Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?

Category: Ankle Arthritis Introduction/Purpose: The unique anatomy and biomechanics of the ankle joint have made total ankle arthroplasty (TAA) challenging over the past few decades. Final implant position and successful soft tissue balancing are key components to the longevity of total ankle implan...

Full description

Bibliographic Details
Main Authors: Mario Escudero MD, Kevin Wing MD, FRCSC, Feras Waly MD, Thomas Bemenderfer MD, MBA, W. Hodges Davis MD, Robert Anderson MD, Murray Penner MD, FRCSC
Format: Article
Language:English
Published: SAGE Publishing 2018-09-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011418S00046
_version_ 1818210474637918208
author Mario Escudero MD
Kevin Wing MD, FRCSC
Feras Waly MD
Thomas Bemenderfer MD, MBA
W. Hodges Davis MD
Robert Anderson MD
Murray Penner MD, FRCSC
author_facet Mario Escudero MD
Kevin Wing MD, FRCSC
Feras Waly MD
Thomas Bemenderfer MD, MBA
W. Hodges Davis MD
Robert Anderson MD
Murray Penner MD, FRCSC
author_sort Mario Escudero MD
collection DOAJ
description Category: Ankle Arthritis Introduction/Purpose: The unique anatomy and biomechanics of the ankle joint have made total ankle arthroplasty (TAA) challenging over the past few decades. Final implant position and successful soft tissue balancing are key components to the longevity of total ankle implants. Preoperative computer navigation, templating, and patient-specific instrumentation (PSI) have shown promising results in total ankle replacement with accurate and reproducible radiographic outcomes. Recent data has also suggested that even experienced surgeons benefit from the improved time efficiency of PSI. The purpose of this study is to determine if radiographic outcomes differ between patients undergoing TAA with PSI and those who undergo TAA with standard instrumentation (SI). Methods: The first 67 consecutive patients who underwent primary Infinity total ankle arthroplasty (TAA) at 2 North American sites between 2013 and 2015 were reviewed in a prospective observational study. All TAA’s were performed by one of four fellowship-trained foot and ankle surgeons. Demographic, radiographic, and functional outcome data was collected preoperatively, at 6-12 months postoperatively, and annually thereafter. The radiographic variables measured were the medial distal tibial angle (MDTA), talar tilt angle (TTA), lateral talar station (LTS), sagittal distal tibial articular angle (sDTAA), and the gamma angle. Acceptable intervals for each parameter were selected and TAAs were then categorized as being “correctly aligned” or “not correctly aligned” for all the parameters described. The rate of “correctly aligned” TAA’s was compared between cases with PSI and those with SI. Fisher’s exact test was used to analyze difference by groups. A significance of 5% was used. Results: Of a total of 67 TAAs included, 51 were in the PSI group and 16 in the SI group. No significant statistically differences were found between PSI and NPSI regarding MDTA (p=0.174), LTS (p=0.922), sDTAA (p=0.986), gamma angle (p=0.252) and TTA (p=0.145). We did not find a significant statistical difference in the rate of “correctly aligned TAR” when we compared both groups (p=0.35). Conclusion: This study suggests that both PSI and SI provide accurate and reproducible TAA radiographic alignment when performed by experienced surgeons. In view of previously published data demonstrating high levels of reproducibility for PSI in TAA, these data also suggest that PSI may offer a means for less experienced surgeons to achieve radiographic results similar to those achieved by experienced surgeons. It also suggests that experienced surgeons may not need to use PSI to achieve satisfactory implant alignment, though improved time efficiency with PSI, as demonstrated in other studies, may still be of benefit for experienced surgeons.
first_indexed 2024-12-12T05:17:11Z
format Article
id doaj.art-528fae4f5a024dba923aa1445a3e66cb
institution Directory Open Access Journal
issn 2473-0114
language English
last_indexed 2024-12-12T05:17:11Z
