“Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience
Purpose: To report on the accuracy of automated delineation, treatment plan quality, and duration of an in-silico “scan-(pre)plan-treat” (SPT) workflow for vertebral bone metastases using a 1 × 8 Gy regimen. Method and Materials: The cloud-based emulator system of the Ethos therapy system was used t...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-11-01
|
Series: | Advances in Radiation Oncology |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2452109423000878 |
_version_ | 1797812791730503680 |
---|---|
author | Eva Oldenburger, MD Robin De Roover, PhD Kenneth Poels, PhD Tom Depuydt, PhD Sofie Isebaert, PhD Karin Haustermans, MD, PhD |
author_facet | Eva Oldenburger, MD Robin De Roover, PhD Kenneth Poels, PhD Tom Depuydt, PhD Sofie Isebaert, PhD Karin Haustermans, MD, PhD |
author_sort | Eva Oldenburger, MD |
collection | DOAJ |
description | Purpose: To report on the accuracy of automated delineation, treatment plan quality, and duration of an in-silico “scan-(pre)plan-treat” (SPT) workflow for vertebral bone metastases using a 1 × 8 Gy regimen. Method and Materials: The cloud-based emulator system of the Ethos therapy system was used to adapt an organ-at-risk-sparing preplan created on the diagnostic CT to the anatomy-of-the-day using the cone beam CT made before treatment. Results: SPT using the Ethos emulator system resulted in relatively good coverage of the PTV and acceptable dose to the OAR. Delivery time and plan homogeneity was the best for 7-field IMRT plan template. Conclusions: A SPT workflow formula results in a highly conformal treatment delivery while maintaining an acceptable timeframe for the patient on the treatment couch. |
first_indexed | 2024-03-13T07:42:41Z |
format | Article |
id | doaj.art-541090d8d7ec464d8852a33056ca55f3 |
institution | Directory Open Access Journal |
issn | 2452-1094 |
language | English |
last_indexed | 2024-03-13T07:42:41Z |
publishDate | 2023-11-01 |
publisher | Elsevier |
record_format | Article |
series | Advances in Radiation Oncology |
spelling | doaj.art-541090d8d7ec464d8852a33056ca55f32023-06-03T04:22:28ZengElsevierAdvances in Radiation Oncology2452-10942023-11-0186101258“Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico ExperienceEva Oldenburger, MD0Robin De Roover, PhD1Kenneth Poels, PhD2Tom Depuydt, PhD3Sofie Isebaert, PhD4Karin Haustermans, MD, PhD5Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium; Department of Oncology, KU Leuven, Leuven, Belgium; Department of Palliative Care, University Hospitals Leuven, Leuven, Belgium; Corresponding author: Eva Oldenburger, MDDepartment of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium; Department of Oncology, KU Leuven, Leuven, BelgiumDepartment of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium; Department of Oncology, KU Leuven, Leuven, BelgiumDepartment of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium; Department of Oncology, KU Leuven, Leuven, BelgiumDepartment of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium; Department of Oncology, KU Leuven, Leuven, BelgiumDepartment of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium; Department of Oncology, KU Leuven, Leuven, BelgiumPurpose: To report on the accuracy of automated delineation, treatment plan quality, and duration of an in-silico “scan-(pre)plan-treat” (SPT) workflow for vertebral bone metastases using a 1 × 8 Gy regimen. Method and Materials: The cloud-based emulator system of the Ethos therapy system was used to adapt an organ-at-risk-sparing preplan created on the diagnostic CT to the anatomy-of-the-day using the cone beam CT made before treatment. Results: SPT using the Ethos emulator system resulted in relatively good coverage of the PTV and acceptable dose to the OAR. Delivery time and plan homogeneity was the best for 7-field IMRT plan template. Conclusions: A SPT workflow formula results in a highly conformal treatment delivery while maintaining an acceptable timeframe for the patient on the treatment couch.http://www.sciencedirect.com/science/article/pii/S2452109423000878 |
spellingShingle | Eva Oldenburger, MD Robin De Roover, PhD Kenneth Poels, PhD Tom Depuydt, PhD Sofie Isebaert, PhD Karin Haustermans, MD, PhD “Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience Advances in Radiation Oncology |
title | “Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience |
title_full | “Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience |
title_fullStr | “Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience |
title_full_unstemmed | “Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience |
title_short | “Scan-(pre)Plan-Treat” Workflow for Bone Metastases Using the Ethos Therapy System: A Single-Center, In Silico Experience |
title_sort | scan pre plan treat workflow for bone metastases using the ethos therapy system a single center in silico experience |
url | http://www.sciencedirect.com/science/article/pii/S2452109423000878 |
work_keys_str_mv | AT evaoldenburgermd scanpreplantreatworkflowforbonemetastasesusingtheethostherapysystemasinglecenterinsilicoexperience AT robinderooverphd scanpreplantreatworkflowforbonemetastasesusingtheethostherapysystemasinglecenterinsilicoexperience AT kennethpoelsphd scanpreplantreatworkflowforbonemetastasesusingtheethostherapysystemasinglecenterinsilicoexperience AT tomdepuydtphd scanpreplantreatworkflowforbonemetastasesusingtheethostherapysystemasinglecenterinsilicoexperience AT sofieisebaertphd scanpreplantreatworkflowforbonemetastasesusingtheethostherapysystemasinglecenterinsilicoexperience AT karinhaustermansmdphd scanpreplantreatworkflowforbonemetastasesusingtheethostherapysystemasinglecenterinsilicoexperience |