Investigation of the Flow-Induced Noise and Optimization Design of a Short Tube Throttle Valve

Compared with the globe valves and other on-off valves, cavitation and noise are more severe in the throttle control valve of the refrigerating system due to the higher saturated vapor pressure of the refrigerant. A short tube throttle valve (STTV) is an important throttle control component and cavi...

Full description

Bibliographic Details
Main Authors: K. P. Zhang, D.-Z. Wu, J. Y. Wang, Y. X. Song, Z. B. Feng, Y. C. He, L. H. Xuan
Format: Article
Language:English
Published: Isfahan University of Technology 2024-01-01
Series:Journal of Applied Fluid Mechanics
Subjects:
Online Access:https://www.jafmonline.net/article_2395_4a5a3d3124e2f40237d71225ab88a502.pdf