc three-level inverter
igbt power tube open-circuit fault
park transformation
average current park vector
title Open-circuit fault diagnosis of three-level inverter based on Park transformatio
title_full Open-circuit fault diagnosis of three-level inverter based on Park transformatio
title_fullStr Open-circuit fault diagnosis of three-level inverter based on Park transformatio
title_full_unstemmed Open-circuit fault diagnosis of three-level inverter based on Park transformatio
title_short Open-circuit fault diagnosis of three-level inverter based on Park transformatio
title_sort open circuit fault diagnosis of three level inverter based on park transformatio
topic npc three-level inverter
igbt power tube open-circuit fault
park transformation
average current park vector
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17523
work_keys_str_mv AT renxiaohong opencircuitfaultdiagnosisofthreelevelinverterbasedonparktransformatio
AT wanhong opencircuitfaultdiagnosisofthreelevelinverterbasedonparktransformatio
AT yuxiao opencircuitfaultdiagnosisofthreelevelinverterbasedonparktransformatio
AT dingenjie opencircuitfaultdiagnosisofthreelevelinverterbasedonparktransformatio