Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations
Tomoki Sakata,1 Corazon De La Pena,2 Suguru Ohira2 1Cardiovascular Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA; 2Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USACorrespondence: Suguru...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2023-03-01
|
Series: | Vascular Health and Risk Management |
Subjects: | |
Online Access: | https://www.dovepress.com/rapid-deployment-aortic-valve-replacement-patient-selection-and-specia-peer-reviewed-fulltext-article-VHRM |
_version_ | 1827976163676389376 |
---|---|
author | Sakata T De La Pena C Ohira S |
author_facet | Sakata T De La Pena C Ohira S |
author_sort | Sakata T |
collection | DOAJ |
description | Tomoki Sakata,1 Corazon De La Pena,2 Suguru Ohira2 1Cardiovascular Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA; 2Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USACorrespondence: Suguru Ohira, Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, 100 Woods Road, Macy Pavilion, Valhalla, NY, 10595, USA, Tel +1 404 234 5433, Email Suguru.Ohira@wmchealth.orgAbstract: Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.Keywords: sutureless valve, rapid deployment valve, aortic valve replacement, minimally invasive cardiac surgery, paravalvular leakage, permanent pacemaker implantation |
first_indexed | 2024-04-09T20:31:00Z |
format | Article |
id | doaj.art-51bfe67e2b2948e598cc82c5274958d6 |
institution | Directory Open Access Journal |
issn | 1178-2048 |
language | English |
last_indexed | 2024-04-09T20:31:00Z |
publishDate | 2023-03-01 |
publisher | Dove Medical Press |
record_format | Article |
series | Vascular Health and Risk Management |
spelling | doaj.art-51bfe67e2b2948e598cc82c5274958d62023-03-30T18:13:14ZengDove Medical PressVascular Health and Risk Management1178-20482023-03-01Volume 1916918082634Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special ConsiderationsSakata TDe La Pena COhira STomoki Sakata,1 Corazon De La Pena,2 Suguru Ohira2 1Cardiovascular Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA; 2Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USACorrespondence: Suguru Ohira, Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, 100 Woods Road, Macy Pavilion, Valhalla, NY, 10595, USA, Tel +1 404 234 5433, Email Suguru.Ohira@wmchealth.orgAbstract: Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.Keywords: sutureless valve, rapid deployment valve, aortic valve replacement, minimally invasive cardiac surgery, paravalvular leakage, permanent pacemaker implantationhttps://www.dovepress.com/rapid-deployment-aortic-valve-replacement-patient-selection-and-specia-peer-reviewed-fulltext-article-VHRMsutureless valverapid deployment valveaortic valve replacementminimally invasive cardiac surgeryparavalvular leakagepermanent pacemaker implantation |
spellingShingle | Sakata T De La Pena C Ohira S Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations Vascular Health and Risk Management sutureless valve rapid deployment valve aortic valve replacement minimally invasive cardiac surgery paravalvular leakage permanent pacemaker implantation |
title | Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations |
title_full | Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations |
title_fullStr | Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations |
title_full_unstemmed | Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations |
title_short | Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations |
title_sort | rapid deployment aortic valve replacement patient selection and special considerations |
topic | sutureless valve rapid deployment valve aortic valve replacement minimally invasive cardiac surgery paravalvular leakage permanent pacemaker implantation |
url | https://www.dovepress.com/rapid-deployment-aortic-valve-replacement-patient-selection-and-specia-peer-reviewed-fulltext-article-VHRM |
work_keys_str_mv | AT sakatat rapiddeploymentaorticvalvereplacementpatientselectionandspecialconsiderations AT delapenac rapiddeploymentaorticvalvereplacementpatientselectionandspecialconsiderations AT ohiras rapiddeploymentaorticvalvereplacementpatientselectionandspecialconsiderations |