Update of specific electric loads of public premises located in residential buildings
THE PURPOSE. To determine the composition of electricity consumers in apartment buildings. To analyze the power consumption of organizations located on the first two floors of apartment buildings. To justify the need to update the standards for electrical loads for public premises built into residen...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kazan State Power Engineering University
2021-07-01
|
Series: | Известия высших учебных заведений: Проблемы энергетики |
Subjects: | |
Online Access: | https://www.energyret.ru/jour/article/view/1842 |
_version_ | 1797762188349276160 |
---|---|
author | Yu. I. Soluyanov A. R. Akhmetshin V. I. Soluyanov |
author_facet | Yu. I. Soluyanov A. R. Akhmetshin V. I. Soluyanov |
author_sort | Yu. I. Soluyanov |
collection | DOAJ |
description | THE PURPOSE. To determine the composition of electricity consumers in apartment buildings. To analyze the power consumption of organizations located on the first two floors of apartment buildings. To justify the need to update the standards for electrical loads for public premises built into residential buildings. METHODS. Information on electricity consumption was received by automated electricity metering system from smart meters installed directly at consumers. To achieve this goal, statistical methods for analyzing energy consumption were used. RESULTS. The article describes the relevance of the topic, provides a rationale for adjusting the normative values of specific electrical loads for public premises built into residential buildings. The percentage of consumer groups is shown on the example of several apartment buildings. The annual specific average monthly graphs of electricity consumption are presented: shops, offices, pharmacies, restaurants. CONCLUSION. In an effort to increase the level of comfort, developers are interested in developing the infrastructure of the facilities, mainly for this, they use ground and first floors, in which retail and office areas are most often located. Research by the Roselectromontazh Association has shown that to determine the electrical load of non-residential commercial premises, one has to use one averaged value due to the constant change in the purpose of premises and the complexity of determining the occupied area. |
first_indexed | 2024-03-12T19:24:41Z |
format | Article |
id | doaj.art-520b7503759242bab13f4ce750489ec8 |
institution | Directory Open Access Journal |
issn | 1998-9903 |
language | English |
last_indexed | 2024-03-12T19:24:41Z |
publishDate | 2021-07-01 |
publisher | Kazan State Power Engineering University |
record_format | Article |
series | Известия высших учебных заведений: Проблемы энергетики |
spelling | doaj.art-520b7503759242bab13f4ce750489ec82023-08-02T04:57:37ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032021-07-01233475710.30724/1998-9903-2021-23-3-47-57759Update of specific electric loads of public premises located in residential buildingsYu. I. Soluyanov0A. R. Akhmetshin1V. I. Soluyanov2Kazan State Power Engineering University; Association «Roselectromontazh»; JSC «Tatelektromontazh»Kazan State Power Engineering University; Association «Roselectromontazh»Kazan State Power Engineering University; JSC «Tatelektromontazh»THE PURPOSE. To determine the composition of electricity consumers in apartment buildings. To analyze the power consumption of organizations located on the first two floors of apartment buildings. To justify the need to update the standards for electrical loads for public premises built into residential buildings. METHODS. Information on electricity consumption was received by automated electricity metering system from smart meters installed directly at consumers. To achieve this goal, statistical methods for analyzing energy consumption were used. RESULTS. The article describes the relevance of the topic, provides a rationale for adjusting the normative values of specific electrical loads for public premises built into residential buildings. The percentage of consumer groups is shown on the example of several apartment buildings. The annual specific average monthly graphs of electricity consumption are presented: shops, offices, pharmacies, restaurants. CONCLUSION. In an effort to increase the level of comfort, developers are interested in developing the infrastructure of the facilities, mainly for this, they use ground and first floors, in which retail and office areas are most often located. Research by the Roselectromontazh Association has shown that to determine the electrical load of non-residential commercial premises, one has to use one averaged value due to the constant change in the purpose of premises and the complexity of determining the occupied area.https://www.energyret.ru/jour/article/view/1842specific design electrical loadspower consumption of public premises built into residential buildingslocked electrical powerreserve electrical powerdesign of residential complexe |
spellingShingle | Yu. I. Soluyanov A. R. Akhmetshin V. I. Soluyanov Update of specific electric loads of public premises located in residential buildings Известия высших учебных заведений: Проблемы энергетики specific design electrical loads power consumption of public premises built into residential buildings locked electrical power reserve electrical power design of residential complexe |
title | Update of specific electric loads of public premises located in residential buildings |
title_full | Update of specific electric loads of public premises located in residential buildings |
title_fullStr | Update of specific electric loads of public premises located in residential buildings |
title_full_unstemmed | Update of specific electric loads of public premises located in residential buildings |
title_short | Update of specific electric loads of public premises located in residential buildings |
title_sort | update of specific electric loads of public premises located in residential buildings |
topic | specific design electrical loads power consumption of public premises built into residential buildings locked electrical power reserve electrical power design of residential complexe |
url | https://www.energyret.ru/jour/article/view/1842 |
work_keys_str_mv | AT yuisoluyanov updateofspecificelectricloadsofpublicpremiseslocatedinresidentialbuildings AT arakhmetshin updateofspecificelectricloadsofpublicpremiseslocatedinresidentialbuildings AT visoluyanov updateofspecificelectricloadsofpublicpremiseslocatedinresidentialbuildings |