An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements

This study aimed to evaluate the applicability of the outdoor air enthalpy difference method for air source heat pumps (ASHP) in operation through quantitative analysis using field tests. In this context, field measurements were performed on a single ASHP, and the results were compared with other in...

Full description

Bibliographic Details
Main Authors: Jinwoong Son, Junho Hong, Taeyun Aum
Format: Article
Language:English
Published: MDPI AG 2023-02-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/13/2/448
_version_ 1797621924236361728
author Jinwoong Son
Junho Hong
Taeyun Aum
author_facet Jinwoong Son
Junho Hong
Taeyun Aum
author_sort Jinwoong Son
collection DOAJ
description This study aimed to evaluate the applicability of the outdoor air enthalpy difference method for air source heat pumps (ASHP) in operation through quantitative analysis using field tests. In this context, field measurements were performed on a single ASHP, and the results were compared with other in situ measurement methods. The main results are as follows. The analysis of the distribution of the discharge temperature of the outdoor unit suggested that the temperature between the hub and tip on the outlet of the outdoor unit can represent the discharge temperature, enabling further simplification of measurement procedures. The mean error of the average cooling capacity using the outdoor air enthalpy difference method was 8% compared to that of the in situ refrigerant enthalpy difference method. In summary, the in situ outdoor unit air enthalpy difference method may require additional measurements to increase reliability, but considering the advantage of relatively easy measurement, it is considered suitable for short-term in situ diagnosis of ASHP performance.
first_indexed 2024-03-11T09:03:59Z
format Article
id doaj.art-54c87c3fb0c14c4e8b0d140ede39b381
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-11T09:03:59Z
publishDate 2023-02-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-54c87c3fb0c14c4e8b0d140ede39b3812023-11-16T19:32:48ZengMDPI AGBuildings2075-53092023-02-0113244810.3390/buildings13020448An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ MeasurementsJinwoong Son0Junho Hong1Taeyun Aum2Hanil Mechanical & Electrical Consultants, Seoul 07271, Republic of KoreaHanil Mechanical & Electrical Consultants, Seoul 07271, Republic of KoreaHanil Mechanical & Electrical Consultants, Seoul 07271, Republic of KoreaThis study aimed to evaluate the applicability of the outdoor air enthalpy difference method for air source heat pumps (ASHP) in operation through quantitative analysis using field tests. In this context, field measurements were performed on a single ASHP, and the results were compared with other in situ measurement methods. The main results are as follows. The analysis of the distribution of the discharge temperature of the outdoor unit suggested that the temperature between the hub and tip on the outlet of the outdoor unit can represent the discharge temperature, enabling further simplification of measurement procedures. The mean error of the average cooling capacity using the outdoor air enthalpy difference method was 8% compared to that of the in situ refrigerant enthalpy difference method. In summary, the in situ outdoor unit air enthalpy difference method may require additional measurements to increase reliability, but considering the advantage of relatively easy measurement, it is considered suitable for short-term in situ diagnosis of ASHP performance.https://www.mdpi.com/2075-5309/13/2/448ASHPenergy performancein situ measurementauditexisting building
spellingShingle Jinwoong Son
Junho Hong
Taeyun Aum
An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements
Buildings
ASHP
energy performance
in situ measurement
audit
existing building
title An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements
title_full An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements
title_fullStr An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements
title_full_unstemmed An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements
title_short An Experimental Study of the Applicability of the Outdoor Air Enthalpy Difference Method for Air Source Heat Pumps in Operation through In Situ Measurements
title_sort experimental study of the applicability of the outdoor air enthalpy difference method for air source heat pumps in operation through in situ measurements
topic ASHP
energy performance
in situ measurement
audit
existing building
url https://www.mdpi.com/2075-5309/13/2/448
work_keys_str_mv AT jinwoongson anexperimentalstudyoftheapplicabilityoftheoutdoorairenthalpydifferencemethodforairsourceheatpumpsinoperationthroughinsitumeasurements
AT junhohong anexperimentalstudyoftheapplicabilityoftheoutdoorairenthalpydifferencemethodforairsourceheatpumpsinoperationthroughinsitumeasurements
AT taeyunaum anexperimentalstudyoftheapplicabilityoftheoutdoorairenthalpydifferencemethodforairsourceheatpumpsinoperationthroughinsitumeasurements
AT jinwoongson experimentalstudyoftheapplicabilityoftheoutdoorairenthalpydifferencemethodforairsourceheatpumpsinoperationthroughinsitumeasurements
AT junhohong experimentalstudyoftheapplicabilityoftheoutdoorairenthalpydifferencemethodforairsourceheatpumpsinoperationthroughinsitumeasurements
AT taeyunaum experimentalstudyoftheapplicabilityoftheoutdoorairenthalpydifferencemethodforairsourceheatpumpsinoperationthroughinsitumeasurements