Ecological assessment of noise impact of dry transformer substations on the environment

At present, special attention is paid to assessing the negative impact of power facilities on the environment, including the impact of noise generated by power equipment. Power transformers are one of the sources of noise for industrial areas and the surrounding area. The noise of transformers is ca...

সম্পূর্ণ বিবরণ

গ্রন্থ-পঞ্জীর বিবরন
প্রধান লেখক: Barseghyan Sarkis, Hayrapetyan Arman, Kirakosyan Armen
বিন্যাস: প্রবন্ধ
ভাষা:English
প্রকাশিত: EDP Sciences 2021-01-01
মালা:E3S Web of Conferences
অনলাইন ব্যবহার করুন:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/41/e3sconf_apeem2021_02011.pdf
_version_ 1830478532297359360
author Barseghyan Sarkis
Hayrapetyan Arman
Kirakosyan Armen
author_facet Barseghyan Sarkis
Hayrapetyan Arman
Kirakosyan Armen
author_sort Barseghyan Sarkis
collection DOAJ
description At present, special attention is paid to assessing the negative impact of power facilities on the environment, including the impact of noise generated by power equipment. Power transformers are one of the sources of noise for industrial areas and the surrounding area. The noise of transformers is caused both by the vibration of its active part and by the fans of the cooling system, which is amplified by resonance phenomena in its individual elements. The presented work provides an environmental assessment of the noise impact of transformer substations. The noise impact of a transformer substation is considered on the example of three dry transformers in the area immediately adjacent to the living space. A new corrected approach was developed and tested for calculating the sound power level for dry transformers with the MatLab software package. An assessment of the noise impact of the projected transformer substation to install three dry transformers was the voltage class of which is 400 kVA, and one has 1000 kVA for the territory immediately adjacent to the living area was made. In our researches, the regulated noise characteristic for transformers is the corrected sound power level, which is indicated in the technical characteristics of the transformer. Calculations on non-standard nominal rated powers were carried out.
first_indexed 2024-12-21T16:30:43Z
format Article
id doaj.art-52acec36268b4b1f824425f00afc767c
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-12-21T16:30:43Z
publishDate 2021-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-52acec36268b4b1f824425f00afc767c2022-12-21T18:57:21ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012650201110.1051/e3sconf/202126502011e3sconf_apeem2021_02011Ecological assessment of noise impact of dry transformer substations on the environmentBarseghyan SarkisHayrapetyan ArmanKirakosyan ArmenAt present, special attention is paid to assessing the negative impact of power facilities on the environment, including the impact of noise generated by power equipment. Power transformers are one of the sources of noise for industrial areas and the surrounding area. The noise of transformers is caused both by the vibration of its active part and by the fans of the cooling system, which is amplified by resonance phenomena in its individual elements. The presented work provides an environmental assessment of the noise impact of transformer substations. The noise impact of a transformer substation is considered on the example of three dry transformers in the area immediately adjacent to the living space. A new corrected approach was developed and tested for calculating the sound power level for dry transformers with the MatLab software package. An assessment of the noise impact of the projected transformer substation to install three dry transformers was the voltage class of which is 400 kVA, and one has 1000 kVA for the territory immediately adjacent to the living area was made. In our researches, the regulated noise characteristic for transformers is the corrected sound power level, which is indicated in the technical characteristics of the transformer. Calculations on non-standard nominal rated powers were carried out.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/41/e3sconf_apeem2021_02011.pdf
spellingShingle Barseghyan Sarkis
Hayrapetyan Arman
Kirakosyan Armen
Ecological assessment of noise impact of dry transformer substations on the environment
E3S Web of Conferences
title Ecological assessment of noise impact of dry transformer substations on the environment
title_full Ecological assessment of noise impact of dry transformer substations on the environment
title_fullStr Ecological assessment of noise impact of dry transformer substations on the environment
title_full_unstemmed Ecological assessment of noise impact of dry transformer substations on the environment
title_short Ecological assessment of noise impact of dry transformer substations on the environment
title_sort ecological assessment of noise impact of dry transformer substations on the environment
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/41/e3sconf_apeem2021_02011.pdf
work_keys_str_mv AT barseghyansarkis ecologicalassessmentofnoiseimpactofdrytransformersubstationsontheenvironment
AT hayrapetyanarman ecologicalassessmentofnoiseimpactofdrytransformersubstationsontheenvironment
AT kirakosyanarmen ecologicalassessmentofnoiseimpactofdrytransformersubstationsontheenvironment