Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.

<h4>Introduction</h4>Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examin...

Full description

Bibliographic Details
Main Authors: Seth O'Neill, Alice Weeks, Jens Eg Nørgaard, Martin Gronbech Jorgensen
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2023-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0282395
_version_ 1797843040430194688
author Seth O'Neill
Alice Weeks
Jens Eg Nørgaard
Martin Gronbech Jorgensen
author_facet Seth O'Neill
Alice Weeks
Jens Eg Nørgaard
Martin Gronbech Jorgensen
author_sort Seth O'Neill
collection DOAJ
description <h4>Introduction</h4>Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor strength due to the cumbersome, stationary and expensive nature of an isokinetic dynamometer (IKD), known as the "Gold Standard". This study examined the validity and reliability of a fast, easy and portable device for assessing plantarflexion.<h4>Methods</h4>Validity between the Cybex NORM® by Humac and the C-Station by Fysiometer was explored using Pearson correlation coefficient. Participants were randomly selected to start in the Cybex NORM® or the FysioMeter C-Station. Intra-rater reliability on the C-station was investigated by test-retest two days apart using Intraclass Correlation Coefficient (ICC). All testing involved isometric maximal force of the soleus muscle with the knee at 90 degrees flexion.<h4>Results</h4>40 healthy university students were recruited for the validity part, while 65 healthy university students were recruited for the reliability part of the study. The mean peak torque on the IKD was 198.55Nm (SD 94.45) versus 1443.88 (412.82)N on the C-Station. The results of the Pearson correlation revealed an r-value of r = 0.72 with a 95%CI 0.52-0.84. The test re-test reliability was calculated as an ICC of 0.91 with a (95%CI 0.86-0.94).<h4>Conclusions</h4>The C-Station by Fysiometer appears to provide valid measures and have excellent reliability for Plantar flexor isometric strength. It would appear suitable for both clinical and research work.
first_indexed 2024-04-09T16:58:03Z
format Article
id doaj.art-548819d3f4c8477ba58f36fae113d93f
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-09T16:58:03Z
publishDate 2023-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-548819d3f4c8477ba58f36fae113d93f2023-04-21T05:34:10ZengPublic Library of Science (PLoS)PLoS ONE1932-62032023-01-01183e028239510.1371/journal.pone.0282395Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.Seth O'NeillAlice WeeksJens Eg NørgaardMartin Gronbech Jorgensen<h4>Introduction</h4>Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor strength due to the cumbersome, stationary and expensive nature of an isokinetic dynamometer (IKD), known as the "Gold Standard". This study examined the validity and reliability of a fast, easy and portable device for assessing plantarflexion.<h4>Methods</h4>Validity between the Cybex NORM® by Humac and the C-Station by Fysiometer was explored using Pearson correlation coefficient. Participants were randomly selected to start in the Cybex NORM® or the FysioMeter C-Station. Intra-rater reliability on the C-station was investigated by test-retest two days apart using Intraclass Correlation Coefficient (ICC). All testing involved isometric maximal force of the soleus muscle with the knee at 90 degrees flexion.<h4>Results</h4>40 healthy university students were recruited for the validity part, while 65 healthy university students were recruited for the reliability part of the study. The mean peak torque on the IKD was 198.55Nm (SD 94.45) versus 1443.88 (412.82)N on the C-Station. The results of the Pearson correlation revealed an r-value of r = 0.72 with a 95%CI 0.52-0.84. The test re-test reliability was calculated as an ICC of 0.91 with a (95%CI 0.86-0.94).<h4>Conclusions</h4>The C-Station by Fysiometer appears to provide valid measures and have excellent reliability for Plantar flexor isometric strength. It would appear suitable for both clinical and research work.https://doi.org/10.1371/journal.pone.0282395
spellingShingle Seth O'Neill
Alice Weeks
Jens Eg Nørgaard
Martin Gronbech Jorgensen
Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.
PLoS ONE
title Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.
title_full Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.
title_fullStr Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.
title_full_unstemmed Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.
title_short Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.
title_sort validity and intrarater reliability of a novel device for assessing plantar flexor strength
url https://doi.org/10.1371/journal.pone.0282395
work_keys_str_mv AT sethoneill validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength
AT aliceweeks validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength
AT jensegnørgaard validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength
AT martingronbechjorgensen validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength