Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit

Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted comp...

Full description

Bibliographic Details
Main Authors: Maryam Babaei, Marzieh Khalili, Arash Khalili, Pegah Sharifian
Format: Article
Language:fas
Published: Hamadan University of Medical Sciences 2022-06-01
Series:پژوهان
Subjects:
Online Access:http://psj.umsha.ac.ir/article-1-807-en.pdf
_version_ 1811176275999457280
author Maryam Babaei
Marzieh Khalili
Arash Khalili
Pegah Sharifian
author_facet Maryam Babaei
Marzieh Khalili
Arash Khalili
Pegah Sharifian
author_sort Maryam Babaei
collection DOAJ
description Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe for temperature control in premature infants under radiant heating admitted to neonatal intensive care units in Hamadan in 2020. Materials and Methods: In this cross-sectional descriptive study, 140 infants aged 34 to 37 weeks admitted to neonatal intensive care units in Hamadan in 2020 who met the inclusion criteria were included in the study by available methods. The incubator temperature was set at 37 degrees and it was the same for all infants. For each infant, the probe was attached to the forehead, chest between the ribs, right axillar, arms adjacent to the nipple, right armpit, back of the legs, and upper thigh, respectively. The baby's temperature displayed on the digital warmer screen was recorded two minutes later. A researcher-made checklist was used to record the data and the data were analyzed using t-test and Paired t-test. Results: The correlation between left and right axillary was highest, meaning that the best location for the incubator thermometer probe, after the left axillary is the right axillary (r = 0.91, P = 0.001). Conclusions: The most suitable place for connecting skin probe for temperature control after left axillary, is the right axillary.
first_indexed 2024-04-10T19:50:34Z
format Article
id doaj.art-5382daa2a21943d8a339bb2b54c72e90
institution Directory Open Access Journal
issn 1029-7863
2423-6276
language fas
last_indexed 2024-04-10T19:50:34Z
publishDate 2022-06-01
publisher Hamadan University of Medical Sciences
record_format Article
series پژوهان
spelling doaj.art-5382daa2a21943d8a339bb2b54c72e902023-01-28T09:14:28ZfasHamadan University of Medical Sciencesپژوهان1029-78632423-62762022-06-0120312713210.52547/psj.20.3.127Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care UnitMaryam Babaei0https://orcid.org/0000-0001-6646-6135Marzieh Khalili1https://orcid.org/0000-0001-7666-4362Arash Khalili2https://orcid.org/0000-0002-6061-1538 Pegah Sharifian 3https://orcid.org/0000-0002-2893-402XDepartment of Nursing, Tuyserkan Branch, Islamic Azad University, Tuyserkan, Iran Department of Pediatric Nursing, Yasouj University of Medical Sciences, Yasouj, Iran Mother and Child Care Research Center, Hamadan University of Medical Sciences, Hamadan, Iran Nursing Care Research Center (NCRC), School of Nursing and Midwifery, Iran University of Medical Sciences, Tehran, Iran Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe for temperature control in premature infants under radiant heating admitted to neonatal intensive care units in Hamadan in 2020. Materials and Methods: In this cross-sectional descriptive study, 140 infants aged 34 to 37 weeks admitted to neonatal intensive care units in Hamadan in 2020 who met the inclusion criteria were included in the study by available methods. The incubator temperature was set at 37 degrees and it was the same for all infants. For each infant, the probe was attached to the forehead, chest between the ribs, right axillar, arms adjacent to the nipple, right armpit, back of the legs, and upper thigh, respectively. The baby's temperature displayed on the digital warmer screen was recorded two minutes later. A researcher-made checklist was used to record the data and the data were analyzed using t-test and Paired t-test. Results: The correlation between left and right axillary was highest, meaning that the best location for the incubator thermometer probe, after the left axillary is the right axillary (r = 0.91, P = 0.001). Conclusions: The most suitable place for connecting skin probe for temperature control after left axillary, is the right axillary. http://psj.umsha.ac.ir/article-1-807-en.pdfthermometertemperatureneonateskin probe
spellingShingle Maryam Babaei
Marzieh Khalili
Arash Khalili
Pegah Sharifian
Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
پژوهان
thermometer
temperature
neonate
skin probe
title Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
title_full Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
title_fullStr Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
title_full_unstemmed Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
title_short Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
title_sort evaluation of suitable connection point of skin probe for temperature control in premature infants under radiant heating admitted to neonatal intensive care unit
topic thermometer
temperature
neonate
skin probe
url http://psj.umsha.ac.ir/article-1-807-en.pdf
work_keys_str_mv AT maryambabaei evaluationofsuitableconnectionpointofskinprobefortemperaturecontrolinprematureinfantsunderradiantheatingadmittedtoneonatalintensivecareunit
AT marziehkhalili evaluationofsuitableconnectionpointofskinprobefortemperaturecontrolinprematureinfantsunderradiantheatingadmittedtoneonatalintensivecareunit
AT arashkhalili evaluationofsuitableconnectionpointofskinprobefortemperaturecontrolinprematureinfantsunderradiantheatingadmittedtoneonatalintensivecareunit
AT pegahsharifian evaluationofsuitableconnectionpointofskinprobefortemperaturecontrolinprematureinfantsunderradiantheatingadmittedtoneonatalintensivecareunit