Practical Application of a New Cuffless Blood Pressure Measurement Method

It would be useful to develop a reliable method for the cuffless measurement of blood pressure (BP), as such a method could be made available anytime and anywhere for the effective screening and monitoring of arterial hypertension. The purpose of this study is to evaluate blood pressure measurements...

Full description

Bibliographic Details
Main Authors: Nana Gogiberidze, Aleksandr Suvorov, Elizaveta Sultygova, Zhanna Sagirova, Natalia Kuznetsova, Daria Gognieva, Petr Chomakhidze, Victor Frolov, Aleksandra Bykova, Dinara Mesitskaya, Alena Novikova, Danila Kondakov, Alexey Volovchenko, Stefano Omboni, Philippe Kopylov
Format: Article
Language:English
Published: MDPI AG 2023-12-01
Series:Pathophysiology
Subjects:
Online Access:https://www.mdpi.com/1873-149X/30/4/42
_version_ 1797379708722085888
author Nana Gogiberidze
Aleksandr Suvorov
Elizaveta Sultygova
Zhanna Sagirova
Natalia Kuznetsova
Daria Gognieva
Petr Chomakhidze
Victor Frolov
Aleksandra Bykova
Dinara Mesitskaya
Alena Novikova
Danila Kondakov
Alexey Volovchenko
Stefano Omboni
Philippe Kopylov
author_facet Nana Gogiberidze
Aleksandr Suvorov
Elizaveta Sultygova
Zhanna Sagirova
Natalia Kuznetsova
Daria Gognieva
Petr Chomakhidze
Victor Frolov
Aleksandra Bykova
Dinara Mesitskaya
Alena Novikova
Danila Kondakov
Alexey Volovchenko
Stefano Omboni
Philippe Kopylov
author_sort Nana Gogiberidze
collection DOAJ
description It would be useful to develop a reliable method for the cuffless measurement of blood pressure (BP), as such a method could be made available anytime and anywhere for the effective screening and monitoring of arterial hypertension. The purpose of this study is to evaluate blood pressure measurements through a CardioQVARK device in clinical practice in different patient groups. Methods: This study involved 167 patients aged 31 to 88 years (mean 64.2 ± 7.8 years) with normal blood pressure, high blood pressure, and compensated high blood pressure. During each session, three routine blood pressure measurements with intervals of 30 s were taken using a sphygmomanometer with an appropriate cuff size, and the mean value was selected for comparison. The measurements were carried out by two observers trained at the same time with a reference sphygmomanometer using a Y-shaped connector. In the minute following the last cuff-based measurements, an electrocardiogram (ECG) with an I-lead and a photoplethysmocardiogram were recorded simultaneously for 3 min with the CardioQVARK device. We compared the systolic and diastolic BP obtained from a cuff-based mercury sphygmomanometer and smartphone-case-based BP device: the CardioQVARK monitor. A statistical analysis plan was developed using the IEEE Standard for Wearable Cuffless Blood Pressure Devices. Bland–Altman plots were used to estimate the precision of cuffless measurements. Results: The mean difference between the values defined by CardioQVARK and the cuff-based sphygmomanometer for systolic blood pressure (SBP) was 0.31 ± 3.61, while that for diastolic blood pressure (DBP) was 0.44 ± 3.76. The mean absolute difference (MAD) for SBP was 3.44 ± 2.5 mm Hg, and that for DBP was 3.21 ± 2.82 mm Hg. In the subgroups, the smallest error (less than 3 mm Hg) was observed in the prehypertension group, with a slightly larger error (up to 4 mm Hg) found among patients with a normal blood pressure and stage 1 hypertension. The largest error was found in the stage 2 hypertension group (4–5.5 mm Hg). The largest error was 4.2 mm Hg in the high blood pressure group. We, therefore, did not record an error in excess of 7 mmHg, the upper boundary considered acceptable in the IEEE recommendations. We also did not reach a mean error of 5 mmHg, the upper boundary considered acceptable according to the very recent ESH recommendations. At the same time, in all groups of patients, the systolic blood pressure was determined with an error of less than 5 mm Hg in more than 80% of patients. While this study shows that the CardioQVARK device meets the standards of IEEE, the Bland–Altman analysis indicates that the cuffless measurement of diastolic blood pressure has significant bias. The difference was very small and unlikely to be of clinical relevance for the individual patient, but it may well have epidemiological relevance on a population level. Therefore, the CardioQVARK device, while being worthwhile for monitoring patients over time, may not be suitable for screening purposes. Cuffless blood pressure measurement devices are emerging as a convenient and tolerable alternative to cuff-based devices. However, there are several limitations to cuffless blood pressure measurement devices that should be considered. For instance, this study showed a high proportion of measurements with a measurement error of <5 mmHg, while detecting a small, although statistically significant, bias in the measurement of diastolic blood pressure. This suggests that this device may not be suitable for screening purposes. However, its value for monitoring BP over time is confirmed. Furthermore, and most importantly, the easy measurement method and the device portability (integrated in a smartphone) may increase the self-awareness of hypertensive patients and, potentially, lead to an improved adherence to their treatment. Conclusion: The cuffless blood pressure technology developed in this study was tested in accordance with the IEEE protocol and showed great precision in patient groups with different blood pressure ranges. This approach, therefore, has the potential to be applied in clinical practice.
