Deformation induced martensite characterization in Fe-30%Ni-5%Cu alloy

Deformation induced martensite properties were examined according to existing martensite morphology, crystallography and formation temperatures for different prior austenite homogenization conditions in Fe-30%Ni-5%Cu alloy. Scanning electron microscope (SEM), differential scanning calorimetry (DS...

Full description

Bibliographic Details
Main Authors: Güler E., Güler M.
Format: Article
Language:English
Published: Technical Faculty, Bor 2012-01-01
Series:Journal of Mining and Metallurgy. Section B: Metallurgy
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1450-5339/2012/1450-53391200019G.pdf
Description
Summary:Deformation induced martensite properties were examined according to existing martensite morphology, crystallography and formation temperatures for different prior austenite homogenization conditions in Fe-30%Ni-5%Cu alloy. Scanning electron microscope (SEM), differential scanning calorimetry (DSC) and X-ray diffraction (XRD) techniques were employed to investigation. Scanning electron microscope observations showed elongated deformation induced martensite morphology in the austenite phase of alloy. As well, after deformation martensite start temperatures (Ms) were determined as -101°C and -105°C from DSC measurements for different homogenization conditions. In addition, X-ray diffraction analysis revealed the face centred cubic (fcc) of austenite phases and body centred cubic (bcc) deformation induced martensite phases for all studied samples.