Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna

When the metal structures distributed in the underground roadway are in the near-field of the large loop transmitting antenna, they will couple the electromagnetic wave energy of the large loop transmitting antenna. Once the metal structure has a breakpoint and friction occurs, it may produce fricti...

Full description

Bibliographic Details
Main Authors: FAN Sihan, YANG Wei, LIU Junbo
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2022-06-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2022030093
_version_ 1797868983493328896
author FAN Sihan
YANG Wei
LIU Junbo
author_facet FAN Sihan
YANG Wei
LIU Junbo
author_sort FAN Sihan
collection DOAJ
description When the metal structures distributed in the underground roadway are in the near-field of the large loop transmitting antenna, they will couple the electromagnetic wave energy of the large loop transmitting antenna. Once the metal structure has a breakpoint and friction occurs, it may produce friction discharge spark and ignite gas. This poses a threat to the safety of coal mine. In order to solve this problem, the safety of electromagnetic wave energy of underground metal structure near-field coupled large loop transmitting antenna is analyzed from two aspects of near-field coupling risk coefficient and safe distance. By establishing the equivalent circuit of electromagnetic wave energy of metal structure near-field coupled large loop transmitting antenna, the expressions of near-field coupling risk coefficient and safe distance between metal structure and large loop transmitting antenna are derived. The influence of the radius of the large loop transmitting antenna, the radius of the equivalent receiving coil of the metal structure, the friction discharge spark load and the distance between the metal structure and the large loop transmitting antenna on the near-field coupling risk coefficient and the safe distance are analyzed. The simulation results show that the near-field coupling risk coefficient increases slightly at first and then decreases slightly or increases all the time with the increase of the radius of the large loop transmitting antenna. Under certain conditions, the friction discharge spark load can make the near-field coupling risk coefficient reach the peak value. When the radius of the large loop transmitting antenna is greater than or equal to the radius of the equivalent receiving coil of the metal structure, the near-field coupling risk coefficient at the peak value may exceed the critical value 0.46 of the near-field coupling risk coefficient. This may cause danger. When the radius of the large loop transmitting antenna is smaller than the radius of equivalent receiving coil of the metal structure, the near-field coupling risk coefficient at the peak value is less than the critical value 0.46 in most cases. This will not cause danger in most cases. Under certain conditions, the radius of the large loop transmitting antenna can make the near-field coupling risk coefficient reach the peak value. The near-field coupling risk coefficient at the peak value first increases and then decreases with the increase of the radius of equivalent receiving coil of the metal structure. It is more likely to exceed the critical value 0.46 of the near-field coupling risk coefficient, which is likely to cause danger in the gas environment. The safe distance increases with the increase of the radius of the large loop transmitting antenna. The safety of the electromagnetic wave energy on the friction discharge spark load decreases with the increase of the radius of the large loop transmitting antenna. When the radius of the large loop transmitting antenna is greater than or equal to the radius of the equivalent receiving coil of the metal structure, the safe distance increases with the increase of the radius of the equivalent receiving coil of the metal structure. The safety of the electromagnetic wave energy on the friction discharge spark load decreases with the increase of the radius of the equivalent receiving coil of the metal structure. When the radius of the large loop transmitting antenna is smaller than the radius of the equivalent receiving coil of the metal structure, the safe distance first increases slowly and then decreases with the increase of the radius of the equivalent receiving coil of the metal structure. The safety of the electromagnetic wave energy on the friction discharge spark load first decreases and then increases with the increase of the radius of the equivalent receiving coil of the metal structure.
first_indexed 2024-04-10T00:05:30Z
format Article
id doaj.art-5366800f14a04195a3543ade0ae8dd08
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-10T00:05:30Z
publishDate 2022-06-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-5366800f14a04195a3543ade0ae8dd082023-03-17T01:02:32ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2022-06-0148611812710.13272/j.issn.1671-251x.2022030093Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antennaFAN Sihan0YANG Wei1LIU Junbo2School of Electronic and Information Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electronic and Information Engineering, Beijing Jiaotong University, Beijing 100044, ChinaCCTEG Changzhou Research Institute, Changzhou 213015, ChinaWhen the metal structures distributed in the underground roadway are in the near-field of the large loop transmitting antenna, they will couple the electromagnetic wave energy of the large loop transmitting antenna. Once the metal structure has a breakpoint and friction occurs, it may produce friction discharge spark and ignite gas. This poses a threat to the safety of coal mine. In order to solve this problem, the safety of electromagnetic wave energy of underground metal structure near-field coupled large loop transmitting antenna is analyzed from two aspects of near-field coupling risk coefficient and safe distance. By establishing the equivalent circuit of electromagnetic wave energy of metal structure near-field coupled large loop transmitting antenna, the expressions of near-field coupling risk coefficient and safe distance between metal structure and large loop transmitting antenna are derived. The influence of the radius of the large loop transmitting antenna, the radius of the equivalent receiving coil of the metal structure, the friction discharge spark load and the distance between the metal structure and the large loop transmitting antenna on the near-field coupling risk coefficient and the safe distance are analyzed. The simulation results show that the near-field coupling risk coefficient increases slightly at first and then decreases slightly or increases all the time with the increase of the radius of the large loop transmitting antenna. Under certain conditions, the friction discharge spark load can make the near-field coupling risk coefficient reach the peak value. When the radius of the large loop transmitting antenna is greater than or equal to the radius of the equivalent receiving coil of the metal structure, the near-field coupling risk coefficient at the peak value may exceed the critical value 0.46 of the near-field coupling risk coefficient. This may cause danger. When the radius of the large loop transmitting antenna is smaller than the radius of equivalent receiving coil of the metal structure, the near-field coupling risk coefficient at the peak value is less than the critical value 0.46 in most cases. This will not cause danger in most cases. Under certain conditions, the radius of the large loop transmitting antenna can make the near-field coupling risk coefficient reach the peak value. The near-field coupling risk coefficient at the peak value first increases and then decreases with the increase of the radius of equivalent receiving coil of the metal structure. It is more likely to exceed the critical value 0.46 of the near-field coupling risk coefficient, which is likely to cause danger in the gas environment. The safe distance increases with the increase of the radius of the large loop transmitting antenna. The safety of the electromagnetic wave energy on the friction discharge spark load decreases with the increase of the radius of the large loop transmitting antenna. When the radius of the large loop transmitting antenna is greater than or equal to the radius of the equivalent receiving coil of the metal structure, the safe distance increases with the increase of the radius of the equivalent receiving coil of the metal structure. The safety of the electromagnetic wave energy on the friction discharge spark load decreases with the increase of the radius of the equivalent receiving coil of the metal structure. When the radius of the large loop transmitting antenna is smaller than the radius of the equivalent receiving coil of the metal structure, the safe distance first increases slowly and then decreases with the increase of the radius of the equivalent receiving coil of the metal structure. The safety of the electromagnetic wave energy on the friction discharge spark load first decreases and then increases with the increase of the radius of the equivalent receiving coil of the metal structure.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2022030093mine wireless communicationlarge loop transmitting antennametal structurenear-field couplingelectromagnetic wave energydischarge sparknear-field coupling risk coefficientsafe distance
spellingShingle FAN Sihan
YANG Wei
LIU Junbo
Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna
Gong-kuang zidonghua
mine wireless communication
large loop transmitting antenna
metal structure
near-field coupling
electromagnetic wave energy
discharge spark
near-field coupling risk coefficient
safe distance
title Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna
title_full Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna
title_fullStr Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna
title_full_unstemmed Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna
title_short Analysis of electromagnetic wave energy safety of underground metal structure near-field coupled large loop transmitting antenna
title_sort analysis of electromagnetic wave energy safety of underground metal structure near field coupled large loop transmitting antenna
topic mine wireless communication
large loop transmitting antenna
metal structure
near-field coupling
electromagnetic wave energy
discharge spark
near-field coupling risk coefficient
safe distance
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2022030093
work_keys_str_mv AT fansihan analysisofelectromagneticwaveenergysafetyofundergroundmetalstructurenearfieldcoupledlargelooptransmittingantenna
AT yangwei analysisofelectromagneticwaveenergysafetyofundergroundmetalstructurenearfieldcoupledlargelooptransmittingantenna
AT liujunbo analysisofelectromagneticwaveenergysafetyofundergroundmetalstructurenearfieldcoupledlargelooptransmittingantenna