Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies.
PURPOSE:To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. METHODS:In UK Biobank, OCT images were acquired between 2...
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2016-01-01
|
Series: | PLoS ONE |
Online Access: | http://europepmc.org/articles/PMC5055325?pdf=render |
_version_ | 1828471993536610304 |
---|---|
author | Pearse A Keane Carlota M Grossi Paul J Foster Qi Yang Charles A Reisman Kinpui Chan Tunde Peto Dhanes Thomas Praveen J Patel UK Biobank Eye Vision Consortium |
author_facet | Pearse A Keane Carlota M Grossi Paul J Foster Qi Yang Charles A Reisman Kinpui Chan Tunde Peto Dhanes Thomas Praveen J Patel UK Biobank Eye Vision Consortium |
author_sort | Pearse A Keane |
collection | DOAJ |
description | PURPOSE:To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. METHODS:In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available "spectral domain" OCT device (3D OCT-1000, Topcon). Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL). This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion. RESULTS:67,321 participants (134,642 eyes) in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days. CONCLUSIONS:We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging. |
first_indexed | 2024-12-11T05:21:15Z |
format | Article |
id | doaj.art-525066dc56b04e118d020f08b9b35d89 |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-12-11T05:21:15Z |
publishDate | 2016-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-525066dc56b04e118d020f08b9b35d892022-12-22T01:19:41ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-011110e016409510.1371/journal.pone.0164095Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies.Pearse A KeaneCarlota M GrossiPaul J FosterQi YangCharles A ReismanKinpui ChanTunde PetoDhanes ThomasPraveen J PatelUK Biobank Eye Vision ConsortiumPURPOSE:To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. METHODS:In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available "spectral domain" OCT device (3D OCT-1000, Topcon). Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL). This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion. RESULTS:67,321 participants (134,642 eyes) in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days. CONCLUSIONS:We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging.http://europepmc.org/articles/PMC5055325?pdf=render |
spellingShingle | Pearse A Keane Carlota M Grossi Paul J Foster Qi Yang Charles A Reisman Kinpui Chan Tunde Peto Dhanes Thomas Praveen J Patel UK Biobank Eye Vision Consortium Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies. PLoS ONE |
title | Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies. |
title_full | Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies. |
title_fullStr | Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies. |
title_full_unstemmed | Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies. |
title_short | Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies. |
title_sort | optical coherence tomography in the uk biobank study rapid automated analysis of retinal thickness for large population based studies |
url | http://europepmc.org/articles/PMC5055325?pdf=render |
work_keys_str_mv | AT pearseakeane opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT carlotamgrossi opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT pauljfoster opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT qiyang opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT charlesareisman opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT kinpuichan opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT tundepeto opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT dhanesthomas opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT praveenjpatel opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies AT ukbiobankeyevisionconsortium opticalcoherencetomographyintheukbiobankstudyrapidautomatedanalysisofretinalthicknessforlargepopulationbasedstudies |