An expeditious and precise method for diameter reduction of venous aneurysm causing arteriovenous fistula steal syndrome
Clinically significant dialysis access steal syndrome occurs in 1% to 8% of patients. In the present report, we describe an innovative, hybrid option for venoplasty of a cephalic vein aneurysm using a vascular staple device in conjunction with a 6-mm, endovascular balloon placed a few centimeters di...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-06-01
|
Series: | Journal of Vascular Surgery Cases and Innovative Techniques |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2468428723000783 |