Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears

With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from th...

Full description

Bibliographic Details
Main Authors: Guoming Wang, Gyung-Suk Kil, Hong-Keun Ji, Jong-Hyuk Lee
Format: Article
Language:English
Published: MDPI AG 2017-11-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/10/11/1762
_version_ 1798041656323211264
author Guoming Wang
Gyung-Suk Kil
Hong-Keun Ji
Jong-Hyuk Lee
author_facet Guoming Wang
Gyung-Suk Kil
Hong-Keun Ji
Jong-Hyuk Lee
author_sort Guoming Wang
collection DOAJ
description With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD) signal generated in GIS spacers based on discrete wavelet transform (WT). Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded, whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components.
first_indexed 2024-04-11T22:24:34Z
format Article
id doaj.art-522c701860364c4487418041ad6ce00a
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-11T22:24:34Z
publishDate 2017-11-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-522c701860364c4487418041ad6ce00a2022-12-22T03:59:52ZengMDPI AGEnergies1996-10732017-11-011011176210.3390/en10111762en10111762Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated SwitchgearsGuoming Wang0Gyung-Suk Kil1Hong-Keun Ji2Jong-Hyuk Lee3Department of Electrical and Electronics Engineering, Korea Maritime and Ocean University, Busan 49112, KoreaDepartment of Electrical and Electronics Engineering, Korea Maritime and Ocean University, Busan 49112, KoreaForensic Safety Section, National Forensic Service Busan Institute, Yangsan 50612, KoreaHVDC Production Team, LSIS Co., Ltd., Busan 46739, KoreaWith the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD) signal generated in GIS spacers based on discrete wavelet transform (WT). Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded, whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components.https://www.mdpi.com/1996-1073/10/11/1762partial discharge (PD)gas-insulated switchgears (GISs)spacercapacitive componentwavelet transform (WT)multi-resolution analysis (MRA)
spellingShingle Guoming Wang
Gyung-Suk Kil
Hong-Keun Ji
Jong-Hyuk Lee
Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
Energies
partial discharge (PD)
gas-insulated switchgears (GISs)
spacer
capacitive component
wavelet transform (WT)
multi-resolution analysis (MRA)
title Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
title_full Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
title_fullStr Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
title_full_unstemmed Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
title_short Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
title_sort disturbance elimination for partial discharge detection in the spacer of gas insulated switchgears
topic partial discharge (PD)
gas-insulated switchgears (GISs)
spacer
capacitive component
wavelet transform (WT)
multi-resolution analysis (MRA)
url https://www.mdpi.com/1996-1073/10/11/1762
work_keys_str_mv AT guomingwang disturbanceeliminationforpartialdischargedetectioninthespacerofgasinsulatedswitchgears
AT gyungsukkil disturbanceeliminationforpartialdischargedetectioninthespacerofgasinsulatedswitchgears
AT hongkeunji disturbanceeliminationforpartialdischargedetectioninthespacerofgasinsulatedswitchgears
AT jonghyuklee disturbanceeliminationforpartialdischargedetectioninthespacerofgasinsulatedswitchgears