A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment

The main method for estimating the level of arterial blood oxygenation is pulse oximetry, which has the advantages of being fast, simple, reliable, and non-invasive. However, in well-known pulse oximeters, oxygen saturation is determined only by hemoglobin functional fractions, which reduces the dev...

Full description

Bibliographic Details
Main Authors: Anton Sheikus, Igor Prasol, Oleh Datsok
Format: Article
Language:English
Published: National Aerospace University «Kharkiv Aviation Institute» 2024-02-01
Series:Радіоелектронні і комп'ютерні системи
Subjects:
Online Access:http://nti.khai.edu/ojs/index.php/reks/article/view/2273
_version_ 1797220397523927040
author Anton Sheikus
Igor Prasol
Oleh Datsok
author_facet Anton Sheikus
Igor Prasol
Oleh Datsok
author_sort Anton Sheikus
collection DOAJ
description The main method for estimating the level of arterial blood oxygenation is pulse oximetry, which has the advantages of being fast, simple, reliable, and non-invasive. However, in well-known pulse oximeters, oxygen saturation is determined only by hemoglobin functional fractions, which reduces the device accuracy and is unacceptable in certain clinical cases. The known pulse oximeter improvement that considers the dysfunctional fraction concentration, especially carboxyhemoglobin, when measuring the level of blood oxygenation is an actual scientific and technical task. The research subjects. Mathematical, algorithmic, and technical support of a pulse oximeter that measures blood oxygenation levels considering the carboxyhemoglobin concentration. Objective. To expand the pulse oximeter functionality to consider the concentration of carboxyhemoglobin in arterial blood. Methods. Methods of computer simulation for developing a model and estimating the pulse oximeter accuracy that measures the blood oxygenation level considering the carboxyhemoglobin concentration. Results. The theoretical statements of measuring the level of blood oxygenation considering the carboxyhemoglobin concentration and the simplest pulse oximeter structural diagram for measuring are developed. An additional LED used in the pulse oximeter is proposed, and the wavelength choice is justified on the condition of maximizing the carboxyhemoglobin contribution to the optical density of the biological object. Computer models of a traditional pulse oximeter and a pulse oximeter with an additional LED were developed, simulation research was conducted using the developed models, and the device accuracy for measuring the level of blood oxygenation was estimated considering the carboxyhemoglobin concentration. Conclusions. Simulation studies based on the developed models show that the proposed pulse oximeter, compared with the known one, allows determining and estimating a decrease in blood oxygenation caused by the carboxyhemoglobin concentration increasing in the patient’s blood. Considering that light is also absorbed by the third derivative of hemoglobin, carboxyhemoglobin, increases the accuracy of the proposed pulse oximeter in measuring functional saturation.
first_indexed 2024-04-24T12:48:54Z
format Article
id doaj.art-544d8b7c58714ac8bd36d8ae430ee450
institution Directory Open Access Journal
issn 1814-4225
2663-2012
language English
last_indexed 2024-04-24T12:48:54Z
publishDate 2024-02-01
publisher National Aerospace University «Kharkiv Aviation Institute»
record_format Article
series Радіоелектронні і комп'ютерні системи
spelling doaj.art-544d8b7c58714ac8bd36d8ae430ee4502024-04-06T08:29:50ZengNational Aerospace University «Kharkiv Aviation Institute»Радіоелектронні і комп'ютерні системи1814-42252663-20122024-02-0120241364710.32620/reks.2024.1.032099A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessmentAnton Sheikus0Igor Prasol1Oleh Datsok2Ukrainian State University of Chemical Technology, DniproKharkiv National University of Radio Electronics, KharkivKharkiv National University of Radio Electronics, KharkivThe main method for estimating the level of arterial blood oxygenation is pulse oximetry, which has the advantages of being fast, simple, reliable, and non-invasive. However, in well-known pulse oximeters, oxygen saturation is determined only by hemoglobin functional fractions, which reduces the device accuracy and is unacceptable in certain clinical cases. The known pulse oximeter improvement that considers the dysfunctional fraction concentration, especially carboxyhemoglobin, when measuring the level of blood oxygenation is an actual scientific and technical task. The research subjects. Mathematical, algorithmic, and technical support of a pulse oximeter that measures blood oxygenation levels considering the carboxyhemoglobin concentration. Objective. To expand the pulse oximeter functionality to consider the concentration of carboxyhemoglobin in arterial blood. Methods. Methods of computer simulation for developing a model and estimating the pulse oximeter accuracy that measures the blood oxygenation level considering the carboxyhemoglobin concentration. Results. The theoretical statements of measuring the level of blood oxygenation considering the carboxyhemoglobin concentration and the simplest pulse oximeter structural diagram for measuring are developed. An additional LED used in the pulse oximeter is proposed, and the wavelength choice is justified on the condition of maximizing the carboxyhemoglobin contribution to the optical density of the biological object. Computer models of a traditional pulse oximeter and a pulse oximeter with an additional LED were developed, simulation research was conducted using the developed models, and the device accuracy for measuring the level of blood oxygenation was estimated considering the carboxyhemoglobin concentration. Conclusions. Simulation studies based on the developed models show that the proposed pulse oximeter, compared with the known one, allows determining and estimating a decrease in blood oxygenation caused by the carboxyhemoglobin concentration increasing in the patient’s blood. Considering that light is also absorbed by the third derivative of hemoglobin, carboxyhemoglobin, increases the accuracy of the proposed pulse oximeter in measuring functional saturation.http://nti.khai.edu/ojs/index.php/reks/article/view/2273pulse oximetryoxygenationcarboxyhemoglobindevelopmentcomputer modelsaturationhypoxemiaaccuracy
spellingShingle Anton Sheikus
Igor Prasol
Oleh Datsok
A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment
Радіоелектронні і комп'ютерні системи
pulse oximetry
oxygenation
carboxyhemoglobin
development
computer model
saturation
hypoxemia
accuracy
title A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment
title_full A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment
title_fullStr A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment
title_full_unstemmed A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment
title_short A pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration: principles of development, computer model and accuracy assessment
title_sort pulse oximeter for measuring the blood oxygenation level considering the carboxyhemoglobin concentration principles of development computer model and accuracy assessment
topic pulse oximetry
oxygenation
carboxyhemoglobin
development
computer model
saturation
hypoxemia
accuracy
url http://nti.khai.edu/ojs/index.php/reks/article/view/2273
work_keys_str_mv AT antonsheikus apulseoximeterformeasuringthebloodoxygenationlevelconsideringthecarboxyhemoglobinconcentrationprinciplesofdevelopmentcomputermodelandaccuracyassessment
AT igorprasol apulseoximeterformeasuringthebloodoxygenationlevelconsideringthecarboxyhemoglobinconcentrationprinciplesofdevelopmentcomputermodelandaccuracyassessment
AT olehdatsok apulseoximeterformeasuringthebloodoxygenationlevelconsideringthecarboxyhemoglobinconcentrationprinciplesofdevelopmentcomputermodelandaccuracyassessment
AT antonsheikus pulseoximeterformeasuringthebloodoxygenationlevelconsideringthecarboxyhemoglobinconcentrationprinciplesofdevelopmentcomputermodelandaccuracyassessment
AT igorprasol pulseoximeterformeasuringthebloodoxygenationlevelconsideringthecarboxyhemoglobinconcentrationprinciplesofdevelopmentcomputermodelandaccuracyassessment
AT olehdatsok pulseoximeterformeasuringthebloodoxygenationlevelconsideringthecarboxyhemoglobinconcentrationprinciplesofdevelopmentcomputermodelandaccuracyassessment