Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters
A study on the capacity increase of a power converter according to the increase in the single capacity of wave energy converters and four-leg topology that can supply stable power even under unbalanced load conditions during independent operation is required. Therefore, in this paper, the performanc...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-04-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/15/8/2839 |
_version_ | 1797434789188337664 |
---|---|
author | Chan Roh |
author_facet | Chan Roh |
author_sort | Chan Roh |
collection | DOAJ |
description | A study on the capacity increase of a power converter according to the increase in the single capacity of wave energy converters and four-leg topology that can supply stable power even under unbalanced load conditions during independent operation is required. Therefore, in this paper, the performances of various four-leg inverters, from two-level inverters to three-level inverters, which are used as power converters for wave energy converters, are compared respectively. Since the four-leg converter has an unusual structure, the performance of each four-leg inverter was analyzed by applying the model predictive control that can easily and simply configure the controller. To verify the performance of each four-leg inverter, a comparison was performed under balanced load and unbalanced load conditions. Based on this, a suitable four-leg topology of the power converter for wave energy converters was confirmed. |
first_indexed | 2024-03-09T10:38:37Z |
format | Article |
id | doaj.art-55498c8f791f4e6bbc201f0529d278c1 |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-03-09T10:38:37Z |
publishDate | 2022-04-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-55498c8f791f4e6bbc201f0529d278c12023-12-01T20:49:01ZengMDPI AGEnergies1996-10732022-04-01158283910.3390/en15082839Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy ConvertersChan Roh0Department of Energy Engineering, In-je University, 197 Inje-ro, Gimhae-si 50834, KoreaA study on the capacity increase of a power converter according to the increase in the single capacity of wave energy converters and four-leg topology that can supply stable power even under unbalanced load conditions during independent operation is required. Therefore, in this paper, the performances of various four-leg inverters, from two-level inverters to three-level inverters, which are used as power converters for wave energy converters, are compared respectively. Since the four-leg converter has an unusual structure, the performance of each four-leg inverter was analyzed by applying the model predictive control that can easily and simply configure the controller. To verify the performance of each four-leg inverter, a comparison was performed under balanced load and unbalanced load conditions. Based on this, a suitable four-leg topology of the power converter for wave energy converters was confirmed.https://www.mdpi.com/1996-1073/15/8/2839four-leg invertermodel predictive controlbalanced loadunbalanced loadwave energy converter |
spellingShingle | Chan Roh Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters Energies four-leg inverter model predictive control balanced load unbalanced load wave energy converter |
title | Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters |
title_full | Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters |
title_fullStr | Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters |
title_full_unstemmed | Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters |
title_short | Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters |
title_sort | performance comparisons of three phase four wire model predictive control based dc ac inverters capable of asymmetric operation for wave energy converters |
topic | four-leg inverter model predictive control balanced load unbalanced load wave energy converter |
url | https://www.mdpi.com/1996-1073/15/8/2839 |
work_keys_str_mv | AT chanroh performancecomparisonsofthreephasefourwiremodelpredictivecontrolbaseddcacinverterscapableofasymmetricoperationforwaveenergyconverters |