15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation

Pulmonary vein ablation (PVA) has been used to treat persistent supraventricular arrhythmias, in which a cardiologist first isolates and then thermally ablates the source of the arrhythmia1. Since the esophagus is in close proximity to the left atrium, heat induced injury to the esophagus may occur2...

Full description

Bibliographic Details
Main Authors: Mohamed Elhakim, Paul Loubser, Bharat Kantharia, Nada B. Memon
Format: Article
Language:English
Published: Saudi Heart Association 2015-10-01
Series:Journal of the Saudi Heart Association
Online Access:http://www.sciencedirect.com/science/article/pii/S1016731515002559
_version_ 1819229186981625856
author Mohamed Elhakim
Paul Loubser
Bharat Kantharia
Nada B. Memon
author_facet Mohamed Elhakim
Paul Loubser
Bharat Kantharia
Nada B. Memon
author_sort Mohamed Elhakim
collection DOAJ
description Pulmonary vein ablation (PVA) has been used to treat persistent supraventricular arrhythmias, in which a cardiologist first isolates and then thermally ablates the source of the arrhythmia1. Since the esophagus is in close proximity to the left atrium, heat induced injury to the esophagus may occur2. Although the incidence is low, the mortality rate is high. Luminal esophageal temperature (ET) monitoring is one of the most effective measures to minimize the risk of injury3. In this retrospective study, we elected to analyze temperature changes during PVA at two different temperature monitoring sites in the esophagus. Methods: The anesthetic technique was standardized and utilized general anesthesia, endotracheal intubation and an arterial line. ET monitors were placed at two mid-atrial locations, ET1 and ET2 separated by 1–1.5 inches in the esophagus, as determined by cardiologist using fluoroscopy. Temperatures at both ET1 and ET2 locations were recorded simultaneously when radio-frequency ablation was performed at different left atrial sites. The peak ET was recorded at each location. In particular, the increase over baseline ET and the difference between ET1 and ET2, were noted. Results: Twenty five patients were studied. Ablation sites in the left atrium included the anterior, posterior, inferior regions and the pulmonary veins. The most significant increases in temperature were seen during ablation of the posterior left atrium ranging from 0.1 to 4.0 degrees. However, in 20 out of 25 patients, measurements of ET1 ≠ ET2. The absolute value of difference of temperature between ET1 and ET2 ranged from 0.4 to 3.8, with a mean of 1.3 and a standard deviation of 1.1. Discussion: These findings suggest that measurement of temperature at two separate esophageal locations is more sensitive that one location in detecting temperature increases during PVA. The ablating electrode during PVA moves from different areas within the left atrium, and therefore, a wide area of temperature measurement is needed for more accurate monitoring. Furthermore, the most significant increases in temperature occurred when ablation performed in the posterior left atrium, adjacent to the esophagus. The implications of these observations suggest that one location of temperature measurement may not be accurate enough in detecting a “true” esophageal temperature. Further studies are needed to verify these findings in a prospective study and to ascertain whether this has any patient safety ramifications for preventing esophageal injury.
first_indexed 2024-12-23T11:09:11Z
format Article
id doaj.art-532b99fccc4b4dd8ac34ba9029fe7ca5
institution Directory Open Access Journal
issn 1016-7315
language English
last_indexed 2024-12-23T11:09:11Z
publishDate 2015-10-01
publisher Saudi Heart Association
record_format Article
series Journal of the Saudi Heart Association
spelling doaj.art-532b99fccc4b4dd8ac34ba9029fe7ca52022-12-21T17:49:23ZengSaudi Heart AssociationJournal of the Saudi Heart Association1016-73152015-10-0127430510.1016/j.jsha.2015.05.19615. Measurement of esophageal temperature at two separate sites during pulmonary vein ablationMohamed ElhakimPaul LoubserBharat KanthariaNada B. MemonPulmonary vein ablation (PVA) has been used to treat persistent supraventricular arrhythmias, in which a cardiologist first isolates and then thermally ablates the source of the arrhythmia1. Since the esophagus is in close proximity to the left atrium, heat induced injury to the esophagus may occur2. Although the incidence is low, the mortality rate is high. Luminal esophageal temperature (ET) monitoring is one of the most effective measures to minimize the risk of injury3. In this retrospective study, we elected to analyze temperature changes during PVA at two different temperature monitoring sites in the esophagus. Methods: The anesthetic technique was standardized and utilized general anesthesia, endotracheal intubation and an arterial line. ET monitors were placed at two mid-atrial locations, ET1 and ET2 separated by 1–1.5 inches in the esophagus, as determined by cardiologist using fluoroscopy. Temperatures at both ET1 and ET2 locations were recorded simultaneously when radio-frequency ablation was performed at different left atrial sites. The peak ET was recorded at each location. In particular, the increase over baseline ET and the difference between ET1 and ET2, were noted. Results: Twenty five patients were studied. Ablation sites in the left atrium included the anterior, posterior, inferior regions and the pulmonary veins. The most significant increases in temperature were seen during ablation of the posterior left atrium ranging from 0.1 to 4.0 degrees. However, in 20 out of 25 patients, measurements of ET1 ≠ ET2. The absolute value of difference of temperature between ET1 and ET2 ranged from 0.4 to 3.8, with a mean of 1.3 and a standard deviation of 1.1. Discussion: These findings suggest that measurement of temperature at two separate esophageal locations is more sensitive that one location in detecting temperature increases during PVA. The ablating electrode during PVA moves from different areas within the left atrium, and therefore, a wide area of temperature measurement is needed for more accurate monitoring. Furthermore, the most significant increases in temperature occurred when ablation performed in the posterior left atrium, adjacent to the esophagus. The implications of these observations suggest that one location of temperature measurement may not be accurate enough in detecting a “true” esophageal temperature. Further studies are needed to verify these findings in a prospective study and to ascertain whether this has any patient safety ramifications for preventing esophageal injury.http://www.sciencedirect.com/science/article/pii/S1016731515002559
spellingShingle Mohamed Elhakim
Paul Loubser
Bharat Kantharia
Nada B. Memon
15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation
Journal of the Saudi Heart Association
title 15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation
title_full 15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation
title_fullStr 15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation
title_full_unstemmed 15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation
title_short 15. Measurement of esophageal temperature at two separate sites during pulmonary vein ablation
title_sort 15 measurement of esophageal temperature at two separate sites during pulmonary vein ablation
url http://www.sciencedirect.com/science/article/pii/S1016731515002559
work_keys_str_mv AT mohamedelhakim 15measurementofesophagealtemperatureattwoseparatesitesduringpulmonaryveinablation
AT paulloubser 15measurementofesophagealtemperatureattwoseparatesitesduringpulmonaryveinablation
AT bharatkantharia 15measurementofesophagealtemperatureattwoseparatesitesduringpulmonaryveinablation
AT nadabmemon 15measurementofesophagealtemperatureattwoseparatesitesduringpulmonaryveinablation