Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels
This technical note demonstrates the feasibility of using laser ablation inductively coupled plasma mass spectrometry for the characterization of U–7Mo/Al–5Si dispersion fuel. Our measurements show 5.0% Relative Standard Deviation (RSD) for the reproducibility of measured 98Mo/238U ratios in fuel pa...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2017-04-01
|
Series: | Nuclear Engineering and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1738573316301607 |
_version_ | 1818179807361368064 |
---|---|
author | Jeongmook Lee Jai Il Park Young-Sang Youn Yeong-Keong Ha Jong-Yun Kim |
author_facet | Jeongmook Lee Jai Il Park Young-Sang Youn Yeong-Keong Ha Jong-Yun Kim |
author_sort | Jeongmook Lee |
collection | DOAJ |
description | This technical note demonstrates the feasibility of using laser ablation inductively coupled plasma mass spectrometry for the characterization of U–7Mo/Al–5Si dispersion fuel. Our measurements show 5.0% Relative Standard Deviation (RSD) for the reproducibility of measured 98Mo/238U ratios in fuel particles from spot analysis, and 3.4% RSD for 98Mo/238U ratios in a NIST-SRM 612 glass standard. Line scanning allows for the distinction of U–7Mo fuel particles from the Al–5Si matrix. Each mass spectrum peak indicates the presence of U–7Mo fuel particles, and the time width of each peak corresponds to the size of that fuel particle. The size of the fuel particles is estimated from the time width of the mass spectrum peak for 98Mo by considering the scan rate used during the line scan. This preliminary application clearly demonstrates that laser ablation inductively coupled plasma mass spectrometry can directly identify isotope ratios and sizes of the fuel particles in U–Mo/Al dispersion fuel. Once optimized further, this instrument will be a powerful tool for investigating irradiated dispersion fuels in terms of fission product distributions in fuel matrices, and the changes in fuel particle size or shape after irradiation. |
first_indexed | 2024-12-11T21:09:44Z |
format | Article |
id | doaj.art-5129fd6350684eaa94d4833eb784315b |
institution | Directory Open Access Journal |
issn | 1738-5733 |
language | English |
last_indexed | 2024-12-11T21:09:44Z |
publishDate | 2017-04-01 |
publisher | Elsevier |
record_format | Article |
series | Nuclear Engineering and Technology |
spelling | doaj.art-5129fd6350684eaa94d4833eb784315b2022-12-22T00:50:45ZengElsevierNuclear Engineering and Technology1738-57332017-04-0149364565010.1016/j.net.2016.08.014Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion FuelsJeongmook Lee0Jai Il Park1Young-Sang Youn2Yeong-Keong Ha3Jong-Yun Kim4Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero, 989 Beon-gil, Yuseong-gu, Daejeon 34057, Republic of KoreaNuclear Chemistry Research Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero, 989 Beon-gil, Yuseong-gu, Daejeon 34057, Republic of KoreaNuclear Chemistry Research Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero, 989 Beon-gil, Yuseong-gu, Daejeon 34057, Republic of KoreaNuclear Chemistry Research Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero, 989 Beon-gil, Yuseong-gu, Daejeon 34057, Republic of KoreaNuclear Chemistry Research Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero, 989 Beon-gil, Yuseong-gu, Daejeon 34057, Republic of KoreaThis technical note demonstrates the feasibility of using laser ablation inductively coupled plasma mass spectrometry for the characterization of U–7Mo/Al–5Si dispersion fuel. Our measurements show 5.0% Relative Standard Deviation (RSD) for the reproducibility of measured 98Mo/238U ratios in fuel particles from spot analysis, and 3.4% RSD for 98Mo/238U ratios in a NIST-SRM 612 glass standard. Line scanning allows for the distinction of U–7Mo fuel particles from the Al–5Si matrix. Each mass spectrum peak indicates the presence of U–7Mo fuel particles, and the time width of each peak corresponds to the size of that fuel particle. The size of the fuel particles is estimated from the time width of the mass spectrum peak for 98Mo by considering the scan rate used during the line scan. This preliminary application clearly demonstrates that laser ablation inductively coupled plasma mass spectrometry can directly identify isotope ratios and sizes of the fuel particles in U–Mo/Al dispersion fuel. Once optimized further, this instrument will be a powerful tool for investigating irradiated dispersion fuels in terms of fission product distributions in fuel matrices, and the changes in fuel particle size or shape after irradiation.http://www.sciencedirect.com/science/article/pii/S1738573316301607Dispersion FuelInductively Coupled Plasma Mass SpectrometryLaser AblationUranium–Molybdenum Alloy |
spellingShingle | Jeongmook Lee Jai Il Park Young-Sang Youn Yeong-Keong Ha Jong-Yun Kim Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels Nuclear Engineering and Technology Dispersion Fuel Inductively Coupled Plasma Mass Spectrometry Laser Ablation Uranium–Molybdenum Alloy |
title | Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels |
title_full | Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels |
title_fullStr | Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels |
title_full_unstemmed | Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels |
title_short | Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels |
title_sort | application of laser ablation inductively coupled plasma mass spectrometry for characterization of u 7mo al 5si dispersion fuels |
topic | Dispersion Fuel Inductively Coupled Plasma Mass Spectrometry Laser Ablation Uranium–Molybdenum Alloy |
url | http://www.sciencedirect.com/science/article/pii/S1738573316301607 |
work_keys_str_mv | AT jeongmooklee applicationoflaserablationinductivelycoupledplasmamassspectrometryforcharacterizationofu7moal5sidispersionfuels AT jaiilpark applicationoflaserablationinductivelycoupledplasmamassspectrometryforcharacterizationofu7moal5sidispersionfuels AT youngsangyoun applicationoflaserablationinductivelycoupledplasmamassspectrometryforcharacterizationofu7moal5sidispersionfuels AT yeongkeongha applicationoflaserablationinductivelycoupledplasmamassspectrometryforcharacterizationofu7moal5sidispersionfuels AT jongyunkim applicationoflaserablationinductivelycoupledplasmamassspectrometryforcharacterizationofu7moal5sidispersionfuels |