Update of specific electric loads of public premises located in residential buildings

THE PURPOSE. To determine the composition of electricity consumers in apartment buildings. To analyze the power consumption of organizations located on the first two floors of apartment buildings. To justify the need to update the standards for electrical loads for public premises built into residen...

Full description

Bibliographic Details
Main Authors: Yu. I. Soluyanov, A. R. Akhmetshin, V. I. Soluyanov
Format: Article
Language:English
Published: Kazan State Power Engineering University 2021-07-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1842
_version_ 1797762188349276160
author Yu. I. Soluyanov
A. R. Akhmetshin
V. I. Soluyanov
author_facet Yu. I. Soluyanov
A. R. Akhmetshin
V. I. Soluyanov
author_sort Yu. I. Soluyanov
collection DOAJ
description THE PURPOSE. To determine the composition of electricity consumers in apartment buildings. To analyze the power consumption of organizations located on the first two floors of apartment buildings. To justify the need to update the standards for electrical loads for public premises built into residential buildings. METHODS. Information on electricity consumption was received by automated electricity metering system from smart meters installed directly at consumers. To achieve this goal, statistical methods for analyzing energy consumption were used. RESULTS. The article describes the relevance of the topic, provides a rationale for adjusting the normative values of specific electrical loads for public premises built into residential buildings. The percentage of consumer groups is shown on the example of several apartment buildings. The annual specific average monthly graphs of electricity consumption are presented: shops, offices, pharmacies, restaurants. CONCLUSION. In an effort to increase the level of comfort, developers are interested in developing the infrastructure of the facilities, mainly for this, they use ground and first floors, in which retail and office areas are most often located. Research by the Roselectromontazh Association has shown that to determine the electrical load of non-residential commercial premises, one has to use one averaged value due to the constant change in the purpose of premises and the complexity of determining the occupied area.
first_indexed 2024-03-12T19:24:41Z
format Article
id doaj.art-520b7503759242bab13f4ce750489ec8
institution Directory Open Access Journal
issn 1998-9903
language English
last_indexed 2024-03-12T19:24:41Z
publishDate 2021-07-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj.art-520b7503759242bab13f4ce750489ec82023-08-02T04:57:37ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032021-07-01233475710.30724/1998-9903-2021-23-3-47-57759Update of specific electric loads of public premises located in residential buildingsYu. I. Soluyanov0A. R. Akhmetshin1V. I. Soluyanov2Kazan State Power Engineering University; Association «Roselectromontazh»; JSC «Tatelektromontazh»Kazan State Power Engineering University; Association «Roselectromontazh»Kazan State Power Engineering University; JSC «Tatelektromontazh»THE PURPOSE. To determine the composition of electricity consumers in apartment buildings. To analyze the power consumption of organizations located on the first two floors of apartment buildings. To justify the need to update the standards for electrical loads for public premises built into residential buildings. METHODS. Information on electricity consumption was received by automated electricity metering system from smart meters installed directly at consumers. To achieve this goal, statistical methods for analyzing energy consumption were used. RESULTS. The article describes the relevance of the topic, provides a rationale for adjusting the normative values of specific electrical loads for public premises built into residential buildings. The percentage of consumer groups is shown on the example of several apartment buildings. The annual specific average monthly graphs of electricity consumption are presented: shops, offices, pharmacies, restaurants. CONCLUSION. In an effort to increase the level of comfort, developers are interested in developing the infrastructure of the facilities, mainly for this, they use ground and first floors, in which retail and office areas are most often located. Research by the Roselectromontazh Association has shown that to determine the electrical load of non-residential commercial premises, one has to use one averaged value due to the constant change in the purpose of premises and the complexity of determining the occupied area.https://www.energyret.ru/jour/article/view/1842specific design electrical loadspower consumption of public premises built into residential buildingslocked electrical powerreserve electrical powerdesign of residential complexe
spellingShingle Yu. I. Soluyanov
A. R. Akhmetshin
V. I. Soluyanov
Update of specific electric loads of public premises located in residential buildings
Известия высших учебных заведений: Проблемы энергетики
specific design electrical loads
power consumption of public premises built into residential buildings
locked electrical power
reserve electrical power
design of residential complexe
title Update of specific electric loads of public premises located in residential buildings
title_full Update of specific electric loads of public premises located in residential buildings
title_fullStr Update of specific electric loads of public premises located in residential buildings
title_full_unstemmed Update of specific electric loads of public premises located in residential buildings
title_short Update of specific electric loads of public premises located in residential buildings
title_sort update of specific electric loads of public premises located in residential buildings
topic specific design electrical loads
power consumption of public premises built into residential buildings
locked electrical power
reserve electrical power
design of residential complexe
url https://www.energyret.ru/jour/article/view/1842
work_keys_str_mv AT yuisoluyanov updateofspecificelectricloadsofpublicpremiseslocatedinresidentialbuildings
AT arakhmetshin updateofspecificelectricloadsofpublicpremiseslocatedinresidentialbuildings
AT visoluyanov updateofspecificelectricloadsofpublicpremiseslocatedinresidentialbuildings