Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system

The main purpose of the article is to develop a multifactorial model for rapid assessment of the efficiency of biological wastewater treatment reactors. A mathematical model of the process of biological wastewater treatment has been developed based on: changes in the concentration of organic contami...

Full description

Bibliographic Details
Main Authors: Andrii Safonyk, Oleg Rogov, Maksym Trokhymchuk, Olena Prysiazhniuk, Ihor Prysiazhniuk
Format: Article
Language:English
Published: Polish Academy of Sciences 2024-03-01
Series:Journal of Water and Land Development
Subjects:
Online Access:https://journals.pan.pl/Content/130589/2024-01-JWLD-04.pdf
_version_ 1797238953022062592
author Andrii Safonyk
Oleg Rogov
Maksym Trokhymchuk
Olena Prysiazhniuk
Ihor Prysiazhniuk
author_facet Andrii Safonyk
Oleg Rogov
Maksym Trokhymchuk
Olena Prysiazhniuk
Ihor Prysiazhniuk
author_sort Andrii Safonyk
collection DOAJ
description The main purpose of the article is to develop a multifactorial model for rapid assessment of the efficiency of biological wastewater treatment reactors. A mathematical model of the process of biological wastewater treatment has been developed based on: changes in the concentration of organic contaminants in the bioreactor over time, taking into account the uneven flow of wastewater to the treatment plant, the process of substrate entering the bioreactor (different amounts may enter at different times). The software implementation of the proposed algorithm for solving the corresponding model problem in Python is carried out. The results of computer experiments on the study of the efficiency of wastewater treatment in biological treatment reactors for different operating conditions of facilities are presented. In particular, such processes were considered with taking into account the unevenness of the load, because the maximum cleaning loads are in the morning and in the evening. The task was solved to simulate a real situation and show how cleaning takes place at the maximum load at a certain time of the day. The results obtained will be useful for calculations in the design of biological treatment facilities or in the reconstruction of existing bioreactors for their prospective operation under new operating conditions.
first_indexed 2024-04-24T17:43:49Z
format Article
id doaj.art-511b72560bb141db8f9ec1c0b4fac8e4
institution Directory Open Access Journal
issn 2083-4535
language English
last_indexed 2024-04-24T17:43:49Z
publishDate 2024-03-01
publisher Polish Academy of Sciences
record_format Article
series Journal of Water and Land Development
spelling doaj.art-511b72560bb141db8f9ec1c0b4fac8e42024-03-27T15:12:35ZengPolish Academy of SciencesJournal of Water and Land Development2083-45352024-03-01No 603238https://doi.org/10.24425/jwld.2023.148456Research of the process of biological wastewater treatment under conditions of uneven load of the treatment systemAndrii Safonyk0https://orcid.org/0000-0002-5020-9051Oleg Rogov1https://orcid.org/0009-0006-2821-4811Maksym Trokhymchuk2https://orcid.org/0009-0006-9891-4282Olena Prysiazhniuk3https://orcid.org/0000-0003-0003-3518Ihor Prysiazhniuk4https://orcid.org/0000-0003-4531-1788National University of Water and Environmental Engineering, Institute of Energy, Automatics and Water Management, Department of Automation, Electrical Engineering and Computer-integrated Technologies, 11 Soborna St, 33028, Rivne, UkraineNational University of Water and Environmental Engineering, Institute of Energy, Automatics and Water Management, Department of Automation, Electrical Engineering and Computer-integrated Technologies, 11 Soborna St, 33028, Rivne, UkraineNational University of Water and Environmental Engineering, Institute of Energy, Automatics and Water Management, Department of Automation, Electrical Engineering and Computer-integrated Technologies, 11 Soborna St, 33028, Rivne, UkraineNational University of Water and Environmental Engineering, Institute of Energy, Automatics and Water Management, Department of Automation, Electrical Engineering and Computer-integrated Technologies, 11 Soborna St, 33028, Rivne, UkraineRivne State University of Humanities, Faculty of Mathematics and Informatics, 31 Plastova St, 33000, Rivne, UkraineThe main purpose of the article is to develop a multifactorial model for rapid assessment of the efficiency of biological wastewater treatment reactors. A mathematical model of the process of biological wastewater treatment has been developed based on: changes in the concentration of organic contaminants in the bioreactor over time, taking into account the uneven flow of wastewater to the treatment plant, the process of substrate entering the bioreactor (different amounts may enter at different times). The software implementation of the proposed algorithm for solving the corresponding model problem in Python is carried out. The results of computer experiments on the study of the efficiency of wastewater treatment in biological treatment reactors for different operating conditions of facilities are presented. In particular, such processes were considered with taking into account the unevenness of the load, because the maximum cleaning loads are in the morning and in the evening. The task was solved to simulate a real situation and show how cleaning takes place at the maximum load at a certain time of the day. The results obtained will be useful for calculations in the design of biological treatment facilities or in the reconstruction of existing bioreactors for their prospective operation under new operating conditions.https://journals.pan.pl/Content/130589/2024-01-JWLD-04.pdfactivated sludge concentrationbiological wastewater treatment reactorsmathematical modelnonuniformity conditionsorganic contaminants
spellingShingle Andrii Safonyk
Oleg Rogov
Maksym Trokhymchuk
Olena Prysiazhniuk
Ihor Prysiazhniuk
Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
Journal of Water and Land Development
activated sludge concentration
biological wastewater treatment reactors
mathematical model
nonuniformity conditions
organic contaminants
title Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
title_full Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
title_fullStr Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
title_full_unstemmed Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
title_short Research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
title_sort research of the process of biological wastewater treatment under conditions of uneven load of the treatment system
topic activated sludge concentration
biological wastewater treatment reactors
mathematical model
nonuniformity conditions
organic contaminants
url https://journals.pan.pl/Content/130589/2024-01-JWLD-04.pdf
work_keys_str_mv AT andriisafonyk researchoftheprocessofbiologicalwastewatertreatmentunderconditionsofunevenloadofthetreatmentsystem
AT olegrogov researchoftheprocessofbiologicalwastewatertreatmentunderconditionsofunevenloadofthetreatmentsystem
AT maksymtrokhymchuk researchoftheprocessofbiologicalwastewatertreatmentunderconditionsofunevenloadofthetreatmentsystem
AT olenaprysiazhniuk researchoftheprocessofbiologicalwastewatertreatmentunderconditionsofunevenloadofthetreatmentsystem
AT ihorprysiazhniuk researchoftheprocessofbiologicalwastewatertreatmentunderconditionsofunevenloadofthetreatmentsystem