Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum
We show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis dama...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-06-01
|
Series: | JACC: Case Reports |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2666084923001936 |
_version_ | 1827942094507868160 |
---|---|
author | Shumpei Mori, MD, PhD Olcay Aksoy, MD Duc H. Do, MD, MS Ravi H. Dave, MD Kalyanam Shivkumar, MD, PhD |
author_facet | Shumpei Mori, MD, PhD Olcay Aksoy, MD Duc H. Do, MD, MS Ravi H. Dave, MD Kalyanam Shivkumar, MD, PhD |
author_sort | Shumpei Mori, MD, PhD |
collection | DOAJ |
description | We show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis damage during transcatheter aortic valve replacement. (Level of Difficulty: Advanced.) |
first_indexed | 2024-03-13T09:54:31Z |
format | Article |
id | doaj.art-550e99a1efcc44298981da61e5fdec42 |
institution | Directory Open Access Journal |
issn | 2666-0849 |
language | English |
last_indexed | 2024-03-13T09:54:31Z |
publishDate | 2023-06-01 |
publisher | Elsevier |
record_format | Article |
series | JACC: Case Reports |
spelling | doaj.art-550e99a1efcc44298981da61e5fdec422023-05-24T04:21:04ZengElsevierJACC: Case Reports2666-08492023-06-0116101888Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous SeptumShumpei Mori, MD, PhD0Olcay Aksoy, MD1Duc H. Do, MD, MS2Ravi H. Dave, MD3Kalyanam Shivkumar, MD, PhD4UCLA Cardiac Arrhythmia Center, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USA; Address for correspondence: Dr. Shumpei Mori, UCLA Cardiac Arrhythmia Center, UCLA Health System, David Geffen School of Medicine at UCLA, Center of Health Sciences, Suite 46-119C, 650 Charles E. Young Drive South, Los Angeles, California 90095, USA.UCLA Cardiovascular Interventional Programs, David Geffen School of Medicine at UCLA and UCLA Health System, Los Angeles, California, USAUCLA Cardiac Arrhythmia Center, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USAUCLA Cardiovascular Interventional Programs, David Geffen School of Medicine at UCLA and UCLA Health System, Los Angeles, California, USAUCLA Cardiac Arrhythmia Center, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USA; UCLA Cardiovascular Interventional Programs, David Geffen School of Medicine at UCLA and UCLA Health System, Los Angeles, California, USAWe show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis damage during transcatheter aortic valve replacement. (Level of Difficulty: Advanced.)http://www.sciencedirect.com/science/article/pii/S2666084923001936atrioventricular conduction axiscomputed tomographymembranous septumtranscatheter aortic valve replacementvirtual basal ring |
spellingShingle | Shumpei Mori, MD, PhD Olcay Aksoy, MD Duc H. Do, MD, MS Ravi H. Dave, MD Kalyanam Shivkumar, MD, PhD Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum JACC: Case Reports atrioventricular conduction axis computed tomography membranous septum transcatheter aortic valve replacement virtual basal ring |
title | Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum |
title_full | Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum |
title_fullStr | Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum |
title_full_unstemmed | Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum |
title_short | Transcatheter Aortic Valve Replacement Guided by Preprocedural Simulation of Fluoroscopic Location of the Membranous Septum |
title_sort | transcatheter aortic valve replacement guided by preprocedural simulation of fluoroscopic location of the membranous septum |
topic | atrioventricular conduction axis computed tomography membranous septum transcatheter aortic valve replacement virtual basal ring |
url | http://www.sciencedirect.com/science/article/pii/S2666084923001936 |
work_keys_str_mv | AT shumpeimorimdphd transcatheteraorticvalvereplacementguidedbypreproceduralsimulationoffluoroscopiclocationofthemembranousseptum AT olcayaksoymd transcatheteraorticvalvereplacementguidedbypreproceduralsimulationoffluoroscopiclocationofthemembranousseptum AT duchdomdms transcatheteraorticvalvereplacementguidedbypreproceduralsimulationoffluoroscopiclocationofthemembranousseptum AT ravihdavemd transcatheteraorticvalvereplacementguidedbypreproceduralsimulationoffluoroscopiclocationofthemembranousseptum AT kalyanamshivkumarmdphd transcatheteraorticvalvereplacementguidedbypreproceduralsimulationoffluoroscopiclocationofthemembranousseptum |