Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars

Shear failure is an unfavorable phenomenon as it is a brittle type of failure; however, adding rebars and fibers to a concrete beam can minimize its detrimental effects. The objective of this study was to experimentally investigate the shear behavior of high-strength concrete (HC) beams reinforced w...

Full description

Bibliographic Details
Main Authors: Amirhassan Alizadeh, Taleb Moradi Shaghaghi, Masoud Pourbaba, Seyed Saeed Mirrezaei, Yousef Zandi
Format: Article
Language:English
Published: MDPI AG 2023-08-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/13/8/2106
_version_ 1797585239145447424
author Amirhassan Alizadeh
Taleb Moradi Shaghaghi
Masoud Pourbaba
Seyed Saeed Mirrezaei
Yousef Zandi
author_facet Amirhassan Alizadeh
Taleb Moradi Shaghaghi
Masoud Pourbaba
Seyed Saeed Mirrezaei
Yousef Zandi
author_sort Amirhassan Alizadeh
collection DOAJ
description Shear failure is an unfavorable phenomenon as it is a brittle type of failure; however, adding rebars and fibers to a concrete beam can minimize its detrimental effects. The objective of this study was to experimentally investigate the shear behavior of high-strength concrete (HC) beams reinforced with hooked-end (H) steel fibers and high-strength steel (HS) rebars under three-point bending tests. For this purpose, nine HC beams (300 × 250 × 1150 mm in dimension) were cast with 0%, 1%, and 2% H fibers by volume in three longitudinal rebar ratios (i.e., 1.5%, 2.0%, and 3.1%) and compared with beams without fibers. Furthermore, numerical analyses were performed to validate the experimental results and compare them with design codes. The results showed that, irrespective of the fiber content or longitudinal rebar ratio, the beams failed in shear. Increasing the rebar ratio and fiber content increased the shear capacity to as high as 100% (for the specimen with 3% rebar and 2% fiber compared to its counterpart with 1% rebar and 2% fiber). In addition, the research-based equations proposed in the literature either overestimated or underestimated the shear capacity of fibrous HC beams significantly. The level of overestimation or underestimation was closely related to the sensitivity of the proposed model to the shear span ratio and the fiber content. Rebars proved to be more beneficial in contributing to the shear capacity, but the rate of this positive contribution decreased as the fiber ratio increased. Finally, the inverse analysis approach adopted herein proved to be an efficient tool in estimating the shear response of fiber-reinforced beams failing in shear (margin of error: less than 10%).
first_indexed 2024-03-11T00:04:16Z
format Article
id doaj.art-54ab0a68bb2944d2898ba111afecf126
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-11T00:04:16Z
publishDate 2023-08-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-54ab0a68bb2944d2898ba111afecf1262023-11-19T00:31:35ZengMDPI AGBuildings2075-53092023-08-01138210610.3390/buildings13082106Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel RebarsAmirhassan Alizadeh0Taleb Moradi Shaghaghi1Masoud Pourbaba2Seyed Saeed Mirrezaei3Yousef Zandi4Department of Civil Engineering, Tabriz Branch, Islamic Azad University, Tabriz 5157944533, IranDepartment of Civil Engineering, Tabriz Branch, Islamic Azad University, Tabriz 5157944533, IranDepartment of Civil Engineering, Maragheh Branch, Islamic Azad University, Maragheh 5519747591, IranDepartment of Civil Engineering, Tabriz Branch, Islamic Azad University, Tabriz 5157944533, IranDepartment of Civil Engineering, Tabriz Branch, Islamic Azad University, Tabriz 5157944533, IranShear failure is an unfavorable phenomenon as it is a brittle type of failure; however, adding rebars and fibers to a concrete beam can minimize its detrimental effects. The objective of this study was to experimentally investigate the shear behavior of high-strength concrete (HC) beams reinforced with hooked-end (H) steel fibers and high-strength steel (HS) rebars under three-point bending tests. For this purpose, nine HC beams (300 × 250 × 1150 mm in dimension) were cast with 0%, 1%, and 2% H fibers by volume in three longitudinal rebar ratios (i.e., 1.5%, 2.0%, and 3.1%) and compared with beams without fibers. Furthermore, numerical analyses were performed to validate the experimental results and compare them with design codes. The results showed that, irrespective of the fiber content or longitudinal rebar ratio, the beams failed in shear. Increasing the rebar ratio and fiber content increased the shear capacity to as high as 100% (for the specimen with 3% rebar and 2% fiber compared to its counterpart with 1% rebar and 2% fiber). In addition, the research-based equations proposed in the literature either overestimated or underestimated the shear capacity of fibrous HC beams significantly. The level of overestimation or underestimation was closely related to the sensitivity of the proposed model to the shear span ratio and the fiber content. Rebars proved to be more beneficial in contributing to the shear capacity, but the rate of this positive contribution decreased as the fiber ratio increased. Finally, the inverse analysis approach adopted herein proved to be an efficient tool in estimating the shear response of fiber-reinforced beams failing in shear (margin of error: less than 10%).https://www.mdpi.com/2075-5309/13/8/2106fiber-reinforced concrete (FRC)high-strength concrete (HC)high-strength steel (HS)hooked-end steel fiber
spellingShingle Amirhassan Alizadeh
Taleb Moradi Shaghaghi
Masoud Pourbaba
Seyed Saeed Mirrezaei
Yousef Zandi
Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
Buildings
fiber-reinforced concrete (FRC)
high-strength concrete (HC)
high-strength steel (HS)
hooked-end steel fiber
title Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
title_full Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
title_fullStr Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
title_full_unstemmed Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
title_short Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
title_sort experimental investigation of shear behavior in high strength concrete beams reinforced with hooked end steel fibers and high strength steel rebars
topic fiber-reinforced concrete (FRC)
high-strength concrete (HC)
high-strength steel (HS)
hooked-end steel fiber
url https://www.mdpi.com/2075-5309/13/8/2106
work_keys_str_mv AT amirhassanalizadeh experimentalinvestigationofshearbehaviorinhighstrengthconcretebeamsreinforcedwithhookedendsteelfibersandhighstrengthsteelrebars
AT talebmoradishaghaghi experimentalinvestigationofshearbehaviorinhighstrengthconcretebeamsreinforcedwithhookedendsteelfibersandhighstrengthsteelrebars
AT masoudpourbaba experimentalinvestigationofshearbehaviorinhighstrengthconcretebeamsreinforcedwithhookedendsteelfibersandhighstrengthsteelrebars
AT seyedsaeedmirrezaei experimentalinvestigationofshearbehaviorinhighstrengthconcretebeamsreinforcedwithhookedendsteelfibersandhighstrengthsteelrebars
AT yousefzandi experimentalinvestigationofshearbehaviorinhighstrengthconcretebeamsreinforcedwithhookedendsteelfibersandhighstrengthsteelrebars