Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers

Power transformers are still equipment of primary importance within power grids. The recent paradigm changes registered in the field of energy require the interconnection of electrical grids of much larger areas, even up to the level of an entire continent. In this context, knowing the state of the...

Full description

Bibliographic Details
Main Authors: Andrei Manea, Teodora Gorjanu, Andreea Lazeanu, Laurentiu Marius Dumitran
Format: Article
Language:English
Published: MDPI AG 2022-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/1/294
_version_ 1797625889797701632
author Andrei Manea
Teodora Gorjanu
Andreea Lazeanu
Laurentiu Marius Dumitran
author_facet Andrei Manea
Teodora Gorjanu
Andreea Lazeanu
Laurentiu Marius Dumitran
author_sort Andrei Manea
collection DOAJ
description Power transformers are still equipment of primary importance within power grids. The recent paradigm changes registered in the field of energy require the interconnection of electrical grids of much larger areas, even up to the level of an entire continent. In this context, knowing the state of the electrical equipment and that of the power transformers is an essential aspect to ensure safe operation conditions. The present work is related to the vulnerability of the oil–paper insulation systems of power transformers to different aging factors and their quick degradation under certain conditions. In this regard, the study proposed in this paper considers the measurement of DC resistivity on mineral oil samples contaminated with small amounts of accelerated aging oil under the action of high-strength electric field and partial discharges. In the absence of standardized procedures for accelerated electrical aging of mineral oil, an original method presented and discussed in previous articles is used. The obtained results clearly indicate that under the action of electrical stress, the mineral oil resistivity decreases significantly, showing that the oil’s electric properties worsen.
first_indexed 2024-03-11T10:02:52Z
format Article
id doaj.art-5375c336999f4292952161595ea6377c
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-11T10:02:52Z
publishDate 2022-12-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-5375c336999f4292952161595ea6377c2023-11-16T15:17:12ZengMDPI AGEnergies1996-10732022-12-0116129410.3390/en16010294Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power TransformersAndrei Manea0Teodora Gorjanu1Andreea Lazeanu2Laurentiu Marius Dumitran3Laboratory of Electrical Materials, University Politehnica of Bucharest, 060042 Bucharest, RomaniaLaboratory of Electrical Materials, University Politehnica of Bucharest, 060042 Bucharest, RomaniaLaboratory of Electrical Materials, University Politehnica of Bucharest, 060042 Bucharest, RomaniaLaboratory of Electrical Materials, University Politehnica of Bucharest, 060042 Bucharest, RomaniaPower transformers are still equipment of primary importance within power grids. The recent paradigm changes registered in the field of energy require the interconnection of electrical grids of much larger areas, even up to the level of an entire continent. In this context, knowing the state of the electrical equipment and that of the power transformers is an essential aspect to ensure safe operation conditions. The present work is related to the vulnerability of the oil–paper insulation systems of power transformers to different aging factors and their quick degradation under certain conditions. In this regard, the study proposed in this paper considers the measurement of DC resistivity on mineral oil samples contaminated with small amounts of accelerated aging oil under the action of high-strength electric field and partial discharges. In the absence of standardized procedures for accelerated electrical aging of mineral oil, an original method presented and discussed in previous articles is used. The obtained results clearly indicate that under the action of electrical stress, the mineral oil resistivity decreases significantly, showing that the oil’s electric properties worsen.https://www.mdpi.com/1996-1073/16/1/294mineral oilpower transformerselectric field and partial dischargesaccelerated aging
spellingShingle Andrei Manea
Teodora Gorjanu
Andreea Lazeanu
Laurentiu Marius Dumitran
Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers
Energies
mineral oil
power transformers
electric field and partial discharges
accelerated aging
title Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers
title_full Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers
title_fullStr Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers
title_full_unstemmed Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers
title_short Effect of Electrical Accelerated Aging on DC Resistivity of Mineral Oil Used in Power Transformers
title_sort effect of electrical accelerated aging on dc resistivity of mineral oil used in power transformers
topic mineral oil
power transformers
electric field and partial discharges
accelerated aging
url https://www.mdpi.com/1996-1073/16/1/294
work_keys_str_mv AT andreimanea effectofelectricalacceleratedagingondcresistivityofmineraloilusedinpowertransformers
AT teodoragorjanu effectofelectricalacceleratedagingondcresistivityofmineraloilusedinpowertransformers
AT andreealazeanu effectofelectricalacceleratedagingondcresistivityofmineraloilusedinpowertransformers
AT laurentiumariusdumitran effectofelectricalacceleratedagingondcresistivityofmineraloilusedinpowertransformers