GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection

Gas chromatography-electroantennographic detection (GC-EAD), typically combined with a flame ionization detector (FID), is a widely used technique for studying insect semiochemicals. Combining mass spectrometry (MS) with GC-EAD is extremely beneficial, but has seldom been adopted, possibly due to th...

Full description

Bibliographic Details
Main Authors: Adam Shuttleworth, Steven D. Johnson
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-12-01
Series:Frontiers in Ecology and Evolution
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fevo.2022.1042732/full
_version_ 1811314531386785792
author Adam Shuttleworth
Steven D. Johnson
author_facet Adam Shuttleworth
Steven D. Johnson
author_sort Adam Shuttleworth
collection DOAJ
description Gas chromatography-electroantennographic detection (GC-EAD), typically combined with a flame ionization detector (FID), is a widely used technique for studying insect semiochemicals. Combining mass spectrometry (MS) with GC-EAD is extremely beneficial, but has seldom been adopted, possibly due to the practical challenges associated with incorporating an MS (under vacuum) into a GC-EAD system. We describe a novel method of incorporating MS into a GC-EAD system, where the FID is maintained in the system rather than being replaced by an MS. With this method, effluent is still split between EAD and FID, with the FID being used to assign components that elicit antennal responses, as in a normal GC-FID/EAD system. The MS is introduced via a second effluent splitter inserted before the split between the EAD and the FID. This method allows for EAD, FID, and MS data to be obtained from a single injection, which is especially useful for analysis of thermally desorbed and solid-phase microextraction (SPME) samples. This configuration is also relatively simple to implement and resolves some of the practical challenges associated with dividing effluent between a detector at atmospheric pressure (a live antenna) and a detector under vacuum (the MS). We present test runs with hawkmoth antennae and floral volatiles to demonstrate the effectiveness of this system, and discuss the challenges and practical solutions to incorporating MS into a GC-EAD system that retains an FID detector.
first_indexed 2024-04-13T11:14:17Z
format Article
id doaj.art-5557817470d64227ad41cb7adea9108a
institution Directory Open Access Journal
issn 2296-701X
language English
last_indexed 2024-04-13T11:14:17Z
publishDate 2022-12-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Ecology and Evolution
spelling doaj.art-5557817470d64227ad41cb7adea9108a2022-12-22T02:49:02ZengFrontiers Media S.A.Frontiers in Ecology and Evolution2296-701X2022-12-011010.3389/fevo.2022.10427321042732GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detectionAdam ShuttleworthSteven D. JohnsonGas chromatography-electroantennographic detection (GC-EAD), typically combined with a flame ionization detector (FID), is a widely used technique for studying insect semiochemicals. Combining mass spectrometry (MS) with GC-EAD is extremely beneficial, but has seldom been adopted, possibly due to the practical challenges associated with incorporating an MS (under vacuum) into a GC-EAD system. We describe a novel method of incorporating MS into a GC-EAD system, where the FID is maintained in the system rather than being replaced by an MS. With this method, effluent is still split between EAD and FID, with the FID being used to assign components that elicit antennal responses, as in a normal GC-FID/EAD system. The MS is introduced via a second effluent splitter inserted before the split between the EAD and the FID. This method allows for EAD, FID, and MS data to be obtained from a single injection, which is especially useful for analysis of thermally desorbed and solid-phase microextraction (SPME) samples. This configuration is also relatively simple to implement and resolves some of the practical challenges associated with dividing effluent between a detector at atmospheric pressure (a live antenna) and a detector under vacuum (the MS). We present test runs with hawkmoth antennae and floral volatiles to demonstrate the effectiveness of this system, and discuss the challenges and practical solutions to incorporating MS into a GC-EAD system that retains an FID detector.https://www.frontiersin.org/articles/10.3389/fevo.2022.1042732/fullElectroantennographyfloral volatileGC-MS-EADGC-MS/EADGC-FID-EADGC-FID/EAD
spellingShingle Adam Shuttleworth
Steven D. Johnson
GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection
Frontiers in Ecology and Evolution
Electroantennography
floral volatile
GC-MS-EAD
GC-MS/EAD
GC-FID-EAD
GC-FID/EAD
title GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection
title_full GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection
title_fullStr GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection
title_full_unstemmed GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection
title_short GC-MS/FID/EAD: A method for combining mass spectrometry with gas chromatography-electroantennographic detection
title_sort gc ms fid ead a method for combining mass spectrometry with gas chromatography electroantennographic detection
topic Electroantennography
floral volatile
GC-MS-EAD
GC-MS/EAD
GC-FID-EAD
GC-FID/EAD
url https://www.frontiersin.org/articles/10.3389/fevo.2022.1042732/full
work_keys_str_mv AT adamshuttleworth gcmsfideadamethodforcombiningmassspectrometrywithgaschromatographyelectroantennographicdetection
AT stevendjohnson gcmsfideadamethodforcombiningmassspectrometrywithgaschromatographyelectroantennographicdetection