BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER

This study includes a series of bond tests related to reinforced concrete beams with rectangular cross section (140x150) & span of 600 mm that are provided with shear reinforcement. The specimens are tested as simply supported beams with one point load with strain reading in steel bar by strain...

Full description

Bibliographic Details
Main Authors: Ali Mijbel Al-Athary, Ghazi Faisal kheder, Suha Rasheed Abass
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2019-11-01
Series:Journal of Engineering and Sustainable Development
Subjects:
Online Access:http://www.jeasd.org/images/issue_5/12.pdf
_version_ 1811215237191303168
author Ali Mijbel Al-Athary
Ghazi Faisal kheder
Suha Rasheed Abass
author_facet Ali Mijbel Al-Athary
Ghazi Faisal kheder
Suha Rasheed Abass
author_sort Ali Mijbel Al-Athary
collection DOAJ
description This study includes a series of bond tests related to reinforced concrete beams with rectangular cross section (140x150) & span of 600 mm that are provided with shear reinforcement. The specimens are tested as simply supported beams with one point load with strain reading in steel bar by strain indicator placed in a hole (recess) prepared for this purpose. Displacement between the steel bar and the concrete at the free end of bar has been measured. Three groups of beams have been tested to study the effect of many variables on bond strength for Self Compacting Concrete (SCC ) and conventional reinforced concrete (CC). The variables are: [steel bar diameter (8, 12 and 16) mm, concrete compressive strength (30, 60) MPa and type of curing (tap water continuous curing, saline water wetting and drying, saline water continuous exposing) for a time of (90 days). The study also involves the effect of each variable on bond strength and comparison between the results of all the specimens of SCC and CC bond stress-slip relationships. The results of comparison between all specimens of SCC and CC bond stress-slip relationships show that, the CC bond strength is lower than the SCC bond strength in two cases of curing (tap water continuous, saline water continuous exposing), but in case of saline water wetting and drying, the CC bond strength is higher than SCC bond strength
first_indexed 2024-04-12T06:17:56Z
format Article
id doaj.art-5119f32e871741f8bf6dc86e203ff4d8
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-04-12T06:17:56Z
publishDate 2019-11-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-5119f32e871741f8bf6dc86e203ff4d82022-12-22T03:44:23ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252019-11-01230517219210.31272/jeasd.23.5.12BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATERAli Mijbel Al-Athary 0Ghazi Faisal kheder 1Suha Rasheed Abass2Assistant prof., Civil Engineering Department, Mustansiriyah University, Baghdad, IraqProf. Civil Engineering Department, Mustansiriyah University, Baghdad, IraqLecturer, Civil Engineering Department, Mustansiriyah University, Baghdad, IraqThis study includes a series of bond tests related to reinforced concrete beams with rectangular cross section (140x150) & span of 600 mm that are provided with shear reinforcement. The specimens are tested as simply supported beams with one point load with strain reading in steel bar by strain indicator placed in a hole (recess) prepared for this purpose. Displacement between the steel bar and the concrete at the free end of bar has been measured. Three groups of beams have been tested to study the effect of many variables on bond strength for Self Compacting Concrete (SCC ) and conventional reinforced concrete (CC). The variables are: [steel bar diameter (8, 12 and 16) mm, concrete compressive strength (30, 60) MPa and type of curing (tap water continuous curing, saline water wetting and drying, saline water continuous exposing) for a time of (90 days). The study also involves the effect of each variable on bond strength and comparison between the results of all the specimens of SCC and CC bond stress-slip relationships. The results of comparison between all specimens of SCC and CC bond stress-slip relationships show that, the CC bond strength is lower than the SCC bond strength in two cases of curing (tap water continuous, saline water continuous exposing), but in case of saline water wetting and drying, the CC bond strength is higher than SCC bond strengthhttp://www.jeasd.org/images/issue_5/12.pdfbond strengthself compacting & conventional concretebeam testexposing saline water
spellingShingle Ali Mijbel Al-Athary
Ghazi Faisal kheder
Suha Rasheed Abass
BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER
Journal of Engineering and Sustainable Development
bond strength
self compacting & conventional concrete
beam test
exposing saline water
title BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER
title_full BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER
title_fullStr BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER
title_full_unstemmed BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER
title_short BOND STRENGTH OF SELF-COMPACTING REINFORCED CONCRETE BEAMS EXPOSED TO SALINE WATER
title_sort bond strength of self compacting reinforced concrete beams exposed to saline water
topic bond strength
self compacting & conventional concrete
beam test
exposing saline water
url http://www.jeasd.org/images/issue_5/12.pdf
work_keys_str_mv AT alimijbelalathary bondstrengthofselfcompactingreinforcedconcretebeamsexposedtosalinewater
AT ghazifaisalkheder bondstrengthofselfcompactingreinforcedconcretebeamsexposedtosalinewater
AT suharasheedabass bondstrengthofselfcompactingreinforcedconcretebeamsexposedtosalinewater