publishDate 2018-09-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj.art-528fae4f5a024dba923aa1445a3e66cb2022-12-22T00:36:44ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142018-09-01310.1177/2473011418S00046Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?Mario Escudero MDKevin Wing MD, FRCSCFeras Waly MDThomas Bemenderfer MD, MBAW. Hodges Davis MDRobert Anderson MDMurray Penner MD, FRCSCCategory: Ankle Arthritis Introduction/Purpose: The unique anatomy and biomechanics of the ankle joint have made total ankle arthroplasty (TAA) challenging over the past few decades. Final implant position and successful soft tissue balancing are key components to the longevity of total ankle implants. Preoperative computer navigation, templating, and patient-specific instrumentation (PSI) have shown promising results in total ankle replacement with accurate and reproducible radiographic outcomes. Recent data has also suggested that even experienced surgeons benefit from the improved time efficiency of PSI. The purpose of this study is to determine if radiographic outcomes differ between patients undergoing TAA with PSI and those who undergo TAA with standard instrumentation (SI). Methods: The first 67 consecutive patients who underwent primary Infinity total ankle arthroplasty (TAA) at 2 North American sites between 2013 and 2015 were reviewed in a prospective observational study. All TAA’s were performed by one of four fellowship-trained foot and ankle surgeons. Demographic, radiographic, and functional outcome data was collected preoperatively, at 6-12 months postoperatively, and annually thereafter. The radiographic variables measured were the medial distal tibial angle (MDTA), talar tilt angle (TTA), lateral talar station (LTS), sagittal distal tibial articular angle (sDTAA), and the gamma angle. Acceptable intervals for each parameter were selected and TAAs were then categorized as being “correctly aligned” or “not correctly aligned” for all the parameters described. The rate of “correctly aligned” TAA’s was compared between cases with PSI and those with SI. Fisher’s exact test was used to analyze difference by groups. A significance of 5% was used. Results: Of a total of 67 TAAs included, 51 were in the PSI group and 16 in the SI group. No significant statistically differences were found between PSI and NPSI regarding MDTA (p=0.174), LTS (p=0.922), sDTAA (p=0.986), gamma angle (p=0.252) and TTA (p=0.145). We did not find a significant statistical difference in the rate of “correctly aligned TAR” when we compared both groups (p=0.35). Conclusion: This study suggests that both PSI and SI provide accurate and reproducible TAA radiographic alignment when performed by experienced surgeons. In view of previously published data demonstrating high levels of reproducibility for PSI in TAA, these data also suggest that PSI may offer a means for less experienced surgeons to achieve radiographic results similar to those achieved by experienced surgeons. It also suggests that experienced surgeons may not need to use PSI to achieve satisfactory implant alignment, though improved time efficiency with PSI, as demonstrated in other studies, may still be of benefit for experienced surgeons.https://doi.org/10.1177/2473011418S00046
spellingShingle Mario Escudero MD
Kevin Wing MD, FRCSC
Feras Waly MD
Thomas Bemenderfer MD, MBA
W. Hodges Davis MD
Robert Anderson MD
Murray Penner MD, FRCSC
Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?
Foot & Ankle Orthopaedics
title Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?
title_full Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?
title_fullStr Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?
title_full_unstemmed Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?
title_short Does Patient-specific Instrumentation Yield Better Component Position than Standard Instrumentation in Total Ankle Arthroplasty?
title_sort does patient specific instrumentation yield better component position than standard instrumentation in total ankle arthroplasty
url https://doi.org/10.1177/2473011418S00046
work_keys_str_mv AT marioescuderomd doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty
AT kevinwingmdfrcsc doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty
AT feraswalymd doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty
AT thomasbemenderfermdmba doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty
AT whodgesdavismd doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty
AT robertandersonmd doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty
AT murraypennermdfrcsc doespatientspecificinstrumentationyieldbettercomponentpositionthanstandardinstrumentationintotalanklearthroplasty