first_indexed 2024-03-08T20:26:54Z
format Article
id doaj.art-5589f026c6154c999c7f62ea6251bb94
institution Directory Open Access Journal
issn 1873-149X
language English
last_indexed 2024-03-08T20:26:54Z
publishDate 2023-12-01
publisher MDPI AG
record_format Article
series Pathophysiology
spelling doaj.art-5589f026c6154c999c7f62ea6251bb942023-12-22T14:31:08ZengMDPI AGPathophysiology1873-149X2023-12-0130458659810.3390/pathophysiology30040042Practical Application of a New Cuffless Blood Pressure Measurement MethodNana Gogiberidze0Aleksandr Suvorov1Elizaveta Sultygova2Zhanna Sagirova3Natalia Kuznetsova4Daria Gognieva5Petr Chomakhidze6Victor Frolov7Aleksandra Bykova8Dinara Mesitskaya9Alena Novikova10Danila Kondakov11Alexey Volovchenko12Stefano Omboni13Philippe Kopylov14Department of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaWorld-Class Research Center “Digital Biodesign and Personalized Healthcare”, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaWorld-Class Research Center “Digital Biodesign and Personalized Healthcare”, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaWorld-Class Research Center “Digital Biodesign and Personalized Healthcare”, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaMedical Center for Premorbid and Emergency Conditions, P.V. Mandryka Central Military Clinical Hospital, 121002 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaDepartment of Cardiology, Functional and Ultrasound Diagnostics of N.V. Sklifosovsky Institute for Clinical Medicine, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, RussiaIt would be useful to develop a reliable method for the cuffless measurement of blood pressure (BP), as such a method could be made available anytime and anywhere for the effective screening and monitoring of arterial hypertension. The purpose of this study is to evaluate blood pressure measurements through a CardioQVARK device in clinical practice in different patient groups. Methods: This study involved 167 patients aged 31 to 88 years (mean 64.2 ± 7.8 years) with normal blood pressure, high blood pressure, and compensated high blood pressure. During each session, three routine blood pressure measurements with intervals of 30 s were taken using a sphygmomanometer with an appropriate cuff size, and the mean value was selected for comparison. The measurements were carried out by two observers trained at the same time with a reference sphygmomanometer using a Y-shaped connector. In the minute following the last cuff-based measurements, an electrocardiogram (ECG) with an I-lead and a photoplethysmocardiogram were recorded simultaneously for 3 min with the CardioQVARK device. We compared the systolic and diastolic BP obtained from a cuff-based mercury sphygmomanometer and smartphone-case-based BP device: the CardioQVARK monitor. A statistical analysis plan was developed using the IEEE Standard for Wearable Cuffless Blood Pressure Devices. Bland–Altman plots were used to estimate the precision of cuffless measurements. Results: The mean difference between the values defined by CardioQVARK and the cuff-based sphygmomanometer for systolic blood pressure (SBP) was 0.31 ± 3.61, while that for diastolic blood pressure (DBP) was 0.44 ± 3.76. The mean absolute difference (MAD) for SBP was 3.44 ± 2.5 mm Hg, and that for DBP was 3.21 ± 2.82 mm Hg. In the subgroups, the smallest error (less than 3 mm Hg) was observed in the prehypertension group, with a slightly larger error (up to 4 mm Hg) found among patients with a normal blood pressure and stage 1 hypertension. The largest error was found in the stage 2 hypertension group (4–5.5 mm Hg). The largest error was 4.2 mm Hg in the high blood pressure group. We, therefore, did not record an error in excess of 7 mmHg, the upper boundary considered acceptable in the IEEE recommendations. We also did not reach a mean error of 5 mmHg, the upper boundary considered acceptable according to the very recent ESH recommendations. At the same time, in all groups of patients, the systolic blood pressure was determined with an error of less than 5 mm Hg