Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes

This paper presents new graphical tools, which can quickly identify all thermal exergy losses occurring in process design particularly in condensers/evaporators of low-temperature processes. Although the Omega -H diagram is a powerful tool for getting insights about exergy loss in a heat exchanger n...

Full description

Bibliographic Details
Main Authors: M. Hassan Panjeshahi, Nassim Tahouni
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2019-10-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/10524
_version_ 1819284242899664896
author M. Hassan Panjeshahi
Nassim Tahouni
author_facet M. Hassan Panjeshahi
Nassim Tahouni
author_sort M. Hassan Panjeshahi
collection DOAJ
description This paper presents new graphical tools, which can quickly identify all thermal exergy losses occurring in process design particularly in condensers/evaporators of low-temperature processes. Although the Omega -H diagram is a powerful tool for getting insights about exergy loss in a heat exchanger network (HEN), the calculation of the enclosed area is not straightforward due to non-linearity of the curves. The Omega Composite Curves (OCCs) and Omega Grand Composite Curve (OGCC) developed in this research are new graphical tools that can be applied to any process, including sub-ambient processes. These curves are linear, and all enclosed areas have a rectangular shape. So, all thermal exergy losses can readily be calculated and also necessary modifications to enhance the efficiency of refrigeration systems, either in new design or retrofit study can graphically be suggested. To demonstrate the capability of the new graphical tools, two ammonia refrigeration cycles (one single-stage and one three-stage) have been designed to fulfil the cooling demand of a sub-ambient process and achieve minimum shaft work requirements. The exergy loss associated with each unit in the refrigeration cycle is directly calculated from the OGCC diagram. This is a convenient tool for calculation of exergy losses and can be used to compute the enclosed areas between the OGCC and the condenser/evaporator horizontal lines. The enclosed areas show that exergy loss for 3-stage compression is much less than that in the 1-stage cycle. Also, for the throttling valve, the exergy loss in the 3-stage refrigeration is considerably less than that in the 1-stage cycle. The new linear curves can easily be plotted and implemented to show the share of inefficiencies occurring in different unit operations.
first_indexed 2024-12-24T01:44:16Z
format Article
id doaj.art-550b4adfb29449cab18291d9bcb9b446
institution Directory Open Access Journal
issn 2283-9216
language English
last_indexed 2024-12-24T01:44:16Z
publishDate 2019-10-01
publisher AIDIC Servizi S.r.l.
record_format Article
series Chemical Engineering Transactions
spelling doaj.art-550b4adfb29449cab18291d9bcb9b4462022-12-21T17:21:55ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162019-10-017610.3303/CET1976073Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient ProcessesM. Hassan PanjeshahiNassim TahouniThis paper presents new graphical tools, which can quickly identify all thermal exergy losses occurring in process design particularly in condensers/evaporators of low-temperature processes. Although the Omega -H diagram is a powerful tool for getting insights about exergy loss in a heat exchanger network (HEN), the calculation of the enclosed area is not straightforward due to non-linearity of the curves. The Omega Composite Curves (OCCs) and Omega Grand Composite Curve (OGCC) developed in this research are new graphical tools that can be applied to any process, including sub-ambient processes. These curves are linear, and all enclosed areas have a rectangular shape. So, all thermal exergy losses can readily be calculated and also necessary modifications to enhance the efficiency of refrigeration systems, either in new design or retrofit study can graphically be suggested. To demonstrate the capability of the new graphical tools, two ammonia refrigeration cycles (one single-stage and one three-stage) have been designed to fulfil the cooling demand of a sub-ambient process and achieve minimum shaft work requirements. The exergy loss associated with each unit in the refrigeration cycle is directly calculated from the OGCC diagram. This is a convenient tool for calculation of exergy losses and can be used to compute the enclosed areas between the OGCC and the condenser/evaporator horizontal lines. The enclosed areas show that exergy loss for 3-stage compression is much less than that in the 1-stage cycle. Also, for the throttling valve, the exergy loss in the 3-stage refrigeration is considerably less than that in the 1-stage cycle. The new linear curves can easily be plotted and implemented to show the share of inefficiencies occurring in different unit operations.https://www.cetjournal.it/index.php/cet/article/view/10524
spellingShingle M. Hassan Panjeshahi
Nassim Tahouni
Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes
Chemical Engineering Transactions
title Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes
title_full Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes
title_fullStr Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes
title_full_unstemmed Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes
title_short Development of a New Graphical Tool for Calculation of Exergy Losses in Sub-Ambient Processes
title_sort development of a new graphical tool for calculation of exergy losses in sub ambient processes
url https://www.cetjournal.it/index.php/cet/article/view/10524
work_keys_str_mv AT mhassanpanjeshahi developmentofanewgraphicaltoolforcalculationofexergylossesinsubambientprocesses
AT nassimtahouni developmentofanewgraphicaltoolforcalculationofexergylossesinsubambientprocesses