Seismic Response Comparisons of Prefabricated and Cast In Situ Subway Station Structures in Liquefiable Site
Based on the engineering practice of the first prefabricated subway station (Shuangfeng Station) in Changchun, China, the applicability of prefabricated subway station structures (PSSSs) in liquefiable sites in seismically defended areas is investigated. In this paper, the finite difference software...
Main Authors: | Junhai An, Qiaofeng Liu, Yanhua Zhang, Xuehui Zhang |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-12-01
|
Series: | Buildings |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-5309/13/12/3071 |
Similar Items
-
Response Displacement Method for Seismic Calculation of Subway Station Complex Structure of TOD Mode
by: Junhai An, et al.
Published: (2023-11-01) -
Effect of Entrance Frame on Crack Development around Prefabricated Subway Station Openings
by: Zhenze Mo, et al.
Published: (2023-04-01) -
Numerical analysis on the seismic performance of subway station reinforced by ECC-BFRP
by: Chenhao Ren, et al.
Published: (2024-07-01) -
Seismic performance of two-story subway station structures with different isolating systems
by: Haiyang Zhuang, et al.
Published: (2022-10-01) -
Case study on the seismic response of a subway station combined with a flyover
by: Qi Wang, et al.
Published: (2021-12-01)