in more than 80% of patients. While this study shows that the CardioQVARK device meets the standards of IEEE, the Bland–Altman analysis indicates that the cuffless measurement of diastolic blood pressure has significant bias. The difference was very small and unlikely to be of clinical relevance for the individual patient, but it may well have epidemiological relevance on a population level. Therefore, the CardioQVARK device, while being worthwhile for monitoring patients over time, may not be suitable for screening purposes. Cuffless blood pressure measurement devices are emerging as a convenient and tolerable alternative to cuff-based devices. However, there are several limitations to cuffless blood pressure measurement devices that should be considered. For instance, this study showed a high proportion of measurements with a measurement error of <5 mmHg, while detecting a small, although statistically significant, bias in the measurement of diastolic blood pressure. This suggests that this device may not be suitable for screening purposes. However, its value for monitoring BP over time is confirmed. Furthermore, and most importantly, the easy measurement method and the device portability (integrated in a smartphone) may increase the self-awareness of hypertensive patients and, potentially, lead to an improved adherence to their treatment. Conclusion: The cuffless blood pressure technology developed in this study was tested in accordance with the IEEE protocol and showed great precision in patient groups with different blood pressure ranges. This approach, therefore, has the potential to be applied in clinical practice.https://www.mdpi.com/1873-149X/30/4/42blood pressurecufflessblood pressure measurementportable ECG monitorCardioQVARK devicetelemedicine
spellingShingle Nana Gogiberidze
Aleksandr Suvorov
Elizaveta Sultygova
Zhanna Sagirova
Natalia Kuznetsova
Daria Gognieva
Petr Chomakhidze
Victor Frolov
Aleksandra Bykova
Dinara Mesitskaya
Alena Novikova
Danila Kondakov
Alexey Volovchenko
Stefano Omboni
Philippe Kopylov
Practical Application of a New Cuffless Blood Pressure Measurement Method
Pathophysiology
blood pressure
cuffless
blood pressure measurement
portable ECG monitor
CardioQVARK device
telemedicine
title Practical Application of a New Cuffless Blood Pressure Measurement Method
title_full Practical Application of a New Cuffless Blood Pressure Measurement Method
title_fullStr Practical Application of a New Cuffless Blood Pressure Measurement Method
title_full_unstemmed Practical Application of a New Cuffless Blood Pressure Measurement Method
title_short Practical Application of a New Cuffless Blood Pressure Measurement Method
title_sort practical application of a new cuffless blood pressure measurement method
topic blood pressure
cuffless
blood pressure measurement
portable ECG monitor
CardioQVARK device
telemedicine
url https://www.mdpi.com/1873-149X/30/4/42
work_keys_str_mv AT nanagogiberidze practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT aleksandrsuvorov practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT elizavetasultygova practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT zhannasagirova practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT nataliakuznetsova practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT dariagognieva practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT petrchomakhidze practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT victorfrolov practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT aleksandrabykova practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT dinaramesitskaya practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT alenanovikova practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT danilakondakov practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT alexeyvolovchenko practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT stefanoomboni practicalapplicationofanewcufflessbloodpressuremeasurementmethod
AT philippekopylov practicalapplicationofanewcufflessbloodpressuremeasurementmethod